Commissioning Parameter Description Default Default (IDU: M) (IDU: L) Range - Value 7. 2. 4 Valves overrun time s s s 7. 2. 5 Valves Driving Delta T s s s 7. 2. 6 Valves Kp Heating 7. 2. 7 Mixing zones shifting mode 0 0 0 = Disabled ¦ 1 = Enabled 7. 2. 8 Pumps overrun time 150s 150s [150 - 600]s 7. 2. 9 HC pump overrun DHW 0 0 0 = OFF ¦ 1 = ON 7. 3 Cooling 7. 3. 0 FlowT Offset Cooling 1°C 1°C [0 - 6]°C 7. 3. 1 Cooling mode activation 0 0 [0 - 1] 7. 3. 3 Valves Kp Cooling 7. 8 Error History 7. 8. 0 Last 10 errors 7. 8. 1 Reset error list 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 7. 9 Reset Menu 7. 9. 0 Reset factory settings 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 13 Heat Pump TDM 13. 1 Input configuration 13. 1. 0 TDM Flow Sensor Type 0 = Not Selected (Self-Recognition) ¦ 1 = DN 15 ¦ 2 = DN 20 13. 2 Output configuration 13. 2. 1 HP Electric Heater Config 0 = OFF ¦ 1 = ON 13. 4 Water circulation 13. 4. 4 Delta T pump setpoint °C 13. 4. 5 Max PWM Pump % 13. 4. 6 Min PWM Pump % 13. 5 Manual Mode - 1 13. 5. 1 Compressor frequency setting 13. 5. 2 Fan 1 rpm setting 13. 5. 3 Fan 2 rpm setting 13. 6 Test & Utilities 13. 6. 0 Refrigerant Recover 0 = OFF ¦ 1 = ON 13. 6. 1 Defrost 0 = OFF ¦ 1 = ON 13. 7 Statistics 13. 7. 0 HP running hours (h/10) h/10 13. 7. 1 HP on cycles (n/10) n/10 13. 7. 2 HP defrost hours (h/10) h/10 13. 8 HP diagnostics - input 1 13. 8. 0 Outside air temperature °C 13. 8. 1 HP water flow temp °C 13. 8. 2 HP water return temp °C 13. 8. 3 HP Evaporator temp °C 13. 8. 4 HP Suction temp °C 13. 8. 5 HP Discharge temp °C 13. 8. 6 HP condenser outlet temp °C 13. 8. 7 TEO °C 13. 9 HP diagnostics - input 2 13. 9. 0 Heat pump mode 0 = OFF ¦ 1 = Standby ¦ 2 = Cooling ¦ 3 = Heating ¦ 4 = Booster Heating ¦ 5 = Booster Cooling ¦ 6 = Rating Heating Mode ¦ 7 = Rating Cooling Mode ¦ 8 = Freeze Protection ¦ 9 = Defrost ¦ 10 = High temperature protection ¦ 11 = Timeguard ¦ 12 = System Fail ¦ 13 = Hard System Fail ¦ 14 = Pump Down ¦ 15 = Soft Fail Mode ¦ 16 = Rating only fan ¦ 17 = Defrost ¦ 18 = Cascade Heating ¦ 19 = Cascade cooling 13. 9. 1 Last inverter error 13. 9. 2 Safety thermostat 0 = Open ¦ 1 = Close 13. 9. 3 Flowmeter l/min 13. 9. 4 Flow Switch 0 = Open ¦ 1 = Close 13. 9. 5 Inverter shut off protection 13. 9. 6 Evaporator pressure P bar 13. 9. 7 Condenser pressure P bar 13. 10 HP diagnostics - output 1 13. 10. 0 Inverter Capacity kW 13. 10. 1 HP actual compressor frequency Hz 13. 10. 2 HP set compressor modulation % 68 / EN
Commissioning Parameter Description Default (IDU: M) Default (IDU: L) Range - Value 13. 10. 3 Electric Heater 1 0 = OFF ¦ 1 = ON 13. 10. 5 Measured rpm fan 1 Rpm 13. 10. 6 Measured rpm fan 2 Rpm 13. 10. 7 Expansion valve 13. 10. 8 Expansion valve 2 13. 11 HP diagnostics - output 2 13. 11. 0 Compressor on/off 0 = OFF ¦ 1 = ON 13. 11. 1 Compressor preheating 0 = OFF ¦ 1 = ON 13. 11. 2 Current fan 1 status 0 = OFF ¦ 1 = ON 13. 11. 3 Current fan 2 status 0 = OFF ¦ 1 = ON 13. 11. 4 4way valve heat / cool 0 = Heating ¦ 1 = Cooling 13. 11. 5 Base panel heater status 0 = OFF ¦ 1 = ON 13. 12 Service 13. 12. 0 SW Version main 13. 13 Error History 13. 13. 0 Last 10 errors 13. 13. 1 Reset error list 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 13. 14 Reset Menu 13. 14. 0 Reset factory settings 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 13. 14. 1 Service reset 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 13. 14. 2 Cmp timer reset 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 20 Buffer 20. 0 Configuration 20. 0. 0 Buffer activation 0 0 0 = OFF ¦ 1 = ON 20. 0. 1 Buffer charge mode 1 1 1 = Partial charge ¦ 2 = Full charge 20. 0. 2 Buffer setpoint temperature hysteresis 5°C 5°C [0 - 20]°C 20. 0. 3 Buffer comfort setpoint heating 40°C 40°C [20 - 70]°C 20. 0. 4 Buffer comfort setpoint cooling 18°C 18°C [5 - 23]°C (always visible by setting par 1.8.0 = 1) 20. 0. 5 SG Ready Buffer setpoint 40°C 40°C [20 - 70]°C (visible with par. 20.0.0 = 1) 20. 0. 6 Offset PV integration setpoint 0°C 0°C [0 - 20]°C (visible with par. 20.0.0 = 1) 20. 0. 7 Buffer setpoint mode 0 0 0 = Fixed ¦ 1 = Variable 20. 0. 8 Buffer hysteresis cooling 5°C 5°C [0 - 20]°C (visible with par. 20.0.0 = 1 and par 1.8.0 = 1) 20. 1 Diagnostics 20. 1. 0 Low sensor temperature °C 20. 1. 2 High sensor temperature °C 20. 1. 3 Buffer charge request (visible with par. 20.0.0 = 1) 0 = OFF ¦ 1 = ON 20. 1. 4 Buffer status 0 = Absent ¦ 1 = Disabled ¦ 2 = OFF ¦ 3 = Charged ¦ 4 = Charge request ¦ 5 = Antifreeze cycle ¦ 6 = Antifrost ¦ 7 = Buffer high probe error ¦ 8 = Buffer overtemperature ¦ 9 = Electric charge request ¦ 10 = Photovoltaic charge request 20. 2 Statistics 20. 2. 2 Buffer charge hours Heating (/10) h 20. 2. 3 Buffer charge hours Cooling (/10) h 20. 3 Time program 20. 3. 0 Control mode 2 2 0 = Disabled ¦ 1 = Time Based ¦ 2 = Always active 20. 3. 1 Reduced Setpoint heating 35°C 35°C [20 - 40]°C 20. 3. 2 Reduced Setpoint cooling 23°C 23°C [18 - 23]°C (always visible by setting par 1.8.0 = 1) 20. 4 System settings 20. 4. 0 Buffer integration scheme 0 0 0 = Series ¦ 1 = Parallel 20. 4. 1 Buffer solar integration 0 0 0 = NO ¦ 1 = YES 20. 4. 2 Buffer offset compensation heating 0°C 0°C [0 - 20]°C 20. 4. 3 Buffer offset compensation cooling 0°C 0°C [0 - 20]°C (visible by setting par 1.8.0 = 1) 20. 4. 4 Buffer electric integration offset 0°C 0°C [0 - 20]°C 20. 4. 5 CH switch off offset 0°C 0°C [0 - 0]°C 20. 4. 6 Cooling switch off offset 0°C 0°C [0 - 0]°C (visible by setting par 1.8.0 = 1) EN / 69
NIMBUS COMPACT UK M NET R32 3302561
Contents 1. Safety advices 1.1
a a a a a a a When connecting the c
Safety advices 1.3 Symbols affixed
Description of the system 2.1.2 Dim
Description of the system 2.2 Indoo
Description of the system 2.2.2 Dim
Description of the system 2.4 Ident
Loading...
Loading...
Commissioning Parameter Description Default Default (IDU: M) (IDU: L) Range - Value 7. 2. 4 Valves overrun time s s s 7. 2. 5 Valves Driving Delta T s s s 7. 2. 6 Valves Kp Heating 7. 2. 7 Mixing zones shifting mode 0 0 0 = Disabled ¦ 1 = Enabled 7. 2. 8 Pumps overrun time 150s 150s [150 - 600]s 7. 2. 9 HC pump overrun DHW 0 0 0 = OFF ¦ 1 = ON 7. 3 Cooling 7. 3. 0 FlowT Offset Cooling 1°C 1°C [0 - 6]°C 7. 3. 1 Cooling mode activation 0 0 [0 - 1] 7. 3. 3 Valves Kp Cooling 7. 8 Error History 7. 8. 0 Last 10 errors 7. 8. 1 Reset error list 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 7. 9 Reset Menu 7. 9. 0 Reset factory settings 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 13 Heat Pump TDM 13. 1 Input configuration 13. 1. 0 TDM Flow Sensor Type 0 = Not Selected (Self-Recognition) ¦ 1 = DN 15 ¦ 2 = DN 20 13. 2 Output configuration 13. 2. 1 HP Electric Heater Config 0 = OFF ¦ 1 = ON 13. 4 Water circulation 13. 4. 4 Delta T pump setpoint °C 13. 4. 5 Max PWM Pump % 13. 4. 6 Min PWM Pump % 13. 5 Manual Mode - 1 13. 5. 1 Compressor frequency setting 13. 5. 2 Fan 1 rpm setting 13. 5. 3 Fan 2 rpm setting 13. 6 Test & Utilities 13. 6. 0 Refrigerant Recover 0 = OFF ¦ 1 = ON 13. 6. 1 Defrost 0 = OFF ¦ 1 = ON 13. 7 Statistics 13. 7. 0 HP running hours (h/10) h/10 13. 7. 1 HP on cycles (n/10) n/10 13. 7. 2 HP defrost hours (h/10) h/10 13. 8 HP diagnostics - input 1 13. 8. 0 Outside air temperature °C 13. 8. 1 HP water flow temp °C 13. 8. 2 HP water return temp °C 13. 8. 3 HP Evaporator temp °C 13. 8. 4 HP Suction temp °C 13. 8. 5 HP Discharge temp °C 13. 8. 6 HP condenser outlet temp °C 13. 8. 7 TEO °C 13. 9 HP diagnostics - input 2 13. 9. 0 Heat pump mode 0 = OFF ¦ 1 = Standby ¦ 2 = Cooling ¦ 3 = Heating ¦ 4 = Booster Heating ¦ 5 = Booster Cooling ¦ 6 = Rating Heating Mode ¦ 7 = Rating Cooling Mode ¦ 8 = Freeze Protection ¦ 9 = Defrost ¦ 10 = High temperature protection ¦ 11 = Timeguard ¦ 12 = System Fail ¦ 13 = Hard System Fail ¦ 14 = Pump Down ¦ 15 = Soft Fail Mode ¦ 16 = Rating only fan ¦ 17 = Defrost ¦ 18 = Cascade Heating ¦ 19 = Cascade cooling 13. 9. 1 Last inverter error 13. 9. 2 Safety thermostat 0 = Open ¦ 1 = Close 13. 9. 3 Flowmeter l/min 13. 9. 4 Flow Switch 0 = Open ¦ 1 = Close 13. 9. 5 Inverter shut off protection 13. 9. 6 Evaporator pressure P bar 13. 9. 7 Condenser pressure P bar 13. 10 HP diagnostics - output 1 13. 10. 0 Inverter Capacity kW 13. 10. 1 HP actual compressor frequency Hz 13. 10. 2 HP set compressor modulation % 68 / EN
Commissioning Parameter Description Default (IDU: M) Default (IDU: L) Range - Value 13. 10. 3 Electric Heater 1 0 = OFF ¦ 1 = ON 13. 10. 5 Measured rpm fan 1 Rpm 13. 10. 6 Measured rpm fan 2 Rpm 13. 10. 7 Expansion valve 13. 10. 8 Expansion valve 2 13. 11 HP diagnostics - output 2 13. 11. 0 Compressor on/off 0 = OFF ¦ 1 = ON 13. 11. 1 Compressor preheating 0 = OFF ¦ 1 = ON 13. 11. 2 Current fan 1 status 0 = OFF ¦ 1 = ON 13. 11. 3 Current fan 2 status 0 = OFF ¦ 1 = ON 13. 11. 4 4way valve heat / cool 0 = Heating ¦ 1 = Cooling 13. 11. 5 Base panel heater status 0 = OFF ¦ 1 = ON 13. 12 Service 13. 12. 0 SW Version main 13. 13 Error History 13. 13. 0 Last 10 errors 13. 13. 1 Reset error list 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 13. 14 Reset Menu 13. 14. 0 Reset factory settings 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 13. 14. 1 Service reset 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 13. 14. 2 Cmp timer reset 0 = Do you really want to perform the reset ? If you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. 20 Buffer 20. 0 Configuration 20. 0. 0 Buffer activation 0 0 0 = OFF ¦ 1 = ON 20. 0. 1 Buffer charge mode 1 1 1 = Partial charge ¦ 2 = Full charge 20. 0. 2 Buffer setpoint temperature hysteresis 5°C 5°C [0 - 20]°C 20. 0. 3 Buffer comfort setpoint heating 40°C 40°C [20 - 70]°C 20. 0. 4 Buffer comfort setpoint cooling 18°C 18°C [5 - 23]°C (always visible by setting par 1.8.0 = 1) 20. 0. 5 SG Ready Buffer setpoint 40°C 40°C [20 - 70]°C (visible with par. 20.0.0 = 1) 20. 0. 6 Offset PV integration setpoint 0°C 0°C [0 - 20]°C (visible with par. 20.0.0 = 1) 20. 0. 7 Buffer setpoint mode 0 0 0 = Fixed ¦ 1 = Variable 20. 0. 8 Buffer hysteresis cooling 5°C 5°C [0 - 20]°C (visible with par. 20.0.0 = 1 and par 1.8.0 = 1) 20. 1 Diagnostics 20. 1. 0 Low sensor temperature °C 20. 1. 2 High sensor temperature °C 20. 1. 3 Buffer charge request (visible with par. 20.0.0 = 1) 0 = OFF ¦ 1 = ON 20. 1. 4 Buffer status 0 = Absent ¦ 1 = Disabled ¦ 2 = OFF ¦ 3 = Charged ¦ 4 = Charge request ¦ 5 = Antifreeze cycle ¦ 6 = Antifrost ¦ 7 = Buffer high probe error ¦ 8 = Buffer overtemperature ¦ 9 = Electric charge request ¦ 10 = Photovoltaic charge request 20. 2 Statistics 20. 2. 2 Buffer charge hours Heating (/10) h 20. 2. 3 Buffer charge hours Cooling (/10) h 20. 3 Time program 20. 3. 0 Control mode 2 2 0 = Disabled ¦ 1 = Time Based ¦ 2 = Always active 20. 3. 1 Reduced Setpoint heating 35°C 35°C [20 - 40]°C 20. 3. 2 Reduced Setpoint cooling 23°C 23°C [18 - 23]°C (always visible by setting par 1.8.0 = 1) 20. 4 System settings 20. 4. 0 Buffer integration scheme 0 0 0 = Series ¦ 1 = Parallel 20. 4. 1 Buffer solar integration 0 0 0 = NO ¦ 1 = YES 20. 4. 2 Buffer offset compensation heating 0°C 0°C [0 - 20]°C 20. 4. 3 Buffer offset compensation cooling 0°C 0°C [0 - 20]°C (visible by setting par 1.8.0 = 1) 20. 4. 4 Buffer electric integration offset 0°C 0°C [0 - 20]°C 20. 4. 5 CH switch off offset 0°C 0°C [0 - 0]°C 20. 4. 6 Cooling switch off offset 0°C 0°C [0 - 0]°C (visible by setting par 1.8.0 = 1) EN / 69
NIMBUS COMPACT UK M NET R32 3302561
Contents 1. Safety advices 1.1
a a a a a a a When connecting the c
Safety advices 1.3 Symbols affixed
Description of the system 2.1.2 Dim
Description of the system 2.2 Indoo
Description of the system 2.2.2 Dim
Description of the system 2.4 Ident