PRIMO HE ITD 100-125-150-175-200-250-300 PRIMO HE ITI 100-125-150-175-200-250-300 PRIMO HE ITSI 210-250-300 tABle 1 Model Storage Units Pipe Size Coil Dimensions in mm Weight Surface When Full Capacity m 2 Kg Inlet Outlet A B C D E F G H I J Direct rAnGe PRIMO HE ITD 125 PRIMO HE ITD 150 PRIMO HE ITD 210 PRIMO HE ITD 300 125 l 150 l 200 l 300 l 3/4” Male 3/4” Male 3/4” Male 3/4” Male - - - - 666 806 956 1199 763 921 1237 1540 1024 1182 1498 1792 - - - - - - - - 550 550 550 600 281 281 281 259 - - - - - - - - - - - - 156 183 239 344 inDirect rAnGe PRIMO HE ITI 100 PRIMO HE ITI 125 PRIMO HE ITI 150 PRIMO HE ITI 210 PRIMO HE ITI 250 PRIMO HE ITI 300 100l 125l 150l 200l 250l 300l 3/4” Male 3/4” Male 3/4” Male 3/4” Male 3/4” Male 3/4” Male 0.5 0.67 0.80 0.90 0.90 0.90 508 666 806 956 964 1199 605 763 921 1237 1305 1540 863 1024 1182 1498 1600 1792 571 641 781 781 784 784 - - - - - - 550 550 550 550 600 600 281 281 281 281 259 259 241 241 241 241 244 244 - - - - - - - - - - - - 128 160 187 248 305 361 twin coil rAnGe PRIMO HE ITSI 210 (top/bottom) PRIMO HE ITSI 250 (top/bottom) PRIMO HE ITSI 300 (top/bottom) 200l 250l 300l 3/4” Male 3/4” Male 3/4” Male 0.67/0.67 0.67/0.67 0.67/0.89 956 964 1199 1237 1305 1540 1498 1600 1792 641 644 784 - - - 550 600 600 281 259 259 241 244 244 822 865 1100 1222 1265 1500 253 310 366 8
3.8 connection oF MAins wAter supply For floor standing models: On the front of the unit there is a label to identify the connection ports. Please check this before making any connection to the unit. For units up to 300 litres it is recommended that all mains cold water supply pipe work is a minimum of 22mm, with the exception of model ST 50 ProTech where 15mm can be used. For 500 litre models the supply should be 28mm. An isolating valve should be installed between the cold water supply and the cylinder for servicing. ALL PIPEWORK MUST BE FLUSHED TO AVOID DAMAGE TO THE CONTROL VALVES. Please refer to FiGs. 3.1 - 3.7 for a suggested installation layout. Draining taps must be located in acessible postions to permit the draining of the whole cylinder. The taps must be a minimal size of at least 15mm nominal size (preferably 22mm), and manufactured in accordance with BS 2879:1980. When installing the expansion vessel it can either be connected directly to the combination valve (see Figs 3.8 - 3.10), or it can be installed remotely using the flexible hose supplied. iMportAnt note:- When installing the expansion vessel, Do not install the expansion vessel vertically as air can become trapped in the expansion vessel resulting in potential vibrations through the cylinder and pipework. When using the flexible hose to remotely install the expansion vessel away from the control valve, again, ensure that the vessel is not installed in a vertical position where it can trap air. See below for acceptable installation practices. ✘ ✔ ✘ ✔ 9
Loading...
Loading...
CATALOGUE
PRODUCT BROCHURES
DATASHEETS
MANUALS
MANUALS (DISCONTINUED)
PLANNER MANUALS
CASE STUDIES