Commissioning 4 Curing

Commissioning 4 Curing Heating + Functional Heating (screed heating at a variable temperature from 25°C to the temperature defined by Par. 1.12.6 Floor drying Flow Set Point T, according to the period specified as an example in the chart for an 18-day period, then at a fixed temperature of 25°C for a period of 3 days, then for a further 4 days at the temperature defined by Par. 1.12.6 Floor drying Flow Set Point T) Temperature °C 60 50 40 30 20 10 0 0 5 10 15 20 25 30 Period (days) Fig. 56 1.14 ENERGY MANAGER STATISTICS Shows the duration of the system operation in hours. 1.14.1 Heating running hours (h/10) 1.14.2 DHW running hours (h/10) 1.14.6 Cooling running hours (h/10) 5 Manual (screed heating at the temperature set in Par. 1.12.6 Floor drying Flow Set Point T) Press the selector to confirm. 1.12.6 Floor drying Flow Set Point T Defines the set-point temperature of the heating delivery during the screed drying function (see Par. 1.12.5 Floor drying cycle). 1.12.7 Floor drying total Remaining Days Defines the days remaining for the screed drying function. 1.12.9 Exogel kit activation Enables integration of the anti-freeze kit. Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 46 / EN

Commissioning 1.16 EM DIAGNOSTICS - 1 INPUT Displays the values of the system’s board inputs. 1.16.0 Energy Manager status Press the selector . Turn the selector to choose the desired item. 0 Standby. 1 Antifreeze cycle. 2 Heating cycle. 3 Heating temperature reached. 4 DHW cycle. 5 Thermal cleanse function. 6 Air purge function. 7 Chimney function. 8 Floor drying cycle. 9 No heat generation. 10 Manual mode. 11 Fault. 12 Initialization. 13 OFF. 14 Cooling. 15 DHW antifreeze. 16 Photovoltaic integration. 17 Dehumidification. 18 Pump Down. 19 Defrost. 20 Buffer Heating+DHW Serving. 21 Buffer Cooling+DHW Serving. 22 Buffer Heating Serving. 23 Buffer Cooling Serving. 24 Automatic calibration. Press the selector to confirm. 1.16.1 Hydraulic scheme diagnostic Press the selector . Turn the selector to choose the desired item. 0 None. 1 Hybrid combi. 2 Hybrid system. 3 Hybrid system with thermostat. 4 Pacman plus. 5 Pacman flex. 6 Pacman flex with thermostat. 7 Pacman light plus. 8 Pacman light flex. 9 Pacman light flex with thermostat. Press the selector to confirm. 1.17 EM DIAGNOSTICS - 2 INPUT 1.17.0 Room Thermostat 1 Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 1.17.1 Room Thermostat 2 Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 1.17.2 AUX input 1 Press the selector . Turn the selector to choose the desired item. 0 Open. 1 Close. Press the selector to confirm. 1.17.3 AUX input 2 Press the selector . Turn the selector to choose the desired item. 0 Open. 1 Close. Press the selector to confirm. 1.17.4 HV input 1 Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 1.17.5 HV input 2 Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 1.16.2 CH flow set T 1.16.3 CH flow temperature 1.16.5 DHW storage temperature 47 / EN

MANUALS

Views
1 year ago

Nimbus Pocket M NET R32 Installation Manual UK

  • Text
  • Heat pump
  • Selector
  • Heating
  • Desired
  • Outdoor
  • Cooling
  • Electrical
  • Input
  • Buffer
  • Sensor
  • Thermostat
  • Nimbus
  • Installation
  • Manual
  • Wwwaristoncom

Commissioning 4 Curing

Commissioning 4 Curing Heating + Functional Heating (screed heating at a variable temperature from 25°C to the temperature defined by Par. 1.12.6 Floor drying Flow Set Point T, according to the period specified as an example in the chart for an 18-day period, then at a fixed temperature of 25°C for a period of 3 days, then for a further 4 days at the temperature defined by Par. 1.12.6 Floor drying Flow Set Point T) Temperature °C 60 50 40 30 20 10 0 0 5 10 15 20 25 30 Period (days) Fig. 56 1.14 ENERGY MANAGER STATISTICS Shows the duration of the system operation in hours. 1.14.1 Heating running hours (h/10) 1.14.2 DHW running hours (h/10) 1.14.6 Cooling running hours (h/10) 5 Manual (screed heating at the temperature set in Par. 1.12.6 Floor drying Flow Set Point T) Press the selector to confirm. 1.12.6 Floor drying Flow Set Point T Defines the set-point temperature of the heating delivery during the screed drying function (see Par. 1.12.5 Floor drying cycle). 1.12.7 Floor drying total Remaining Days Defines the days remaining for the screed drying function. 1.12.9 Exogel kit activation Enables integration of the anti-freeze kit. Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 46 / EN

Commissioning 1.16 EM DIAGNOSTICS - 1 INPUT Displays the values of the system’s board inputs. 1.16.0 Energy Manager status Press the selector . Turn the selector to choose the desired item. 0 Standby. 1 Antifreeze cycle. 2 Heating cycle. 3 Heating temperature reached. 4 DHW cycle. 5 Thermal cleanse function. 6 Air purge function. 7 Chimney function. 8 Floor drying cycle. 9 No heat generation. 10 Manual mode. 11 Fault. 12 Initialization. 13 OFF. 14 Cooling. 15 DHW antifreeze. 16 Photovoltaic integration. 17 Dehumidification. 18 Pump Down. 19 Defrost. 20 Buffer Heating+DHW Serving. 21 Buffer Cooling+DHW Serving. 22 Buffer Heating Serving. 23 Buffer Cooling Serving. 24 Automatic calibration. Press the selector to confirm. 1.16.1 Hydraulic scheme diagnostic Press the selector . Turn the selector to choose the desired item. 0 None. 1 Hybrid combi. 2 Hybrid system. 3 Hybrid system with thermostat. 4 Pacman plus. 5 Pacman flex. 6 Pacman flex with thermostat. 7 Pacman light plus. 8 Pacman light flex. 9 Pacman light flex with thermostat. Press the selector to confirm. 1.17 EM DIAGNOSTICS - 2 INPUT 1.17.0 Room Thermostat 1 Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 1.17.1 Room Thermostat 2 Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 1.17.2 AUX input 1 Press the selector . Turn the selector to choose the desired item. 0 Open. 1 Close. Press the selector to confirm. 1.17.3 AUX input 2 Press the selector . Turn the selector to choose the desired item. 0 Open. 1 Close. Press the selector to confirm. 1.17.4 HV input 1 Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 1.17.5 HV input 2 Press the selector . Turn the selector to choose the desired item. 0 OFF. 1 ON. Press the selector to confirm. 1.16.2 CH flow set T 1.16.3 CH flow temperature 1.16.5 DHW storage temperature 47 / EN