MAINTENANCE GUIDE Primary Heat exchanger Maintenance Interval: Annually How : Visual inspection / Clean as necessary Condensate trap Maintenance Interval: Annually or after cleaning primary heat exchanger How : Visual inspection / Clean as necessary / Add water before replacing Pump Maintenance Interval: At the first ignition and annually How: Check that the AAV is open / Visual inspection / Clean as necessary / 70 420011270900 - Rev. 04 - 072024
TECHNICAL DATA GENERAL POWER SPECIFICATIONS EMISSIONS HEATING CIRCUIT DOMESTIC HOT WATER CIRCUIT Model: CE Certification (pin) ALTEAS ONE+ NET GENUS ONE+ WIFI 24 30 35 0085CU0034 Gas category II2HY203P Boiler type C13(X)-C23-C33(X)-C43(X)-C53(X)-C63(X) C83(X)-C93(X) B23-B23P-B33 Max/min nominal calorific flow rate G20 (Pci) Qn kW 22.0 / 2.6 28.0 / 3.0 31.0 / 3.5 Max/min nominal calorific flow rate G20 (Pcs) Qn kW 24.4 / 2.9 31.1 / 3.3 34.4 / 3.9 D.H.W. max/min nominal calorific flow rate G20 (Pci) Qn kW 26.0 / 2.6 30.0 / 3.0 34.5 / 3.5 D.H.W. max/min nominal calorific flow rate G20 (Pcs) Qn kW 28.9 / 2.9 33.3 / 3.3 38.3 / 3.9 Max/min power output G20 (80°C-60°C) Pn kW 21.5 / 2.5 27.5 / 2.8 30.3 / 3.3 Max/min power output G20 (50°C-30°C) Pn kW 23.6 / 2.7 30.3 / 3.1 33.5 / 3.6 D.H.W. max/min power output G20 Pn kW 24.9 / 2.5 28.7 / 2,9 33.1 / 3.4 Max/min nominal calorific flow rate G31 (Pci) Qn kW 22.0 / 3.3 28.0 / 3.8 31.0 / 4.3 Max/min nominal calorific flow rate G31 (Pcs) Qn kW 23.9 / 3.6 30.4 / 4.1 33.7 / 4.7 D.H.W. max/min nominal calorific flow rate G31 (Pci) Qn kW 26.0 / 3.3 30.0 / 3.8 34.5 / 4.3 D.H.W. max/min nominal calorific flow rate G31 (Pcs) Qn kW 28.3 / 3.6 32.6 / 4.1 37.5 / 4.7 Max/min power output G31 (80°C-60°C) Pn kW 21.5 / 3.1 27.5 / 3.6 30.3 / 4.0 Max/min power output G31 (50°C-30°C) Pn kW 23.6 / 3.4 30.3 / 4.0 33.4 / 4.5 D.H.W. max/min power output G31 Pn kW 24.9 / 3.2 28.7 / 3.6 33.1 / 4.1 Combustion efficiency (of flue gas) % 97.9 97.9 97.9 Nominal calorific flow rate efficiency (60/80°C) Hi/Hs % 98.2 / 88.4 98.6 / 88.8 98.1 / 88.3 Nominal calorific flow rate efficiency (30/50°C) Hi/Hs % 107.3 / 96.6 108.3 / 97.6 107.8 / 97.1 Efficiency at 30% at 30°C (condensation) Hi/Hs % 109.5 / 98.6 109.3 / 98.5 109.3 / 98.5 Minimum calorific flow rate efficiency (60/80°C) Hi/Hs % 95.1 / 85.6 94.6 / 85.2 94.2 / 84.8 Efficiency rating (dir. 92/42/EEC) stars ★★★★ Sedbuk Band Rating 2005 band/% A / 90.3 A / 90.5 A / 90.3 Sedbuk Band Rating 2009 band/% A / 89.4 A / 89.4 A / 89.3 Loss of burner gas when operating % 2.1 2.1 2.1 Available air pressure Pa 100 NoX class class 6 Flue gas temperature (G20) (80°C-60°C) °C 61 61 61 Max/min CO2 content (G20) (80°C-60°C) % 8.7 / 8.2 Max/min CO2 content (G31 (80°C-60°C) % 10.0 / 9.1 CO content (0%O2) (80°C-60°C) ppm 112 107 94 O2 content (G20) (80°C-60°C) % 5.0 4.9 5.5 Max/min flue gas flow (G20) (80°C-60°C) Kg/h 44.1 / 4.6 50.8 / 5.1 60.2 / 6.4 Max/min flue gas flow (G31) (80°C-60°C) Kg/h 43.8 / 6.0 50.9 / 7.1 57.8 / 8.0 Excess air (80°C-60°C) % 31 31 35 Expansion chamber inflation pressure bar 1 Maximum heating pressure bar 3 Expansion chamber capacity l 8 Min/max heating temperature (high temperature range) °C 35 / 82 Min/max heating temperature (low temperature range) °C 20 / 45 Domestic hot water max/min temperature °C 36 / 60 Specific flow rate of domestic hot water (∆T=30°C) l/min 12.8 14.3 16.5 Quantity of hot water ∆T=25°C l/min 15.4 17.2 19.8 Quantity of hot water ∆T=35°C l/min 11.0 12.3 14.1 Hot water comfort rating (EN13203) stars ★★★ Hot water minimum flow rate l/min 2 2 2 Domestic hot water max/min pressure bar 7.0 / 0.2 Installation and servicing instructions / 71
INSTALLATION AND SERVICING INSTRUCT
OVERVIEW These instructions are sui
OVERVIEW SAFETY REGULATION Key to s
PRODUCT DESCRIPTION CONTROL PANNEL
PRODUCT DESCRIPTION OVERALL DIMENSI
INSTALLATION Flue Detailed informat
INSTALLATION Codensate Discharge Th
INSTALLATION 5. External terminatio
INSTALLATION Gas connection Make su
Loading...
Loading...
MAINTENANCE GUIDE Primary Heat exchanger Maintenance Interval: Annually How : Visual inspection / Clean as necessary Condensate trap Maintenance Interval: Annually or after cleaning primary heat exchanger How : Visual inspection / Clean as necessary / Add water before replacing Pump Maintenance Interval: At the first ignition and annually How: Check that the AAV is open / Visual inspection / Clean as necessary / 70 420011270900 - Rev. 04 - 072024
TECHNICAL DATA GENERAL POWER SPECIFICATIONS EMISSIONS HEATING CIRCUIT DOMESTIC HOT WATER CIRCUIT Model: CE Certification (pin) ALTEAS ONE+ NET GENUS ONE+ WIFI 24 30 35 0085CU0034 Gas category II2HY203P Boiler type C13(X)-C23-C33(X)-C43(X)-C53(X)-C63(X) C83(X)-C93(X) B23-B23P-B33 Max/min nominal calorific flow rate G20 (Pci) Qn kW 22.0 / 2.6 28.0 / 3.0 31.0 / 3.5 Max/min nominal calorific flow rate G20 (Pcs) Qn kW 24.4 / 2.9 31.1 / 3.3 34.4 / 3.9 D.H.W. max/min nominal calorific flow rate G20 (Pci) Qn kW 26.0 / 2.6 30.0 / 3.0 34.5 / 3.5 D.H.W. max/min nominal calorific flow rate G20 (Pcs) Qn kW 28.9 / 2.9 33.3 / 3.3 38.3 / 3.9 Max/min power output G20 (80°C-60°C) Pn kW 21.5 / 2.5 27.5 / 2.8 30.3 / 3.3 Max/min power output G20 (50°C-30°C) Pn kW 23.6 / 2.7 30.3 / 3.1 33.5 / 3.6 D.H.W. max/min power output G20 Pn kW 24.9 / 2.5 28.7 / 2,9 33.1 / 3.4 Max/min nominal calorific flow rate G31 (Pci) Qn kW 22.0 / 3.3 28.0 / 3.8 31.0 / 4.3 Max/min nominal calorific flow rate G31 (Pcs) Qn kW 23.9 / 3.6 30.4 / 4.1 33.7 / 4.7 D.H.W. max/min nominal calorific flow rate G31 (Pci) Qn kW 26.0 / 3.3 30.0 / 3.8 34.5 / 4.3 D.H.W. max/min nominal calorific flow rate G31 (Pcs) Qn kW 28.3 / 3.6 32.6 / 4.1 37.5 / 4.7 Max/min power output G31 (80°C-60°C) Pn kW 21.5 / 3.1 27.5 / 3.6 30.3 / 4.0 Max/min power output G31 (50°C-30°C) Pn kW 23.6 / 3.4 30.3 / 4.0 33.4 / 4.5 D.H.W. max/min power output G31 Pn kW 24.9 / 3.2 28.7 / 3.6 33.1 / 4.1 Combustion efficiency (of flue gas) % 97.9 97.9 97.9 Nominal calorific flow rate efficiency (60/80°C) Hi/Hs % 98.2 / 88.4 98.6 / 88.8 98.1 / 88.3 Nominal calorific flow rate efficiency (30/50°C) Hi/Hs % 107.3 / 96.6 108.3 / 97.6 107.8 / 97.1 Efficiency at 30% at 30°C (condensation) Hi/Hs % 109.5 / 98.6 109.3 / 98.5 109.3 / 98.5 Minimum calorific flow rate efficiency (60/80°C) Hi/Hs % 95.1 / 85.6 94.6 / 85.2 94.2 / 84.8 Efficiency rating (dir. 92/42/EEC) stars ★★★★ Sedbuk Band Rating 2005 band/% A / 90.3 A / 90.5 A / 90.3 Sedbuk Band Rating 2009 band/% A / 89.4 A / 89.4 A / 89.3 Loss of burner gas when operating % 2.1 2.1 2.1 Available air pressure Pa 100 NoX class class 6 Flue gas temperature (G20) (80°C-60°C) °C 61 61 61 Max/min CO2 content (G20) (80°C-60°C) % 8.7 / 8.2 Max/min CO2 content (G31 (80°C-60°C) % 10.0 / 9.1 CO content (0%O2) (80°C-60°C) ppm 112 107 94 O2 content (G20) (80°C-60°C) % 5.0 4.9 5.5 Max/min flue gas flow (G20) (80°C-60°C) Kg/h 44.1 / 4.6 50.8 / 5.1 60.2 / 6.4 Max/min flue gas flow (G31) (80°C-60°C) Kg/h 43.8 / 6.0 50.9 / 7.1 57.8 / 8.0 Excess air (80°C-60°C) % 31 31 35 Expansion chamber inflation pressure bar 1 Maximum heating pressure bar 3 Expansion chamber capacity l 8 Min/max heating temperature (high temperature range) °C 35 / 82 Min/max heating temperature (low temperature range) °C 20 / 45 Domestic hot water max/min temperature °C 36 / 60 Specific flow rate of domestic hot water (∆T=30°C) l/min 12.8 14.3 16.5 Quantity of hot water ∆T=25°C l/min 15.4 17.2 19.8 Quantity of hot water ∆T=35°C l/min 11.0 12.3 14.1 Hot water comfort rating (EN13203) stars ★★★ Hot water minimum flow rate l/min 2 2 2 Domestic hot water max/min pressure bar 7.0 / 0.2 Installation and servicing instructions / 71
INSTALLATION AND SERVICING INSTRUCT
OVERVIEW These instructions are sui
OVERVIEW SAFETY REGULATION Key to s
PRODUCT DESCRIPTION CONTROL PANNEL
PRODUCT DESCRIPTION OVERALL DIMENSI
INSTALLATION Flue Detailed informat
INSTALLATION Codensate Discharge Th
INSTALLATION 5. External terminatio
INSTALLATION Gas connection Make su
Loading...
Loading...
X