SHOWER READY FUNCTION

SHOWER READY FUNCTION For model equipped with user interface type shown in figure 9 The product is equipped with an intelligent function to minimise water heating time. Regardless of the tem perature set by the user, the symbol " " shower ready will turn on as soon as there is enough hot water for at least one shower (40 litres of mixed hot water at 40 °C). ANTI-FREEZE FUNCTION The anti-freeze function is the appliances automatic protection to avoid damages caused by very low tempe ratures below 5 °C, in the event in which the product is turned off during winter. It is recommended that the product remains plugged in to the mains power, even if is inactive for a long time. THERMAL DISINFECTION FUNCTION (Anti-Legionella) The Anti-Legionella function is activated by default. It consists of a water heating/60°C temperature mainte nance cycle for 1 hour which has a thermal disinfection action on the relative bacteria. The cycle starts when the product is started up and when it is restarted after a power outage. If the product always functions at temperatures lower than 55°C, the cycle is repeated after 30 days. When the product is switched off, the anti-Legionella function is deactivated. If the equipment is switched off during the anti Legionella cycle, the product switches off and the function is deactivated. At the end of the cycle, the use temperature returns to the temperature previously set by the user. The activation of the anti-legionella cycle appears as a normal temperature adjustment 60°C. Activate this function by pressing and holding both the “ECO” and “+” buttons for 4 s.; once activation is confi rmed, the LED (Ref. 4) will fl ash quickly for 4 s. Permanently deactivate the function by repeating the above steps; once the deactivation is confi rmed, LED 40°c (Ref. 1) will fl ash quickly for 4 s. RESET/DIAGNOSTICS For models equipped with user interface type shown in figure 9 When one of the malfunctions described above occurs, the appliance will enter its “fault status” and all LEDs on the control panel will fl ash simultaneously. Diagnostics: to enable the diagnostic function, press contemporary ON-OFF button (ref. A) and MINUS button for 3 sec. The type of fault is indicated by fi ve LEDs (Ref. 1-5) according to the following scheme: LED Ref. 1 - internal malfunction of the circuit board LED Ref. 1 and 3 - internal malfunction of the circuit board (NFC communication or NFC data) LED Ref. 3 - broken temperature probes (open or short circuited) - boiler outlet LED Ref. 5 - excessive water temperature detected by single sensor - boiler outlet LED Ref. 4 and 5 - general excessive water temperature (circuit board fault) - boiler outlet LED Ref. 3 and 4 - Failure to heat water with powered heating element - boiler outlet LED Ref. 3, 4 and 5 - overheating caused by lack of water - boiler outlet LED Ref. 2 and 3 - broken temperature probes (open or short circuited) - boiler inlet LED Ref. 2 and 5 - excessive water temperature detected by single sensor - boiler inlet LED Ref. 2, 4 and 5 - general excessive water temperature (circuit board fault) - boiler inlet LED Ref. 2, 3 and 4 - failure to heat water with powered heating element - boiler inlet LED Ref. 2, 3, 4 and 5 - overheating caused by lack of water - boiler inlet Exit the diagnostic function by pressing the ON/OFF button (Ref. A) or wait for 25 seconds. 16 / EN

WI-FI FUNCTION For models equipped with user interface type shown in figure 10 For detailed information on the Wi-Fi confi guration and product registration procedure refer to the enclosed, dedicated connectivity Quick Start Guide. Account creation, figure 11 • First download and install the dedicated App on your mobile phone (App name can be found in the quick start guide). • Open the APP and click on SIGN UP; Fill in the fi elds. • Open the registration reply message received in your mailbox and click on the link to activate the user account WI-FI configuration, figure 12 • Press the Wi-Fi Button on the product’s control panel to activate the Wi-Fi (Wi-Fi button will blink slow). • Press the Wi-Fi Button again for 5 seconds on the product’s control panel to create the Access Point (Wi-Fi button will blink fast). • Log in to Aqua Ariston NET App and follow the wizard to connect and register your product. Procedure completed, figure 13 The connection is successful when: • The wi-fi button is steady on. • The app shows the successful registration message If the connection fails, carefully check and repeat the above steps. Note: the password cannot be Chinese characters. If there are any Chinese characters, please modify it. App layout, figure 14 The following instructions are included: • Following functions are included: • On/off (A) • Manual mode (B) • Program mode (C) • ECO mode (D) • POWER (E) • Knob to select temperature(F) • Remaining time (G) • Number of showers (H) Connection status description WiFi Blinking slow Button Blinking Fast Steady on Off The Wi-Fi is connected to the home network The Wi-Fi module is on Access Point mode The Wi-Fi module is ON and Connected to the home network The Wi-Fi module is OFF 17 / EN

MANUALS