3.11.10 Time Program

3.11.10 Time Program service type set Sets the time schedule mode used by the device for heating and cooling. – "Two levels setpoint": the daily 2-level time scheduling allows for dividing the schedule into a maximum of 4 comfort slots and 4 reduced-temperature slots within the 24 hours of each day. It is possible to define a temperature set-point for the comfort slot and one for the reduced-temperature slot. – "Multilevel setpoint": in daily multi-level time scheduling, available only on specially configured products, it is possible to define up to 12 daily slots, each of which can be associated with a specific set-point temperature. 3.12 Errors and diagnostic messages 10° Error 910 HP communication error Heat Pump TDM Call the technical service Error 910 - HP communication error User Menu Fr 4-JUN 12:30 Fig. 73 Advanced settings Cooling settings Two levels setpoint AUTO function Multilevel setpoint System measurement unit Time Program mode Room temperature correction Zones selection Fig. 71 3.11.11 Room Temp Correction This parameter allows for correcting the room temperature measured by the device by ±5°C. Diagnostic events (errors, alert messages, etc.) are shown in a pop-up window in the home page. The pop-up window shows the following information: – Error code – Error description – Device/product that generated the error – Any actions to be implemented for solving the problem The pop-up window can be closed by pressing the Back button . The error notification will remain visible in the home page where the error icon , the error code and description are displayed. The window with the detailed information will automatically pop up again after one minute. It can also be opened manually by pressing the Back button again. 3.11.12 Select the zones to manage In this page you can select the hydraulic zones to be displayed in the “Zones management” menu. Select the zones to manage Zone 1 Zone 5 Zone 2 Zone 6 Zone 3 All zones Zone 4 Save Fig. 72 28 / EN

Commissioning 4. Commissioning User information Inform the user on how to operate the installed system. In particular, hand this instruction manual to the users, informing them that is must be kept near the product at all times. Inform potential users that the following actions must be carried out: – Periodically check the system water pressure. – Restore system pressure, by deaerating the system when necessary. – Adjust the setting parameters and the adjustment devices to optimise operation and reduce the system’s operating costs. – Perform regular maintenance, as envisaged in the standards. 4.12.1 Filling the system Check the water pressure on the pressure gauge regularly and make sure that the pressure is between 0.5 and 1.5 bar when the system is cold. If the pressure is below the minimum value, it must be increased through the filling cock. Close the cock once the average value of 1.2 bar has been reached. The maximum pressure of the heating/cooling system is 3 bar. a a The installation, initial start up, and configuration must be carried out in accordance with the instructions, by a qualified technician only. The manufacturer declines all responsibility for damages caused to people, animals or possessions following incorrect installation of the appliance. If frequent fillings (once a month or more frequently) are required for your system, this indicates a potential problem with the installation (leaks, expansion vessel problems). Contact your trusted installer to analyse and solve the problem quickly, and to prevent damage caused by corrosion of the components due to excessive water replacement in the system. 4.1 Initial start-up a To guarantee safety and correct operation of the system interface, it must be commissioned by a qualified technician in possession of the skills as required by law. 4.1.1 Start-up procedure – Insert the system interface on the connection slide pushing it gently downwards. After a brief initialisation, the device will be ready for being configured. – The display screen shows “Select language”. Select the desired language by rotating the selector. – Press the selector . – The display shows the “Date and Time”. Turn the selector to select day, month and year. For each selection, always press the selector to confirm. Once the date has been set, the selection shifts to the time setting. Turn the selector to set the exact time, press the selector to confirm and move to the minute selection and setting. Press the selector to confirm. – Once the date is set, the selection moves to the daylight saving time setting. Turn the selector to select AUTO or MANUAL. If you want the system to automatically update the period when daylight saving time is in use, select AUTO. – Press the selector . NOTE: The display is set by default with a multi-level set-point time schedule. If a message appears concerning the time schedule conflict: – On the home page press the “Menu” button to access the user menu. – Turn the selector to select the “Advanced settings” menu, then press the selector . – Turn the selector to select the “Type of service of the schedule programme”, then press the selector . – Turn the selector and select the same value (Two-Level Set-Point or Multi-Level Set-Point) present in the other User Interfaces (see technical parameter 0.4.3 on the boiler interface, if available) and press the selector . – If there is still a conflict, repeat the procedure and use the selector to choose the two-level set-point, then press the selector . NOTE: Some parameters are protected with an access code (safety code) which protects the appliance’s settings against unauthorised use. 29 / EN

INSTALLATION MANUALS

Views
1 year ago

Nimbus M NET R32 Range (User Manual) EU

  • Text
  • Selector
  • Horaire
  • Chauffage
  • Fonction
  • Programmation
  • Chaleur
  • Settings
  • Heating
  • Chaude
  • Permet
  • Wwwaristoncom

3.11.10 Time Program

3.11.10 Time Program service type set Sets the time schedule mode used by the device for heating and cooling. – "Two levels setpoint": the daily 2-level time scheduling allows for dividing the schedule into a maximum of 4 comfort slots and 4 reduced-temperature slots within the 24 hours of each day. It is possible to define a temperature set-point for the comfort slot and one for the reduced-temperature slot. – "Multilevel setpoint": in daily multi-level time scheduling, available only on specially configured products, it is possible to define up to 12 daily slots, each of which can be associated with a specific set-point temperature. 3.12 Errors and diagnostic messages 10° Error 910 HP communication error Heat Pump TDM Call the technical service Error 910 - HP communication error User Menu Fr 4-JUN 12:30 Fig. 73 Advanced settings Cooling settings Two levels setpoint AUTO function Multilevel setpoint System measurement unit Time Program mode Room temperature correction Zones selection Fig. 71 3.11.11 Room Temp Correction This parameter allows for correcting the room temperature measured by the device by ±5°C. Diagnostic events (errors, alert messages, etc.) are shown in a pop-up window in the home page. The pop-up window shows the following information: – Error code – Error description – Device/product that generated the error – Any actions to be implemented for solving the problem The pop-up window can be closed by pressing the Back button . The error notification will remain visible in the home page where the error icon , the error code and description are displayed. The window with the detailed information will automatically pop up again after one minute. It can also be opened manually by pressing the Back button again. 3.11.12 Select the zones to manage In this page you can select the hydraulic zones to be displayed in the “Zones management” menu. Select the zones to manage Zone 1 Zone 5 Zone 2 Zone 6 Zone 3 All zones Zone 4 Save Fig. 72 28 / EN

Commissioning 4. Commissioning User information Inform the user on how to operate the installed system. In particular, hand this instruction manual to the users, informing them that is must be kept near the product at all times. Inform potential users that the following actions must be carried out: – Periodically check the system water pressure. – Restore system pressure, by deaerating the system when necessary. – Adjust the setting parameters and the adjustment devices to optimise operation and reduce the system’s operating costs. – Perform regular maintenance, as envisaged in the standards. 4.12.1 Filling the system Check the water pressure on the pressure gauge regularly and make sure that the pressure is between 0.5 and 1.5 bar when the system is cold. If the pressure is below the minimum value, it must be increased through the filling cock. Close the cock once the average value of 1.2 bar has been reached. The maximum pressure of the heating/cooling system is 3 bar. a a The installation, initial start up, and configuration must be carried out in accordance with the instructions, by a qualified technician only. The manufacturer declines all responsibility for damages caused to people, animals or possessions following incorrect installation of the appliance. If frequent fillings (once a month or more frequently) are required for your system, this indicates a potential problem with the installation (leaks, expansion vessel problems). Contact your trusted installer to analyse and solve the problem quickly, and to prevent damage caused by corrosion of the components due to excessive water replacement in the system. 4.1 Initial start-up a To guarantee safety and correct operation of the system interface, it must be commissioned by a qualified technician in possession of the skills as required by law. 4.1.1 Start-up procedure – Insert the system interface on the connection slide pushing it gently downwards. After a brief initialisation, the device will be ready for being configured. – The display screen shows “Select language”. Select the desired language by rotating the selector. – Press the selector . – The display shows the “Date and Time”. Turn the selector to select day, month and year. For each selection, always press the selector to confirm. Once the date has been set, the selection shifts to the time setting. Turn the selector to set the exact time, press the selector to confirm and move to the minute selection and setting. Press the selector to confirm. – Once the date is set, the selection moves to the daylight saving time setting. Turn the selector to select AUTO or MANUAL. If you want the system to automatically update the period when daylight saving time is in use, select AUTO. – Press the selector . NOTE: The display is set by default with a multi-level set-point time schedule. If a message appears concerning the time schedule conflict: – On the home page press the “Menu” button to access the user menu. – Turn the selector to select the “Advanced settings” menu, then press the selector . – Turn the selector to select the “Type of service of the schedule programme”, then press the selector . – Turn the selector and select the same value (Two-Level Set-Point or Multi-Level Set-Point) present in the other User Interfaces (see technical parameter 0.4.3 on the boiler interface, if available) and press the selector . – If there is still a conflict, repeat the procedure and use the selector to choose the two-level set-point, then press the selector . NOTE: Some parameters are protected with an access code (safety code) which protects the appliance’s settings against unauthorised use. 29 / EN