3.6 sitinG AnD FixinG A

3.6 sitinG AnD FixinG A minimum dynamic pressure of 1.5 bar or 20 litres per minute is required for satisfactory operation. 85% of UK dwellings have a mains pressure above 2.0 bar. note: tHe MAins wAter supply Must not exceeD 16 BAr. The cylinder should be left packed until it is time to install. When unpacking the appliance follow the guidelines within the packaging and take care not to damage the temperature and pressure relief valve. The cylinder may be installed in any convenient position. As it is connected to the mains cold water supply. Consideration must be given to allow ease of access for maintenance purposes. Additionally, do not install the unit in premises which may be subject to freezing. Ensure that the floor load bearing strength is adequate to take the weight of the cylinder when full of water (see tABle 1). e.g. Do not install the cylinder on floors made of chipboard or other flooring where the mechanical strength is compromised when damp. The ST50, ST80 and ST100 ProTech models are wall mounted. All other models are free standing. These are supplied with feet which are attached to the heater via self-tapping screws which are also supplied. All units must be installed in the verticAl position. For maintenance purposes leave at least 500 mm free space in front of the unit, for access. iMportAnt: In the event that the installation of this cylinder wil require a third sensor to be fitted (i.e. Solar) the following actions will be necessary: Replace one of the thermostat pockets supplied with the indirect thermostats in the Unvented Kit with the elongated thermostat pocket also supplied. This thermostat and pocket must now be fitted to the top thermostat connection. Please also refer to Section 2.3 General Guidance options A and B (page 5) of this manual. For further technical advice, please contact the Ariston Technical Advice Line on 0870 241 8180. 6

3.7 overAll DiMensions ST ProTech 50-80-100 Classico HE STD 125-150-200-300 Classico HE STI 125-150-200-300 500 STD ProTech Classico HE STI 500 tABle 1 Model Storage Units Pipe Size Coil Dimensions in mm Weight Surface When Full Capacity m 2 Kg Inlet Outlet A B C D E F G H I J Direct rAnGe Wall-hung 141 ST 100 ProTech 100 l 3/4” - 550 175 700 230 575 560 - - - - 129 Floor Standing Classico HE STD 125 Classico HE STD 150 Classico HE STD 210 Classico HE STD 300 Classico HE STD 500 25 l 150 l 200 l 300 l 500 l 3/4” Male 3/4” Male 3/4” Male 3/4" Male 1” Male - - - - - 666 806 956 1199 1390 763 921 1237 1540 335 1024 1182 1498 1792 1870 - - - - - - - - - - 550 550 550 600 714 281 281 281 259 - - - - - - - - - - - - - - - - 158 190 245 625 166 inDirect rAnGe Classico HE STI 125 Classico HE STI 150 Classico HE STI 210 Classico HE STI 300 Classico HE STI 500 125 l 150 l 200 l 300 l 500 l 3/4” Male 3/4” Male 3/4” Male 3/4” Male 1" Male 0.75 0.9 0.9 0.9 1.5 666 806 956 1199 1390 763 921 1237 1540 335 1024 1182 1498 1792 1870 641 781 781 784 700 - - - - - 550 550 550 600 714 281 281 281 259 - 241 241 241 244 - - - - - - - - - - - 201 256 395 641 7

MANUALS