Ariston Genus ONE+ WiFi Installation and Servicing Manual

INSTALLATION Cube Room

INSTALLATION Cube Room sensor (wireless) Connection To connect a room thermostat, read the instructions present in the kit delivered with the gas boiler. DO NOT CONNECT 240V TO ANY PERIPHERAL CONNECTIONS Room Thermostat / Remote Clock Connection To connect a room thermostat, it is necessary to: 1. Open the control panel 2. Loosen the cable clamp using a screwdriver and insert the wires leading from the room thermostat 3. Connect the wires to the terminals as indicated in the figure below, removing the link 4. If a remote time clock is to be fitted, using a volt free switching time clock connect the switching wires from the time clock following points 1 - 3 above 5. If using an external time clock and room thermostat, these must be connected in series as shown in diagram C, 6. Ensure that they are well connected and not subject to stress when the control panel is closed DO NOT CONNECT 240V TO ANY PERIPHERAL CONNECTIONS Connector TA on PCB (low voltage switching) Connector TA on PCB (low voltage switching) Connector TA on PCB (low voltage switching) / 28 420011270900 - Rev. 04 - 072024

MADE IN ITALY MADE IN ITALY INSTALLATION Electrical diagram For increased safety, ask a qualified technician to perform a thorough check of the electrical system. The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply. 1 2 1 2 3 GATEWAY WIFI Bk Bk Bl Bk Br 2 1 3 2 1 CN16 CN9 Bl CUBE ALTEAS ONE+ NET 9 Bk 8 Bk 1 1 CN22 CN15 CN21 230 V 230 V T B 230 V 230 V 230 V 230 V TA2 BUS FLOOR SE TNK SOL TA1 N L 1 10 1 CN20 CN17 CN23 1 CN16 1 2 3 4 5 Bk Bk Bl Br Bl Rd Br Rd Bk Wh CN13 CN14 1 1 CN10 1 1 CN1 6 Bk 1 CN7 CN9 Bl Bk Br 1. Central Heating Return Temperature Probe 2. Central Heating Flow Temperature Probe 3. D.H.W. Flow Switch 4. Water pressure sensor 5. Diverter valve 6. Gas Valve 7. Modulating Circulation Pump with air release valve 8. Modulating Fan 9. Detection/Ignition electrode 10 Spark generator Bk= Black Rd = Red Gr = Green Bl = Blue Br = Brown Wh = White Gry = Grey Installation and servicing instructions / 29

INSTALLATION MANUALS

Views
9 months ago

Genus ONE+ WiFi Installation Manual

  • Text
  • Wwwaristoncom
  • Manual
  • Wifi
  • Genus
  • Maintenance
  • Efficiency
  • Appliance
  • Flue
  • Installation
  • Heating
  • Boiler
Ariston Genus ONE+ WiFi Installation and Servicing Manual

INSTALLATION Cube Room

INSTALLATION Cube Room sensor (wireless) Connection To connect a room thermostat, read the instructions present in the kit delivered with the gas boiler. DO NOT CONNECT 240V TO ANY PERIPHERAL CONNECTIONS Room Thermostat / Remote Clock Connection To connect a room thermostat, it is necessary to: 1. Open the control panel 2. Loosen the cable clamp using a screwdriver and insert the wires leading from the room thermostat 3. Connect the wires to the terminals as indicated in the figure below, removing the link 4. If a remote time clock is to be fitted, using a volt free switching time clock connect the switching wires from the time clock following points 1 - 3 above 5. If using an external time clock and room thermostat, these must be connected in series as shown in diagram C, 6. Ensure that they are well connected and not subject to stress when the control panel is closed DO NOT CONNECT 240V TO ANY PERIPHERAL CONNECTIONS Connector TA on PCB (low voltage switching) Connector TA on PCB (low voltage switching) Connector TA on PCB (low voltage switching) / 28 420011270900 - Rev. 04 - 072024

MADE IN ITALY MADE IN ITALY INSTALLATION Electrical diagram For increased safety, ask a qualified technician to perform a thorough check of the electrical system. The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply. 1 2 1 2 3 GATEWAY WIFI Bk Bk Bl Bk Br 2 1 3 2 1 CN16 CN9 Bl CUBE ALTEAS ONE+ NET 9 Bk 8 Bk 1 1 CN22 CN15 CN21 230 V 230 V T B 230 V 230 V 230 V 230 V TA2 BUS FLOOR SE TNK SOL TA1 N L 1 10 1 CN20 CN17 CN23 1 CN16 1 2 3 4 5 Bk Bk Bl Br Bl Rd Br Rd Bk Wh CN13 CN14 1 1 CN10 1 1 CN1 6 Bk 1 CN7 CN9 Bl Bk Br 1. Central Heating Return Temperature Probe 2. Central Heating Flow Temperature Probe 3. D.H.W. Flow Switch 4. Water pressure sensor 5. Diverter valve 6. Gas Valve 7. Modulating Circulation Pump with air release valve 8. Modulating Fan 9. Detection/Ignition electrode 10 Spark generator Bk= Black Rd = Red Gr = Green Bl = Blue Br = Brown Wh = White Gry = Grey Installation and servicing instructions / 29