Commissioning Parameter Description Default (IDU: M) Default (IDU: L) Range - Value 1. 7 Central Heating 1. 7. 1 Boost Time 16min 16min [0 - 60]min 1. 7. 2 FlowT HP Offset 0°C 0°C [0 - 10]°C 1. 8 Cooling 1. 8. 0 Cooling mode activation 0 0 0 = Not active ¦ 1 = Active 1. 8. 2 Cooling FlowT HP Offset 0°C 0°C [-10 - 0]°C 1. 8. 3 Humidity Control Threshold 70% 70% [40 - 100]% 1. 8. 4 Humidity Control Hysteresis 10% 10% [0 - 30]% 1. 9 Domestic hot water 1. 9. 0 DHW comfort setpoint temp. 55°C 55°C [35 - 65]°C 1. 9. 1 DHW reduced setpoint temp. 35°C 35°C [35 - 60]°C 1. 9. 2 Comfort Function 2 2 0 = Disabled ¦ 1 = Time Based ¦ 2 = Always active 1. 9. 3 DHW operation mode 1 1 0 = Standard ¦ 1 = Green ¦ 2 = HC - HP ¦ 3 = HC - HP 40 1. 9. 5 Max HP charging time 120min 120min [30 - 240]min 1. 9. 6 Thermal cleanse function 1 1 0 = OFF ¦ 1 = ON 1. 9. 7 Thermal Cleanse start time [hh:mm] 01:00 01:00 [00:00 - 23:45][hh:mm] 1. 9. 8 Thermal Cleanse Cycle frequency 481h 481h [24 - 481]h 1. 10 Manual Mode - 1 1. 10. 0 Manual mode activation 0 0 0 = OFF ¦ 1 = ON 1. 10. 1 HP circulator control 0 0 0 = OFF ¦ 1 = Low speed ¦ 2 = High speed 1. 10. 2 Diverter valve control 0 0 0 = DHW ¦ 1 = CH 1. 10. 3 Diverter valve COOLING 0 0 0 = CH ¦ 1 = COOLING 1. 10. 4 Auxiliary circulator 0 0 0 = OFF ¦ 1 = ON 1. 10. 5 Test resistance 1 0 0 0 = OFF ¦ 1 = ON 1. 10. 6 Test resistance 2 0 0 0 = OFF ¦ 1 = ON 1. 10. 7 Test resistance 3 0 0 0 = OFF ¦ 1 = ON 1. 10. 8 All output AUX contact 0 0 0 = OFF ¦ 1 = ON 1. 10. 9 Anode output 0 0 0 = OFF ¦ 1 = ON 1. 11 Manual Mode - 2 1. 11. 0 Manual mode activation 0 0 0 = OFF ¦ 1 = ON 1. 11. 1 Force Hp Heat 0 0 0 = OFF ¦ 1 = ON 1. 11. 2 Force Hp Cool 0 0 0 = OFF ¦ 1 = ON 1. 11. 6 Tank electric heater 0 0 0 = OFF ¦ 1 = ON 1. 12 Test & Utilities 1. 12. 0 Air-purge function 0 0 0 = OFF ¦ 1 = ON 1. 12. 1 Antiblocking function enable 1 1 0 = OFF ¦ 1 = ON 1. 12. 2 Quiet mode activation HHP 0 0 0 = OFF ¦ 1 = ON 1. 12. 3 Quiet mode start time HHP [hh:mm] 22:00 22:00 [00:00 - 23:45][hh:mm] 1. 12. 4 Quiet mode end time HHP [hh:mm] 06:00 06:00 [00:00 - 23:45][hh:mm] 1. 12. 5 Floor drying cycle 0 0 1. 12. 6 Floor drying Flow Set Point T 55°C 55°C [25 - 60]°C 1. 12. 7 Floor drying total Remaining Days 1. 12. 9 Exogel kit activation 1 1 0 = OFF ¦ 1 = ON 1. 14 Energy Manager Statistics 1. 14. 1 Heating running hours (h/10) h/10 1. 14. 2 DHW running hours (h/10) h/10 1. 14. 3 Resistor 1 running hours (h/10) h/10 1. 14. 4 Resistor 2 running hours (h/10) h/10 1. 14. 5 Resistor 3 running hours (h/10) h/10 1. 14. 6 Cooling running hours (h/10) h/10 0 = OFF ¦ 1 = Functional Heating ¦ 2 = Curing Heating ¦ 3 = Functional Heating + Curing Heating ¦ 4 = Curing Heating + Functional Heating ¦ 5 = Manual 1. 16 EM diagnostics - 1 input 1. 16. 0 Energy Manager status 0 = Standby ¦ 1 = Antifreeze cycle ¦ 2 = Heating cycle ¦ 3 = Heating temperature reached ¦ 4 = DHW cycle ¦ 5 = Thermal cleanse function ¦ 6 = Air purge function ¦ 7 = Chimney function ¦ 8 = Floor drying cycle ¦ 9 = No heat generation ¦ 10 = Manual mode ¦ 11 = Error ¦ 12 = Initialization ¦ 13 = OFF ¦ 14 = Cool mode ¦ 15 = DHW antifreeze ¦ 16 = Photovoltaic integration ¦ 17 = Dehumidification ¦ 18 = Pump Down ¦ 19 = Defrost ¦ 20 = Buffer Heating+DHW Serving ¦ 21 = Buffer Cooling+DHW Serving ¦ 22 = Buffer Heating Serving ¦ 23 = Buffer Cooling Serving ¦ 24 = Automatic calibration 1. 16. 1 Hydraulic scheme diagnostic 0 = None ¦ 1 = Hybrid combi ¦ 2 = Hybrid system ¦ 3 = Hybrid system with thermostat ¦ 4 = Pacman plus ¦ 5 = Pacman flex ¦ 6 = Pacman flex with thermostat ¦ 7 = Pacman light plus ¦ 8 = Pacman light flex ¦ 9 = Pacman light flex with thermostat 1. 16. 2 CH flow set T °C 1. 16. 3 CH flow temperature °C 1. 16. 5 DHW storage temperature °C 1. 16. 6 Pressure switch 0 0 (visible by setting par. 1.1.7 ≠ 2) 0 = Open ¦ 1 = Close 1. 16. 7 Heating circuit pressure bar (visible with par. 1.1.7 = 2) 60 / EN
Commissioning Parameter Description Default (IDU: M) Default (IDU: L) Range - Value 1. 17 EM diagnostics - 2 input 1. 17. 0 Room Thermostat 1 0 = OFF ¦ 1 = ON 1. 17. 1 Room Thermostat 2 0 = OFF ¦ 1 = ON 1. 17. 2 AUX input 1 0 = Open ¦ 1 = Close 1. 17. 3 AUX input 2 0 = Open ¦ 1 = Close 1. 17. 4 HV input 1 0 = OFF ¦ 1 = ON 1. 17. 5 HV input 2 0 = OFF ¦ 1 = ON 1. 18 EM diagnostics - 1 output 1. 18. 0 Main circulator status 0 = OFF ¦ 1 = ON 1. 18. 1 Tank electric heater 0 = OFF ¦ 1 = ON ¦ 2 = Integration ¦ 3 = Lockout 1. 18. 2 HC Pump 2 0 = OFF ¦ 1 = ON 1. 18. 3 Diverter Valve (CH/DHW) 0 = DHW ¦ 1 = CH 1. 18. 4 Diverter Valve 2 (CH/Cooling) 0 = CH ¦ 1 = COOLING 1. 18. 5 CH backup resistance 1 0 = OFF ¦ 1 = ON 1. 18. 6 CH backup resistance 2 0 = OFF ¦ 1 = ON 1. 18. 7 CH backup resistance 3 0 = OFF ¦ 1 = ON 1. 18. 8 AUX output 1 0 = Open ¦ 1 = Close 1. 18. 9 AUX output 2 0 = Open ¦ 1 = Close 1. 19 Service 1. 19. 0 SW Version main 1. 20 System integration 1. 20. 0 PV offset DHW setpoint temperature 0°C 0°C [0 - 20]°C 1. 20. 2 Tank solar integration 0 0 0 = Absent ¦ 1 = Present 1. 20. 3 OpenTherm gateway activation 0 0 0 = OFF ¦ 1 = ON 1. 21 Error History 1. 21. 0 Last 10 errors 1. 21. 1 Reset error list 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 1. 22 Reset Menu 1. 22. 0 Reset factory settings 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 1. 23 Domestic hot water - 2 1. 23. 0 Thermal Cleanse target temp 60°C 60°C [60 - 70]°C 1. 23. 1 Antilegionella target temperature duration 1h 1h [1 - 2]h 1. 23. 2 Max Duration Antilegionella 6h 6h [4 - 12]h 1. 24 Energy meter 1. 24. 0 Energy pulse unit 0 0 0 = None ¦ 1 = kWh 1. 24. 1 Energy pulse value number 1 1 [1 - 10] 1. 24. 2 Energy pulse value factor 6 6 1. 24. 3 Energy pulse measuring type 1 1 0 = Only HP ¦ 1 = HP + Electric Heater 1. 24. 4 Backup electric heaters nominal power 2kW 2kW [1 - 3]kW 1. 24. 5 Tank electric heaters nominal power 2kW 2kW [1 - 3]kW 1. 24. 6 Backup electric heaters efficiency 95% 95% [0 - 100]% 1. 24. 7 Tank electric heaters efficiency 95% 95% [0 - 100]% 4 Zone 1 parameters 0 = /1000 ¦ 1 = /100 ¦ 2 = /10 ¦ 3 = 1 ¦ 4 = x10 ¦ 5 = x100 ¦ 6 = x1000 4. 0 Setpoint 4. 0. 0 T Day 19°C Heat - 24°C 19°C Heat - 24°C Cool Cool [10 - 30]°C 4. 0. 1 T Night 13°C Heat - 30°C 13°C Heat - 30°C Cool Cool [10 - 30]°C 4. 0. 2 T set Z1 40°C [HT] - 20°C 40°C [HT] - 20°C [LT ] [LT ] [20 - 60]°C 4. 0. 3 Zone frost temperature 5°C 5°C [2 - 15]°C 4. 1 Automatic winter mode 4. 1. 0 Automatic winter mode activation 0 0 0 = OFF ¦ 1 = ON 4. 1. 1 Automatic winter mode threshold 20°C 20°C [0 - 30]°C 4. 1. 2 Automatic winter mode delay time 300min 300min [0 - 600]min 4. 2 Settings 4. 2. 0 Zone temperature range 1 1 (0 = [LT]; 1 = [HT]) 0 = Low Temp ¦ 1 = High Temp 4. 2. 1 Thermoregulation 1 1 0 = Fix Flow T ¦ 1 = Basic Thermoreg ¦ 2 = Room T Only ¦ 3 = Outdoor T Only ¦ 4 = Room+Outdoor T 4. 2. 2 Slope 0.6 [LT] or 1.5 0.6 [LT] or 1.5 [0,2 [LT] or 0,4 [HT] - 1 [LT]or 3,5 [HT]] (visible by setting par [HT] [HT] 4.2.7 = 0) 4. 2. 3 Offset 0°C 0°C [-7 [LT] or -14 [HT] - 7 [LT] or 14[HT]]°C EN / 61
NIMBUS PLUS M NET R32 3301719 33017
Contents 1. Safety advices 1.1
a a a a a a a When connecting the c
Safety advices 1.3 Symbols affixed
Loading...
Loading...
Commissioning Parameter Description Default (IDU: M) Default (IDU: L) Range - Value 1. 7 Central Heating 1. 7. 1 Boost Time 16min 16min [0 - 60]min 1. 7. 2 FlowT HP Offset 0°C 0°C [0 - 10]°C 1. 8 Cooling 1. 8. 0 Cooling mode activation 0 0 0 = Not active ¦ 1 = Active 1. 8. 2 Cooling FlowT HP Offset 0°C 0°C [-10 - 0]°C 1. 8. 3 Humidity Control Threshold 70% 70% [40 - 100]% 1. 8. 4 Humidity Control Hysteresis 10% 10% [0 - 30]% 1. 9 Domestic hot water 1. 9. 0 DHW comfort setpoint temp. 55°C 55°C [35 - 65]°C 1. 9. 1 DHW reduced setpoint temp. 35°C 35°C [35 - 60]°C 1. 9. 2 Comfort Function 2 2 0 = Disabled ¦ 1 = Time Based ¦ 2 = Always active 1. 9. 3 DHW operation mode 1 1 0 = Standard ¦ 1 = Green ¦ 2 = HC - HP ¦ 3 = HC - HP 40 1. 9. 5 Max HP charging time 120min 120min [30 - 240]min 1. 9. 6 Thermal cleanse function 1 1 0 = OFF ¦ 1 = ON 1. 9. 7 Thermal Cleanse start time [hh:mm] 01:00 01:00 [00:00 - 23:45][hh:mm] 1. 9. 8 Thermal Cleanse Cycle frequency 481h 481h [24 - 481]h 1. 10 Manual Mode - 1 1. 10. 0 Manual mode activation 0 0 0 = OFF ¦ 1 = ON 1. 10. 1 HP circulator control 0 0 0 = OFF ¦ 1 = Low speed ¦ 2 = High speed 1. 10. 2 Diverter valve control 0 0 0 = DHW ¦ 1 = CH 1. 10. 3 Diverter valve COOLING 0 0 0 = CH ¦ 1 = COOLING 1. 10. 4 Auxiliary circulator 0 0 0 = OFF ¦ 1 = ON 1. 10. 5 Test resistance 1 0 0 0 = OFF ¦ 1 = ON 1. 10. 6 Test resistance 2 0 0 0 = OFF ¦ 1 = ON 1. 10. 7 Test resistance 3 0 0 0 = OFF ¦ 1 = ON 1. 10. 8 All output AUX contact 0 0 0 = OFF ¦ 1 = ON 1. 10. 9 Anode output 0 0 0 = OFF ¦ 1 = ON 1. 11 Manual Mode - 2 1. 11. 0 Manual mode activation 0 0 0 = OFF ¦ 1 = ON 1. 11. 1 Force Hp Heat 0 0 0 = OFF ¦ 1 = ON 1. 11. 2 Force Hp Cool 0 0 0 = OFF ¦ 1 = ON 1. 11. 6 Tank electric heater 0 0 0 = OFF ¦ 1 = ON 1. 12 Test & Utilities 1. 12. 0 Air-purge function 0 0 0 = OFF ¦ 1 = ON 1. 12. 1 Antiblocking function enable 1 1 0 = OFF ¦ 1 = ON 1. 12. 2 Quiet mode activation HHP 0 0 0 = OFF ¦ 1 = ON 1. 12. 3 Quiet mode start time HHP [hh:mm] 22:00 22:00 [00:00 - 23:45][hh:mm] 1. 12. 4 Quiet mode end time HHP [hh:mm] 06:00 06:00 [00:00 - 23:45][hh:mm] 1. 12. 5 Floor drying cycle 0 0 1. 12. 6 Floor drying Flow Set Point T 55°C 55°C [25 - 60]°C 1. 12. 7 Floor drying total Remaining Days 1. 12. 9 Exogel kit activation 1 1 0 = OFF ¦ 1 = ON 1. 14 Energy Manager Statistics 1. 14. 1 Heating running hours (h/10) h/10 1. 14. 2 DHW running hours (h/10) h/10 1. 14. 3 Resistor 1 running hours (h/10) h/10 1. 14. 4 Resistor 2 running hours (h/10) h/10 1. 14. 5 Resistor 3 running hours (h/10) h/10 1. 14. 6 Cooling running hours (h/10) h/10 0 = OFF ¦ 1 = Functional Heating ¦ 2 = Curing Heating ¦ 3 = Functional Heating + Curing Heating ¦ 4 = Curing Heating + Functional Heating ¦ 5 = Manual 1. 16 EM diagnostics - 1 input 1. 16. 0 Energy Manager status 0 = Standby ¦ 1 = Antifreeze cycle ¦ 2 = Heating cycle ¦ 3 = Heating temperature reached ¦ 4 = DHW cycle ¦ 5 = Thermal cleanse function ¦ 6 = Air purge function ¦ 7 = Chimney function ¦ 8 = Floor drying cycle ¦ 9 = No heat generation ¦ 10 = Manual mode ¦ 11 = Error ¦ 12 = Initialization ¦ 13 = OFF ¦ 14 = Cool mode ¦ 15 = DHW antifreeze ¦ 16 = Photovoltaic integration ¦ 17 = Dehumidification ¦ 18 = Pump Down ¦ 19 = Defrost ¦ 20 = Buffer Heating+DHW Serving ¦ 21 = Buffer Cooling+DHW Serving ¦ 22 = Buffer Heating Serving ¦ 23 = Buffer Cooling Serving ¦ 24 = Automatic calibration 1. 16. 1 Hydraulic scheme diagnostic 0 = None ¦ 1 = Hybrid combi ¦ 2 = Hybrid system ¦ 3 = Hybrid system with thermostat ¦ 4 = Pacman plus ¦ 5 = Pacman flex ¦ 6 = Pacman flex with thermostat ¦ 7 = Pacman light plus ¦ 8 = Pacman light flex ¦ 9 = Pacman light flex with thermostat 1. 16. 2 CH flow set T °C 1. 16. 3 CH flow temperature °C 1. 16. 5 DHW storage temperature °C 1. 16. 6 Pressure switch 0 0 (visible by setting par. 1.1.7 ≠ 2) 0 = Open ¦ 1 = Close 1. 16. 7 Heating circuit pressure bar (visible with par. 1.1.7 = 2) 60 / EN
Commissioning Parameter Description Default (IDU: M) Default (IDU: L) Range - Value 1. 17 EM diagnostics - 2 input 1. 17. 0 Room Thermostat 1 0 = OFF ¦ 1 = ON 1. 17. 1 Room Thermostat 2 0 = OFF ¦ 1 = ON 1. 17. 2 AUX input 1 0 = Open ¦ 1 = Close 1. 17. 3 AUX input 2 0 = Open ¦ 1 = Close 1. 17. 4 HV input 1 0 = OFF ¦ 1 = ON 1. 17. 5 HV input 2 0 = OFF ¦ 1 = ON 1. 18 EM diagnostics - 1 output 1. 18. 0 Main circulator status 0 = OFF ¦ 1 = ON 1. 18. 1 Tank electric heater 0 = OFF ¦ 1 = ON ¦ 2 = Integration ¦ 3 = Lockout 1. 18. 2 HC Pump 2 0 = OFF ¦ 1 = ON 1. 18. 3 Diverter Valve (CH/DHW) 0 = DHW ¦ 1 = CH 1. 18. 4 Diverter Valve 2 (CH/Cooling) 0 = CH ¦ 1 = COOLING 1. 18. 5 CH backup resistance 1 0 = OFF ¦ 1 = ON 1. 18. 6 CH backup resistance 2 0 = OFF ¦ 1 = ON 1. 18. 7 CH backup resistance 3 0 = OFF ¦ 1 = ON 1. 18. 8 AUX output 1 0 = Open ¦ 1 = Close 1. 18. 9 AUX output 2 0 = Open ¦ 1 = Close 1. 19 Service 1. 19. 0 SW Version main 1. 20 System integration 1. 20. 0 PV offset DHW setpoint temperature 0°C 0°C [0 - 20]°C 1. 20. 2 Tank solar integration 0 0 0 = Absent ¦ 1 = Present 1. 20. 3 OpenTherm gateway activation 0 0 0 = OFF ¦ 1 = ON 1. 21 Error History 1. 21. 0 Last 10 errors 1. 21. 1 Reset error list 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 1. 22 Reset Menu 1. 22. 0 Reset factory settings 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 1. 23 Domestic hot water - 2 1. 23. 0 Thermal Cleanse target temp 60°C 60°C [60 - 70]°C 1. 23. 1 Antilegionella target temperature duration 1h 1h [1 - 2]h 1. 23. 2 Max Duration Antilegionella 6h 6h [4 - 12]h 1. 24 Energy meter 1. 24. 0 Energy pulse unit 0 0 0 = None ¦ 1 = kWh 1. 24. 1 Energy pulse value number 1 1 [1 - 10] 1. 24. 2 Energy pulse value factor 6 6 1. 24. 3 Energy pulse measuring type 1 1 0 = Only HP ¦ 1 = HP + Electric Heater 1. 24. 4 Backup electric heaters nominal power 2kW 2kW [1 - 3]kW 1. 24. 5 Tank electric heaters nominal power 2kW 2kW [1 - 3]kW 1. 24. 6 Backup electric heaters efficiency 95% 95% [0 - 100]% 1. 24. 7 Tank electric heaters efficiency 95% 95% [0 - 100]% 4 Zone 1 parameters 0 = /1000 ¦ 1 = /100 ¦ 2 = /10 ¦ 3 = 1 ¦ 4 = x10 ¦ 5 = x100 ¦ 6 = x1000 4. 0 Setpoint 4. 0. 0 T Day 19°C Heat - 24°C 19°C Heat - 24°C Cool Cool [10 - 30]°C 4. 0. 1 T Night 13°C Heat - 30°C 13°C Heat - 30°C Cool Cool [10 - 30]°C 4. 0. 2 T set Z1 40°C [HT] - 20°C 40°C [HT] - 20°C [LT ] [LT ] [20 - 60]°C 4. 0. 3 Zone frost temperature 5°C 5°C [2 - 15]°C 4. 1 Automatic winter mode 4. 1. 0 Automatic winter mode activation 0 0 0 = OFF ¦ 1 = ON 4. 1. 1 Automatic winter mode threshold 20°C 20°C [0 - 30]°C 4. 1. 2 Automatic winter mode delay time 300min 300min [0 - 600]min 4. 2 Settings 4. 2. 0 Zone temperature range 1 1 (0 = [LT]; 1 = [HT]) 0 = Low Temp ¦ 1 = High Temp 4. 2. 1 Thermoregulation 1 1 0 = Fix Flow T ¦ 1 = Basic Thermoreg ¦ 2 = Room T Only ¦ 3 = Outdoor T Only ¦ 4 = Room+Outdoor T 4. 2. 2 Slope 0.6 [LT] or 1.5 0.6 [LT] or 1.5 [0,2 [LT] or 0,4 [HT] - 1 [LT]or 3,5 [HT]] (visible by setting par [HT] [HT] 4.2.7 = 0) 4. 2. 3 Offset 0°C 0°C [-7 [LT] or -14 [HT] - 7 [LT] or 14[HT]]°C EN / 61
NIMBUS PLUS M NET R32 3301719 33017
Contents 1. Safety advices 1.1
a a a a a a a When connecting the c
Safety advices 1.3 Symbols affixed