Commissioning Outdoor

Commissioning Outdoor unit errors Error Description NO RESET RESET Volatile User reset HP Power Service reset OFF 1 TD sensor error - X - - 905 HP compressor mismatch error - - X - 906 HP fan mismatch error - - X - 907 HP 4-way valve mismatch error - - X - 908 Expansion valve mismatch error - - X - 909 HP zero fan speed - - X - 910 Inverter-TDM communication error X - - - 912 4-way valve error - - - X 913 LWT sensor error X - - - 914 TR sensor error X - - - 917 Freeze error - - - X 918 Pump down error - - - X 922 Freeze error - X - - 931 Inverter error X - - - 947 4-way valve error - X - - 956 HP compressor model mismatch - - X - 957 HP fan model mismatch - - X - 960 HP EWT sensor error X - - - 962 Defrost energy X - - - 968 ATGBUS TDM-EM communication error X - - - 989 Machine empty error - - - X 997 Compressor overcurrent - - X - 998 Compressor overcurrent - - - X 9E5 High-pressure pressure switch intervention X - - - 9E8 Low-pressure pressure switch error with compressor X - - - OFF 9E9 Klixon error with compressor OFF X - - - 9E18 ST1 safety thermostat error X - - - 9E21 Low refrigerant charge error - X - - 9E22 Machine empty error - - - X 9E24 EXV seized up error - X - - 9E25 EXV seized up error - - - X 9E28 High pressure protection - X - - 9E29 High pressure protection - - - X 9E31 Compressor thermostat protection - X - - 9E32 Compressor thermostat protection - - - X 9E34 Low-pressure protection - X - - 9E35 Low-pressure protection - - - X 9E36 Compressor phases current imbalance - X - - 9E37 Compressor phases current imbalance - - - X 9E38 Excessively steep compressor current variation - X - - 9E39 Excessively steep compressor current variation - - - X 32 / EN

Commissioning Inverter error Description Code (for inverter errors falling within error code 931) 35 M - 50 M - 80 M NIMBUS EXT R32 80 M-T - 120 M-T - 150 M-T 120 M - 150 M Inverter output current sensor error 1 x x x DC bus condensers pre-charge error 2 x Inverter input voltage sensor error 3 x Inverter heat sink temperature sensor error 4 x x x DSP&MCU communication error 5 x Inverter input AC overcurrent 6 x x x Inverter PFC current sensor error 7 x x Inverter PFC temperature sensor error 8 x x Corrupt EEPRPOM 9 x x PFC HW overcurrent 10 x x PFC SW overcurrent 11 x x Inverter PFC overvoltage 12 x x A/D error 13 x x Addressing error 14 x x Compressor inverse rotation 15 x x No current variation on compressor phase 16 x x Misalignment between real and calculated speed 17 x x x 33 / EN

INSTALLATION MANUALS

Views
1 year ago

Nimbus M NET R32 Range (User Manual) EU

  • Text
  • Selector
  • Horaire
  • Chauffage
  • Fonction
  • Programmation
  • Chaleur
  • Settings
  • Heating
  • Chaude
  • Permet
  • Wwwaristoncom

Commissioning Outdoor

Commissioning Outdoor unit errors Error Description NO RESET RESET Volatile User reset HP Power Service reset OFF 1 TD sensor error - X - - 905 HP compressor mismatch error - - X - 906 HP fan mismatch error - - X - 907 HP 4-way valve mismatch error - - X - 908 Expansion valve mismatch error - - X - 909 HP zero fan speed - - X - 910 Inverter-TDM communication error X - - - 912 4-way valve error - - - X 913 LWT sensor error X - - - 914 TR sensor error X - - - 917 Freeze error - - - X 918 Pump down error - - - X 922 Freeze error - X - - 931 Inverter error X - - - 947 4-way valve error - X - - 956 HP compressor model mismatch - - X - 957 HP fan model mismatch - - X - 960 HP EWT sensor error X - - - 962 Defrost energy X - - - 968 ATGBUS TDM-EM communication error X - - - 989 Machine empty error - - - X 997 Compressor overcurrent - - X - 998 Compressor overcurrent - - - X 9E5 High-pressure pressure switch intervention X - - - 9E8 Low-pressure pressure switch error with compressor X - - - OFF 9E9 Klixon error with compressor OFF X - - - 9E18 ST1 safety thermostat error X - - - 9E21 Low refrigerant charge error - X - - 9E22 Machine empty error - - - X 9E24 EXV seized up error - X - - 9E25 EXV seized up error - - - X 9E28 High pressure protection - X - - 9E29 High pressure protection - - - X 9E31 Compressor thermostat protection - X - - 9E32 Compressor thermostat protection - - - X 9E34 Low-pressure protection - X - - 9E35 Low-pressure protection - - - X 9E36 Compressor phases current imbalance - X - - 9E37 Compressor phases current imbalance - - - X 9E38 Excessively steep compressor current variation - X - - 9E39 Excessively steep compressor current variation - - - X 32 / EN

Commissioning Inverter error Description Code (for inverter errors falling within error code 931) 35 M - 50 M - 80 M NIMBUS EXT R32 80 M-T - 120 M-T - 150 M-T 120 M - 150 M Inverter output current sensor error 1 x x x DC bus condensers pre-charge error 2 x Inverter input voltage sensor error 3 x Inverter heat sink temperature sensor error 4 x x x DSP&MCU communication error 5 x Inverter input AC overcurrent 6 x x x Inverter PFC current sensor error 7 x x Inverter PFC temperature sensor error 8 x x Corrupt EEPRPOM 9 x x PFC HW overcurrent 10 x x PFC SW overcurrent 11 x x Inverter PFC overvoltage 12 x x A/D error 13 x x Addressing error 14 x x Compressor inverse rotation 15 x x No current variation on compressor phase 16 x x Misalignment between real and calculated speed 17 x x x 33 / EN