Ariston Genus ONE+ WiFi Installation and Servicing Manual

TECHNICAL AREA TECHNICAL

TECHNICAL AREA TECHNICAL AREA - reserved for qualified technician Accessing the Technical Area allows for setting/configuring the device according to the specific requirements of every installation procedure. It also provides important information relating to the efficient operation of the boiler. The Technical Area comprises various display windows that allow for directly accessing the parameters Intervening in each single product installation/configuration phase. The parameters relating to each single menu are listed in the following pages. The various parameters can be accessed and modified using the button , the programming Keys b and the ESC button (see picture below). a. ESC button (Back) b. Programming keys c. OK button 26/10/15 12:30 20,5° 3 00 02 04 06 08 10 12 14 16 18 20 22 24 40° 1,5 bar 70° COMFORT CASCADE AUTO Central Heating For accessing the Technical Area simultaneously press the ESC and buttons for 5 seconds; the display will visualise the request for entering the technical code. Press the programming key b the button . to select 234 and press To move within the Technical Area, press the programming key b and press button to access the selected window. Press the programming key b to select a parameter and press button to access it. To modify the value of a parameter, press the programming key b and press button to store the value. Use the ESC button to exit a parameter without storing the modification and for returning to the normal viewing mode. 10° a b b c Insert code Insert technical code 222 Save Example: Modification of parameter 2.3.1 Max. Adjustable Central Heating Power Proceed as follows: 1. Simultaneously press the ESC and buttons for 5 seconds; the display will visualise the request for entering the technical code. 2. Press the programming key b Technical area Language, date and time and select code 234. Complete Menu 3. Press the button; the Configuration Wizard display will visualise the available windows. Service Faults 4. Press the programming key b to select the Complete Menu. 5. Press the button to access; the display will Menu visualise the available menus. 0 Network 1 6. Press the programming key b 2 Boiler Parameters to select Menu 3 4 Zone1 Parameters 2 - Boiler parameters. 7. Press the button. The 2 Boiler Parameters display will visualise the 2.0 General available sub-menus. 2.1 Free parameters 2.2 Settings 8. Press the programming key b 2.3 Central Heating-1 to select 2.3 - Central heating 1. 2.4 Central Heating-2 9. Press the button to 2.3 Central Heating-1 access. 2.3.0 Max CH Absolute 62 The display will visualise the 2.3.1 Max CH Adjustable 50 2.3.2 parameters relative to submenu 2.3. 2.3.4 2.3.3 10. Press the programming key b to select parameter 2.3.1 Max CH Adjustable 2.3.1 - Max. C.H. Adjustable. 50 % 11. Press the button to access the parameter. Maximum value 100% Minimum value 0% The display will visualise the value of the parameter (50%) 2.3.1 Max CH Adjustable in addition to the minimum and maximum values 46 % allowed. 12. Press the programming key Maximum value 100% Minimum value 0% b to select the new value, e.g. 46%. 13. Press the button to store the modification. (To exit the parameter without storing the modification, press the ESC button). 14. Press the ESC button to return to the normal viewing mode. Technical area Language, date and time Complete Menu Configuration Wizard Service Faults / 42 420011270900 - Rev. 04 - 072024

TECHNICAL AREA COMPLETE MENU STRUCTURE Tecnical Area Service code (reserved for qualified technicians) - Press the programming key b > to select 234 and press the button . Language, date and time - Follow the instructions of the display. Press OK button at each entry to save COMPLETE MENU - The parameters relating to each individual menu are listed in the following pages. Configuration Wizard Boiler Configuration parameters Gas Parameter Direct access to the parameters 220 - 230 - 231 - 232 - 233 - 234 - 270 Settings Direct access to the parameters 220 - 231 - 223 - 238 - 245 - 246 Visualization Direct access to the parameters 821 - 822 - 823 - 824 - 825 - 827 - 830 - 831 - 832 - 833 - 840 - 835 - 874 Zone Direct access to the parameters 402 - 502 - 602 - 420 - 520 - 620 - 434 - 534 - 634 - 830 Guided procedures System Filling System air purge Exhaust fumes analysis CO2 calibration Service options Service Center Data - To insert the name and phone number of Service Center The data appears in the display in case of error Enable service warnings Service warning reset Months remaining before Service Test mode Pump test 3 way valve Test Fan test Parametrization (see NOTE 1) CH flow rate (see NOTE 2) DHW flow rate reference (see NOTE 2) Service Boiler Configuration parameters Gas parameter Direct access to the parameters 220 - 230 - 231 - 232 - 233 - 234 - 270 Visualization Direct access to the parameters 821 - 822 - 824 - 825 - 827 - 830 - 831 - 832 - 833 - 840 - 835 Boiler PCB change Direct access to the parameters 220 - 226 - 228 -229 - 231 - 232 - 233 - 234 - 247 - 250 - 253 Automatic Calibration - see page 18 Pump parameter - Reset value Faults - The display shows the last 10 errors with details of the code, description and date. Turn the encoder to scroll the errors NOTE 1 - Parametrization PARAMETERS BACK-UP FOR PCB AND DISPLAY REPLACEMENT This function enable the boiler to automatically store, each 2 hours, the parameters back-up in the display internal flash memory. Thanks to this function during the PCB replacement is possible restore the previous parameters setting. Read the instructions manual for changing the Main PCB, Display PCB or Display. NOTE 2 - Flow Rate Functions Through the Flow Rate Functions it’s possible to check circulation in different conditions. The DHW flow rate function can be used to detect obstructions that reduce the flow rate value of the internal boiler circuit (i.e. due to plate heat exchanger clogging). Thanks to CH flow rate function it’s possible to perform the central heating balancing. Installation and servicing instructions / 43

INSTALLATION MANUALS

Views
8 months ago

Genus ONE+ WiFi Installation Manual

  • Text
  • Wwwaristoncom
  • Manual
  • Wifi
  • Genus
  • Maintenance
  • Efficiency
  • Appliance
  • Flue
  • Installation
  • Heating
  • Boiler
Ariston Genus ONE+ WiFi Installation and Servicing Manual

TECHNICAL AREA TECHNICAL

TECHNICAL AREA TECHNICAL AREA - reserved for qualified technician Accessing the Technical Area allows for setting/configuring the device according to the specific requirements of every installation procedure. It also provides important information relating to the efficient operation of the boiler. The Technical Area comprises various display windows that allow for directly accessing the parameters Intervening in each single product installation/configuration phase. The parameters relating to each single menu are listed in the following pages. The various parameters can be accessed and modified using the button , the programming Keys b and the ESC button (see picture below). a. ESC button (Back) b. Programming keys c. OK button 26/10/15 12:30 20,5° 3 00 02 04 06 08 10 12 14 16 18 20 22 24 40° 1,5 bar 70° COMFORT CASCADE AUTO Central Heating For accessing the Technical Area simultaneously press the ESC and buttons for 5 seconds; the display will visualise the request for entering the technical code. Press the programming key b the button . to select 234 and press To move within the Technical Area, press the programming key b and press button to access the selected window. Press the programming key b to select a parameter and press button to access it. To modify the value of a parameter, press the programming key b and press button to store the value. Use the ESC button to exit a parameter without storing the modification and for returning to the normal viewing mode. 10° a b b c Insert code Insert technical code 222 Save Example: Modification of parameter 2.3.1 Max. Adjustable Central Heating Power Proceed as follows: 1. Simultaneously press the ESC and buttons for 5 seconds; the display will visualise the request for entering the technical code. 2. Press the programming key b Technical area Language, date and time and select code 234. Complete Menu 3. Press the button; the Configuration Wizard display will visualise the available windows. Service Faults 4. Press the programming key b to select the Complete Menu. 5. Press the button to access; the display will Menu visualise the available menus. 0 Network 1 6. Press the programming key b 2 Boiler Parameters to select Menu 3 4 Zone1 Parameters 2 - Boiler parameters. 7. Press the button. The 2 Boiler Parameters display will visualise the 2.0 General available sub-menus. 2.1 Free parameters 2.2 Settings 8. Press the programming key b 2.3 Central Heating-1 to select 2.3 - Central heating 1. 2.4 Central Heating-2 9. Press the button to 2.3 Central Heating-1 access. 2.3.0 Max CH Absolute 62 The display will visualise the 2.3.1 Max CH Adjustable 50 2.3.2 parameters relative to submenu 2.3. 2.3.4 2.3.3 10. Press the programming key b to select parameter 2.3.1 Max CH Adjustable 2.3.1 - Max. C.H. Adjustable. 50 % 11. Press the button to access the parameter. Maximum value 100% Minimum value 0% The display will visualise the value of the parameter (50%) 2.3.1 Max CH Adjustable in addition to the minimum and maximum values 46 % allowed. 12. Press the programming key Maximum value 100% Minimum value 0% b to select the new value, e.g. 46%. 13. Press the button to store the modification. (To exit the parameter without storing the modification, press the ESC button). 14. Press the ESC button to return to the normal viewing mode. Technical area Language, date and time Complete Menu Configuration Wizard Service Faults / 42 420011270900 - Rev. 04 - 072024

TECHNICAL AREA COMPLETE MENU STRUCTURE Tecnical Area Service code (reserved for qualified technicians) - Press the programming key b > to select 234 and press the button . Language, date and time - Follow the instructions of the display. Press OK button at each entry to save COMPLETE MENU - The parameters relating to each individual menu are listed in the following pages. Configuration Wizard Boiler Configuration parameters Gas Parameter Direct access to the parameters 220 - 230 - 231 - 232 - 233 - 234 - 270 Settings Direct access to the parameters 220 - 231 - 223 - 238 - 245 - 246 Visualization Direct access to the parameters 821 - 822 - 823 - 824 - 825 - 827 - 830 - 831 - 832 - 833 - 840 - 835 - 874 Zone Direct access to the parameters 402 - 502 - 602 - 420 - 520 - 620 - 434 - 534 - 634 - 830 Guided procedures System Filling System air purge Exhaust fumes analysis CO2 calibration Service options Service Center Data - To insert the name and phone number of Service Center The data appears in the display in case of error Enable service warnings Service warning reset Months remaining before Service Test mode Pump test 3 way valve Test Fan test Parametrization (see NOTE 1) CH flow rate (see NOTE 2) DHW flow rate reference (see NOTE 2) Service Boiler Configuration parameters Gas parameter Direct access to the parameters 220 - 230 - 231 - 232 - 233 - 234 - 270 Visualization Direct access to the parameters 821 - 822 - 824 - 825 - 827 - 830 - 831 - 832 - 833 - 840 - 835 Boiler PCB change Direct access to the parameters 220 - 226 - 228 -229 - 231 - 232 - 233 - 234 - 247 - 250 - 253 Automatic Calibration - see page 18 Pump parameter - Reset value Faults - The display shows the last 10 errors with details of the code, description and date. Turn the encoder to scroll the errors NOTE 1 - Parametrization PARAMETERS BACK-UP FOR PCB AND DISPLAY REPLACEMENT This function enable the boiler to automatically store, each 2 hours, the parameters back-up in the display internal flash memory. Thanks to this function during the PCB replacement is possible restore the previous parameters setting. Read the instructions manual for changing the Main PCB, Display PCB or Display. NOTE 2 - Flow Rate Functions Through the Flow Rate Functions it’s possible to check circulation in different conditions. The DHW flow rate function can be used to detect obstructions that reduce the flow rate value of the internal boiler circuit (i.e. due to plate heat exchanger clogging). Thanks to CH flow rate function it’s possible to perform the central heating balancing. Installation and servicing instructions / 43