MAINTENANCE GUIDE

MAINTENANCE GUIDE Cleaning the trap The trap is accessed by emptying the condensate bowl located in the bottom section. Wash with water and detergent. Replace the condensate collection bowl in its housing. NB: In the event of prolonged use of the appliance, the trap must be filled before being used again. A lack of water in the trap is dangerous and may cause products to be released into the atmosphere. 46 /

MAINTENANCE GUIDE 1. GENERAL ACCESS 1.0 Disconnect the boiler Before beginning maintenance work: a. Disconnect the appliance from the electricity supply. Press the ON/OFF button and wait 1 minute (the 3-way valve turn on Stand-by position) ATTENTION!! With the 3-way valve on heating position is not possible to remove the motor. Turn the external bipolar switch to the “OFF” position. b. Close the gas valve and the central heating and domestic hot water system valves. Remove the front panel 2 1 1.1 General Access Tools Lower the electrical front panel Remove the two screws TIME 3 min 1 3 CAUTION!! REMOVE ONLY THE SCREWS SHOWN IN THE PICTURE / 47