Commissioning Parameter Description Default Default (IDU: M) (IDU: L) Range - Value 4. 2. 7 Thermoregulation logic 0 0 0 = Classic ¦ 1 = Smart 4. 2. 8 Quick night setback 0 0 0 = OFF ¦ 1 = ON 4. 2. 9 Heat request mode 0 0 0 = Standard ¦ 1 = RT Time Programs Exclusion ¦ 2 = Forcing Heat Demand 4. 3 Diagnostics 4. 3. 0 Room T °C 4. 3. 1 Room T setpoint °C 4. 3. 2 Flow temperature °C (Visible only with Zone Module) 4. 3. 3 Return temperature °C (Visible only with Zone Module) 4. 3. 4 Heat Request Z1 0 = OFF ¦ 1 = ON 4. 3. 5 Pump status (Visible only with Zone Module) 0 = OFF ¦ 1 = ON 4. 3. 7 Relative humidity % 4. 3. 8 Zone flow temperature setpoint °C 4. 4 Zone module settings (Visible only with Zone Module) 4. 4. 0 Zone pump modulation 1 1 0 = Fixed ¦ 1 = Modulating on DeltaT ¦ 2 = Modulating on pressure 4. 4. 1 Target deltaT for pump modulation 20°C [HT] or 7°C 20°C [HT] or 7°C [LT ] [LT ] [4 - 25]°C 4. 4. 2 Pump fixed speed 1 1 [0.2 - 1]% 4. 5 Cooling (always visible by setting par 1.8.0 = 1) 4. 5. 0 T Set Cool 7°C[FC] or 7°C[FC] or 18°C[UFH] 18°C[UFH] [par 4.5.7 - par 4.5.6]°C 4. 5. 1 Cooling Temp Range 0 0 (0 = [FC]; 1 = [UFH]) 0 = Fan Coil ¦ 1 = Underfloor 4. 5. 2 Thermoregulation 0 0 0 = ON/OFF Thermostat ¦ 1 = Fix Flow T ¦ 2 = Outdoor T Only 4. 5. 3 Slope 25 [FC] or 20 25 [FC] or 20 [UFH] [UFH] [18 [FC] or 0 [UFH] - 33 [FC] or 60 [UFH]] 4. 5. 4 Offset 0°C 0°C [-2,5 - 2,5]°C 4. 5. 6 Max T 12°C [FC] 23°C 12°C [FC] 23°C [UFH] [UFH] [7 [FC] or 18 [UFH] - 15 [FC] or 23°[UFH]]°C 4. 5. 7 Min T 7°C [FC] 18°C 7°C [FC] 18°C [UFH] [UFH] [7 [FC] or 15 [UFH] - 12 [FC] or 23 [UFH]]°C 4. 5. 8 Target deltaT for pump modulation 5°C 5°C [4 - 20]°C (Visible only with Zone Module) 4. 7 Zone regulation parameters (visible by setting par 4.2.7 or 5.2.7 = 1) 4. 7. 0 Heating Type 0 0 (visible by setting par 4.2.7 = 1) 0 = Floor Heating ¦ 1 = Radiators ¦ 2 = Floor Heating (main) + Radiators ¦ 3 = Radiators (main) + Floor Heating ¦ 4 = Convection ¦ 5 = Air Heating 4. 7. 1 Room Influence 0 0 (visible by setting par 4.2.7 = 1) 0 = OFF ¦ 1 = Less ¦ 2 = Medium ¦ 3 = More 4. 7. 2 Building Isolation Level 0 0 (visible by setting par 4.2.7 = 1) 0 = Poor ¦ 1 = Average ¦ 2 = Good 4. 7. 3 Building Size 0 0 (visible by setting par 4.2.7 = 1) 0 = Small ¦ 1 = Average ¦ 2 = Large 4. 7. 4 Climatic Zone 0°C 0°C [-20 - 30]°C (visible by setting par 4.2.7 = 1) 4. 7. 5 Auto Slope Adaptation 0 0 (visible by setting par 4.2.7 or 5.2.7 = 1) 0 = OFF ¦ 1 = ON 4. 8 Advanced settings 4. 8. 3 Heating controller 2 2 0 = None ¦ 1 = Room thermostat ¦ 2 = Room Sensor 4. 8. 4 Cooling controller 1 1 (always visible by setting par 1.8.0 = 1) 0 = None ¦ 1 = Room thermostat ¦ 2 = Room Sensor 4. 8. 7 Humidity Control Threshold 70% 70% [40 - 100]% (visible by setting par 1.8.0 = 1) 4. 8. 8 Humidity Control Hysteresis 10% 10% [0 - 30]% (visible by setting par 1.8.0 = 1) 4. 8. 9 Humidity Alarm 0 0 (visible by setting par 1.8.0 = 1) 0 = None ¦ 1 = Stop 5 Zone 2 parameters 5. 0 Setpoint 5. 0. 0 T Day 19°C Heat - 24°C 19°C Heat - 24°C Cool Cool [10 - 30]°C 5. 0. 1 T Night 13°C Heat - 30°C 13°C Heat - 30°C Cool Cool [10 - 30]°C 5. 0. 2 T set Z2 40°C [HT] - 20°C 40°C [HT] - 20°C [LT ] [LT ] [20 - 45]°C 5. 0. 3 Zone frost temperature 5°C 5°C [2 - 15]°C 5. 1 Automatic winter mode 5. 1. 0 Automatic winter mode activation 0 0 0 = OFF ¦ 1 = ON 5. 1. 1 Automatic winter mode threshold 20°C 20°C [0 - 30]°C 5. 1. 2 Automatic winter mode delay time 300min 300min [0 - 600]min 5. 2 Settings 5. 2. 0 Zone temperature range 0 0 (0 = [LT]; 1 = [HT]) 0 = Low Temp ¦ 1 = High Temp 5. 2. 1 Thermoregulation 1 1 0 = Fix Flow T ¦ 1 = Basic Thermoreg ¦ 2 = Room T Only ¦ 3 = Outdoor T Only ¦ 4 = Room+Outdoor T 5. 2. 2 Slope 0.6 [LT] or 1.5 0.6 [LT] or 1.5 [0,2 [LT] or 0,4 [HT] - 1 [LT]or 3,5 [HT]] (visible by setting par [HT] [HT] 4.2.7 = 0) 66 / EN
Commissioning Parameter Description Default Default (IDU: M) (IDU: L) Range - Value 5. 2. 3 Offset 0°C 0°C [-7 [LT] or -14 [HT] - 7 [LT] or 14 [HT]]°C 5. 2. 4 Room Influence Proportional 2 [LT] or 10 [HT] 2 [LT] or 10 [HT] [0 - 20] (visible by setting par 4.2.7 = 0) 5. 2. 5 Max T 60°C [HT] or 45°C 60°C [HT] or 45°C [LT ] [LT ] [20 - 70 [HT] or 45 [LT]]°C 5. 2. 6 Min T 20°C[HT] or 20°C[HT] or 20°C[LT] 20°C[LT] [20 - 60 [HT] or 45 [LT]]°C 5. 2. 7 Thermoregulation logic 0 0 0 = Classic ¦ 1 = Smart 5. 2. 8 Quick night setback 0 0 0 = OFF ¦ 1 = ON 5. 2. 9 Heat request mode 0 0 0 = Standard ¦ 1 = RT Time Programs Exclusion ¦ 2 = Forcing Heat Demand 5. 3 Diagnostics 5. 3. 0 Room T °C 5. 3. 1 Room T setpoint °C 5. 3. 2 Flow temperature °C (Visible only with Zone Module) 5. 3. 3 Return temperature °C (Visible only with Zone Module) 5. 3. 4 Heat Request Z2 0 = OFF ¦ 1 = ON 5. 3. 5 Pump status (Visible only with Zone Module) 0 = OFF ¦ 1 = ON 5. 3. 7 Relative humidity % 5. 3. 8 Zone flow temperature setpoint °C 5. 4 Zone module settings (Visible only with Zone Module) 5. 4. 0 Zone pump modulation 0 = Fixed ¦ 1 = Modulating on DeltaT ¦ 2 = Modulating on pressure 5. 4. 1 Target deltaT for pump modulation 20°C [HT] or 7°C 20°C [HT] or 7°C [LT ] [LT ] [4 - 25]°C 5. 4. 2 Pump fixed speed 1 1 [0.2 - 1]% 5. 5 Cooling (always visible by setting par 1.8.0 = 1) 5. 5. 0 T Set Cool 7°C[FC] or 7°C[FC] or 18°C[UFH] 18°C[UFH] [par 5.5.7 - par 5.5.6]°C 5. 5. 1 Cooling Temp Range 1 1 (0 = [FC]; 1 = [UFH]) 0 = Fan Coil ¦ 1 = Underfloor 5. 5. 2 Thermoregulation 0 0 0 = ON/OFF Thermostat ¦ 1 = Fix Flow T ¦ 2 = Outdoor T Only 5. 5. 3 Slope 25 [FC] or 20 25 [FC] or 20 [UFH] [UFH] [18 [FC] or 0 [UFH] - 33 [FC] or 60 [UFH]] 5. 5. 4 Offset 0°C 0°C [-2,5 - 2,5]°C 5. 5. 6 Max T 12°C [FC] 23°C 12°C [FC] 23°C [UFH] [UFH] [7 [FC] or 18 [UFH] - 15 [FC] or 23°[UFH]]°C 5. 5. 7 Min T 7°C [FC] 18°C 7°C [FC] 18°C [UFH] [UFH] [7 [FC] or 15 [UFH] - 12 [FC] or 23 [UFH]]°C 5. 5. 8 Target deltaT for pump modulation 5°C 5°C [4 - 20]°C (Visible only with Zone Module) 5. 7 Zone regulation parameters (visible by setting par 4.2.7 or 5.2.7 = 1) 5. 7. 0 Heating Type 0 0 (visible by setting par 4.2.7 = 1) 0 = Floor Heating ¦ 1 = Radiators ¦ 2 = Floor Heating (main) + Radiators ¦ 3 = Radiators (main) + Floor Heating ¦ 4 = Convection ¦ 5 = Air Heating 5. 7. 1 Room Influence 0 0 (visible by setting par 4.2.7 = 1) 0 = OFF ¦ 1 = Less ¦ 2 = Medium ¦ 3 = More 5. 7. 2 Building Isolation Level 0 0 (visible by setting par 4.2.7 = 1) 0 = Poor ¦ 1 = Average ¦ 2 = Good 5. 7. 3 Building Size 0 0 (visible by setting par 4.2.7 = 1) 0 = Small ¦ 1 = Average ¦ 2 = Large 5. 7. 4 Climatic Zone 0°C 0°C [-20 - 30]°C (visible by setting par 4.2.7 = 1) 5. 7. 5 Auto Slope Adaptation 0 0 (visible by setting par 4.2.7 or 5.2.7 = 1) 0 = OFF ¦ 1 = ON 5. 8 Advanced settings 5. 8. 3 Heating controller 2 2 0 = None ¦ 1 = Room thermostat ¦ 2 = Room Sensor 5. 8. 4 Cooling controller 1 1 (always visible by setting par 1.8.0 = 1) 0 = None ¦ 1 = Room thermostat ¦ 2 = Room Sensor 5. 8. 7 Humidity Control Threshold 70% 70% [40 - 100]% (visible by setting par 1.8.0 = 1) 5. 8. 8 Humidity Control Hysteresis 10% 10% [0 - 30]% (visible by setting par 1.8.0 = 1) 5. 8. 9 Humidity Alarm 0 0 (visible by setting par 1.8.0 = 1) 0 = None ¦ 1 = Stop 7 Zone Module (Visible only with Zone Module) 7. 1 Manual mode (Visible only with Zone Module) 7. 1. 0 Manual mode activation 0 0 0 = OFF ¦ 1 = ON 7. 1. 1 Z1 Pump control 0 0 0 = OFF ¦ 1 = ON 7. 1. 2 Z2 Pump control 0 0 0 = OFF ¦ 1 = ON 7. 1. 3 Z3 Pump control 0 0 0 = OFF ¦ 1 = ON 7. 1. 4 Z2 Mix Valve Control 0 0 0 = OFF ¦ 1 = Open ¦ 2 = Close 7. 1. 5 Z3 Mix Valve Control 0 0 0 = OFF ¦ 1 = Open ¦ 2 = Close 7. 1. 6 Z1 Mix Valve Control 0 0 0 = OFF ¦ 1 = Open ¦ 2 = Close 7. 2 General Zone Module 7. 2. 0 Hydraulic scheme 0 0 0 = Not defined ¦ 1 = MCD ¦ 2 = MGM II ¦ 3 = MGM III ¦ 4 = MGZ I ¦ 5 = MGZ II ¦ 6 = MGZ III 7. 2. 1 FlowT Offset 1°C 1°C [0 - 40]°C 7. 2. 2 Auxiliary output setting 0 0 0 = Heat request ¦ 1 = External pump ¦ 2 = Alarm 7. 2. 3 External temperature correction 0°C 0°C [-3 - 3]°C EN / 67
NIMBUS COMPACT UK M NET R32 3302561
Contents 1. Safety advices 1.1
a a a a a a a When connecting the c
Safety advices 1.3 Symbols affixed
Description of the system 2.1.2 Dim
Description of the system 2.2 Indoo
Description of the system 2.2.2 Dim
Loading...
Loading...
Commissioning Parameter Description Default Default (IDU: M) (IDU: L) Range - Value 4. 2. 7 Thermoregulation logic 0 0 0 = Classic ¦ 1 = Smart 4. 2. 8 Quick night setback 0 0 0 = OFF ¦ 1 = ON 4. 2. 9 Heat request mode 0 0 0 = Standard ¦ 1 = RT Time Programs Exclusion ¦ 2 = Forcing Heat Demand 4. 3 Diagnostics 4. 3. 0 Room T °C 4. 3. 1 Room T setpoint °C 4. 3. 2 Flow temperature °C (Visible only with Zone Module) 4. 3. 3 Return temperature °C (Visible only with Zone Module) 4. 3. 4 Heat Request Z1 0 = OFF ¦ 1 = ON 4. 3. 5 Pump status (Visible only with Zone Module) 0 = OFF ¦ 1 = ON 4. 3. 7 Relative humidity % 4. 3. 8 Zone flow temperature setpoint °C 4. 4 Zone module settings (Visible only with Zone Module) 4. 4. 0 Zone pump modulation 1 1 0 = Fixed ¦ 1 = Modulating on DeltaT ¦ 2 = Modulating on pressure 4. 4. 1 Target deltaT for pump modulation 20°C [HT] or 7°C 20°C [HT] or 7°C [LT ] [LT ] [4 - 25]°C 4. 4. 2 Pump fixed speed 1 1 [0.2 - 1]% 4. 5 Cooling (always visible by setting par 1.8.0 = 1) 4. 5. 0 T Set Cool 7°C[FC] or 7°C[FC] or 18°C[UFH] 18°C[UFH] [par 4.5.7 - par 4.5.6]°C 4. 5. 1 Cooling Temp Range 0 0 (0 = [FC]; 1 = [UFH]) 0 = Fan Coil ¦ 1 = Underfloor 4. 5. 2 Thermoregulation 0 0 0 = ON/OFF Thermostat ¦ 1 = Fix Flow T ¦ 2 = Outdoor T Only 4. 5. 3 Slope 25 [FC] or 20 25 [FC] or 20 [UFH] [UFH] [18 [FC] or 0 [UFH] - 33 [FC] or 60 [UFH]] 4. 5. 4 Offset 0°C 0°C [-2,5 - 2,5]°C 4. 5. 6 Max T 12°C [FC] 23°C 12°C [FC] 23°C [UFH] [UFH] [7 [FC] or 18 [UFH] - 15 [FC] or 23°[UFH]]°C 4. 5. 7 Min T 7°C [FC] 18°C 7°C [FC] 18°C [UFH] [UFH] [7 [FC] or 15 [UFH] - 12 [FC] or 23 [UFH]]°C 4. 5. 8 Target deltaT for pump modulation 5°C 5°C [4 - 20]°C (Visible only with Zone Module) 4. 7 Zone regulation parameters (visible by setting par 4.2.7 or 5.2.7 = 1) 4. 7. 0 Heating Type 0 0 (visible by setting par 4.2.7 = 1) 0 = Floor Heating ¦ 1 = Radiators ¦ 2 = Floor Heating (main) + Radiators ¦ 3 = Radiators (main) + Floor Heating ¦ 4 = Convection ¦ 5 = Air Heating 4. 7. 1 Room Influence 0 0 (visible by setting par 4.2.7 = 1) 0 = OFF ¦ 1 = Less ¦ 2 = Medium ¦ 3 = More 4. 7. 2 Building Isolation Level 0 0 (visible by setting par 4.2.7 = 1) 0 = Poor ¦ 1 = Average ¦ 2 = Good 4. 7. 3 Building Size 0 0 (visible by setting par 4.2.7 = 1) 0 = Small ¦ 1 = Average ¦ 2 = Large 4. 7. 4 Climatic Zone 0°C 0°C [-20 - 30]°C (visible by setting par 4.2.7 = 1) 4. 7. 5 Auto Slope Adaptation 0 0 (visible by setting par 4.2.7 or 5.2.7 = 1) 0 = OFF ¦ 1 = ON 4. 8 Advanced settings 4. 8. 3 Heating controller 2 2 0 = None ¦ 1 = Room thermostat ¦ 2 = Room Sensor 4. 8. 4 Cooling controller 1 1 (always visible by setting par 1.8.0 = 1) 0 = None ¦ 1 = Room thermostat ¦ 2 = Room Sensor 4. 8. 7 Humidity Control Threshold 70% 70% [40 - 100]% (visible by setting par 1.8.0 = 1) 4. 8. 8 Humidity Control Hysteresis 10% 10% [0 - 30]% (visible by setting par 1.8.0 = 1) 4. 8. 9 Humidity Alarm 0 0 (visible by setting par 1.8.0 = 1) 0 = None ¦ 1 = Stop 5 Zone 2 parameters 5. 0 Setpoint 5. 0. 0 T Day 19°C Heat - 24°C 19°C Heat - 24°C Cool Cool [10 - 30]°C 5. 0. 1 T Night 13°C Heat - 30°C 13°C Heat - 30°C Cool Cool [10 - 30]°C 5. 0. 2 T set Z2 40°C [HT] - 20°C 40°C [HT] - 20°C [LT ] [LT ] [20 - 45]°C 5. 0. 3 Zone frost temperature 5°C 5°C [2 - 15]°C 5. 1 Automatic winter mode 5. 1. 0 Automatic winter mode activation 0 0 0 = OFF ¦ 1 = ON 5. 1. 1 Automatic winter mode threshold 20°C 20°C [0 - 30]°C 5. 1. 2 Automatic winter mode delay time 300min 300min [0 - 600]min 5. 2 Settings 5. 2. 0 Zone temperature range 0 0 (0 = [LT]; 1 = [HT]) 0 = Low Temp ¦ 1 = High Temp 5. 2. 1 Thermoregulation 1 1 0 = Fix Flow T ¦ 1 = Basic Thermoreg ¦ 2 = Room T Only ¦ 3 = Outdoor T Only ¦ 4 = Room+Outdoor T 5. 2. 2 Slope 0.6 [LT] or 1.5 0.6 [LT] or 1.5 [0,2 [LT] or 0,4 [HT] - 1 [LT]or 3,5 [HT]] (visible by setting par [HT] [HT] 4.2.7 = 0) 66 / EN
Commissioning Parameter Description Default Default (IDU: M) (IDU: L) Range - Value 5. 2. 3 Offset 0°C 0°C [-7 [LT] or -14 [HT] - 7 [LT] or 14 [HT]]°C 5. 2. 4 Room Influence Proportional 2 [LT] or 10 [HT] 2 [LT] or 10 [HT] [0 - 20] (visible by setting par 4.2.7 = 0) 5. 2. 5 Max T 60°C [HT] or 45°C 60°C [HT] or 45°C [LT ] [LT ] [20 - 70 [HT] or 45 [LT]]°C 5. 2. 6 Min T 20°C[HT] or 20°C[HT] or 20°C[LT] 20°C[LT] [20 - 60 [HT] or 45 [LT]]°C 5. 2. 7 Thermoregulation logic 0 0 0 = Classic ¦ 1 = Smart 5. 2. 8 Quick night setback 0 0 0 = OFF ¦ 1 = ON 5. 2. 9 Heat request mode 0 0 0 = Standard ¦ 1 = RT Time Programs Exclusion ¦ 2 = Forcing Heat Demand 5. 3 Diagnostics 5. 3. 0 Room T °C 5. 3. 1 Room T setpoint °C 5. 3. 2 Flow temperature °C (Visible only with Zone Module) 5. 3. 3 Return temperature °C (Visible only with Zone Module) 5. 3. 4 Heat Request Z2 0 = OFF ¦ 1 = ON 5. 3. 5 Pump status (Visible only with Zone Module) 0 = OFF ¦ 1 = ON 5. 3. 7 Relative humidity % 5. 3. 8 Zone flow temperature setpoint °C 5. 4 Zone module settings (Visible only with Zone Module) 5. 4. 0 Zone pump modulation 0 = Fixed ¦ 1 = Modulating on DeltaT ¦ 2 = Modulating on pressure 5. 4. 1 Target deltaT for pump modulation 20°C [HT] or 7°C 20°C [HT] or 7°C [LT ] [LT ] [4 - 25]°C 5. 4. 2 Pump fixed speed 1 1 [0.2 - 1]% 5. 5 Cooling (always visible by setting par 1.8.0 = 1) 5. 5. 0 T Set Cool 7°C[FC] or 7°C[FC] or 18°C[UFH] 18°C[UFH] [par 5.5.7 - par 5.5.6]°C 5. 5. 1 Cooling Temp Range 1 1 (0 = [FC]; 1 = [UFH]) 0 = Fan Coil ¦ 1 = Underfloor 5. 5. 2 Thermoregulation 0 0 0 = ON/OFF Thermostat ¦ 1 = Fix Flow T ¦ 2 = Outdoor T Only 5. 5. 3 Slope 25 [FC] or 20 25 [FC] or 20 [UFH] [UFH] [18 [FC] or 0 [UFH] - 33 [FC] or 60 [UFH]] 5. 5. 4 Offset 0°C 0°C [-2,5 - 2,5]°C 5. 5. 6 Max T 12°C [FC] 23°C 12°C [FC] 23°C [UFH] [UFH] [7 [FC] or 18 [UFH] - 15 [FC] or 23°[UFH]]°C 5. 5. 7 Min T 7°C [FC] 18°C 7°C [FC] 18°C [UFH] [UFH] [7 [FC] or 15 [UFH] - 12 [FC] or 23 [UFH]]°C 5. 5. 8 Target deltaT for pump modulation 5°C 5°C [4 - 20]°C (Visible only with Zone Module) 5. 7 Zone regulation parameters (visible by setting par 4.2.7 or 5.2.7 = 1) 5. 7. 0 Heating Type 0 0 (visible by setting par 4.2.7 = 1) 0 = Floor Heating ¦ 1 = Radiators ¦ 2 = Floor Heating (main) + Radiators ¦ 3 = Radiators (main) + Floor Heating ¦ 4 = Convection ¦ 5 = Air Heating 5. 7. 1 Room Influence 0 0 (visible by setting par 4.2.7 = 1) 0 = OFF ¦ 1 = Less ¦ 2 = Medium ¦ 3 = More 5. 7. 2 Building Isolation Level 0 0 (visible by setting par 4.2.7 = 1) 0 = Poor ¦ 1 = Average ¦ 2 = Good 5. 7. 3 Building Size 0 0 (visible by setting par 4.2.7 = 1) 0 = Small ¦ 1 = Average ¦ 2 = Large 5. 7. 4 Climatic Zone 0°C 0°C [-20 - 30]°C (visible by setting par 4.2.7 = 1) 5. 7. 5 Auto Slope Adaptation 0 0 (visible by setting par 4.2.7 or 5.2.7 = 1) 0 = OFF ¦ 1 = ON 5. 8 Advanced settings 5. 8. 3 Heating controller 2 2 0 = None ¦ 1 = Room thermostat ¦ 2 = Room Sensor 5. 8. 4 Cooling controller 1 1 (always visible by setting par 1.8.0 = 1) 0 = None ¦ 1 = Room thermostat ¦ 2 = Room Sensor 5. 8. 7 Humidity Control Threshold 70% 70% [40 - 100]% (visible by setting par 1.8.0 = 1) 5. 8. 8 Humidity Control Hysteresis 10% 10% [0 - 30]% (visible by setting par 1.8.0 = 1) 5. 8. 9 Humidity Alarm 0 0 (visible by setting par 1.8.0 = 1) 0 = None ¦ 1 = Stop 7 Zone Module (Visible only with Zone Module) 7. 1 Manual mode (Visible only with Zone Module) 7. 1. 0 Manual mode activation 0 0 0 = OFF ¦ 1 = ON 7. 1. 1 Z1 Pump control 0 0 0 = OFF ¦ 1 = ON 7. 1. 2 Z2 Pump control 0 0 0 = OFF ¦ 1 = ON 7. 1. 3 Z3 Pump control 0 0 0 = OFF ¦ 1 = ON 7. 1. 4 Z2 Mix Valve Control 0 0 0 = OFF ¦ 1 = Open ¦ 2 = Close 7. 1. 5 Z3 Mix Valve Control 0 0 0 = OFF ¦ 1 = Open ¦ 2 = Close 7. 1. 6 Z1 Mix Valve Control 0 0 0 = OFF ¦ 1 = Open ¦ 2 = Close 7. 2 General Zone Module 7. 2. 0 Hydraulic scheme 0 0 0 = Not defined ¦ 1 = MCD ¦ 2 = MGM II ¦ 3 = MGM III ¦ 4 = MGZ I ¦ 5 = MGZ II ¦ 6 = MGZ III 7. 2. 1 FlowT Offset 1°C 1°C [0 - 40]°C 7. 2. 2 Auxiliary output setting 0 0 0 = Heat request ¦ 1 = External pump ¦ 2 = Alarm 7. 2. 3 External temperature correction 0°C 0°C [-3 - 3]°C EN / 67
NIMBUS COMPACT UK M NET R32 3302561
Contents 1. Safety advices 1.1
a a a a a a a When connecting the c
Safety advices 1.3 Symbols affixed
Description of the system 2.1.2 Dim
Description of the system 2.2 Indoo
Description of the system 2.2.2 Dim