Genus ONE Net - Installation Manual

  • Text
  • Boiler
  • Heating
  • Flue
  • Appliance
  • Installation
  • Valve
  • Efficiency
  • Maintenance
  • Display
  • Maximum
  • Genus
  • Install

TECHNICAL AREA menu

TECHNICAL AREA menu sub-menu parameter description value default setings menu sub-menu parameter description value default setings 8. 2. 4 Diverter valve position 0 = D.H.W. 1 = Central Heating 8. 2. 5 D.H.W. Flow Rate (l/min) 8. 2. 7 Pump Modulation % 8. 2. 8 Gas Power (kW) 8. 3 BOILER TEMPERTURE 8. 3. 0 CH Flow set Temperature(°C) 8. 3. 1 CH Flow Temperature(°C) 8. 3. 2 CH Return Temperature(°C) 8. 3. 3 DHW Temperature (°C) 8. 3. 4 < Not Available> 8. 3. 5 Outdoor temperature (°C) Only with external sensor connected 8. 4 STORAGE 8. 4. 2 D.H.W. Inlet Temperature (°C) Display only with Solar Kit or external storage Kit 8. 5 SERVICE 8. 5. 0 Months to next maintenance from 0 to 60 (month) If setted the boiler will display that is time to call the installer for maintenance 24 19. 0. 1 Network configuration 0 = OFF 1 = ON 19. 0. 2 19. 0. 3 Internet time 0 = OFF 1 = ON 19. 1 Connectivity Info 19. 1. 0 Connectivity status 19. 1. 1 Signal level 19. 1. 2 Active Status 19. 1. 4 Serial Number 19. 1. 5 SW Upgrade Status 19. 2 Reset Menu 19. 2. 0 Factory Reset (soft reset) Do you really want to perform the reset? if you press OK button, the reset command will be executed otherwise, by way of ESC, the previous page is shown. Semnalare 3P9 ALERT intretinere programata - chemati asistenta tehnica 8. 5. 1 Maintenance on Day At 0 = OFF 1 =ON 8. 5. 2 Maintenance Warning Reset Reset? OK= Yes Esc = No to erase the advice for maintenance 8. 5. 4 SW version Interface 8. 5. 5 SW version Main 8. 6 ERROR HISTORY 8. 6. 0 Last 10 Errors from Fault 0 to Fault 9 This parameter makes it possible to see the last 10 errors shown by the boiler as well as the relevant day, month and year. Turning the encoder allows for viewing the sequence of errors that occurred, from 0 to 9. 8.6.0 Last 10 errors Fault 3 No flame detected 501 12:18 24/01/2012 8. 6. 1 Reset Error List Reset? Ok=Yes Esc=No 8. 7 FREE PARAMETERS 8. 7. 4 Boiler Flowswitch 0 = Open 1 = Closed 8. 7. 6 Safety flame sensor 19 WI - FI (only for ALTEAS ONE) 19. 0 WI-FI CONFIGURATION 19. 0. 0 Wi-Fi activation 0 = OFF 1 = ON 44 /

MAINTENANCE Important Maintenance is an essential part of the safe and efficient operation of the boiler and ensures its durability. It should be performed according to the instructions given in current legislation. Perform combustion analysis regularly in order to check the operating efficiency of the boiler and to make sure any polluting substances released are within the boundaries set by current legislation. Before beginning maintenance work: - Disconnect the appliance from the electricity supply by turning the external bipolar switch to the “OFF” position; - Close the gas valve and the central heating and domestic hot water system valves. After the work has been completed the initial settings will be restored. General comments It is recommended that the following inspections be carried out on the boiler at least once a year: 1. Check the seals in the water part and, if necessary, replace the gaskets and restore the seal to perfect working order. 2. Check the seals in the gas part and, if necessary, replace the gaskets and restore the seal to perfect working order. 3. Visually check the overall condition of the boiler. 4. Visually check and, if necessary, disassemble and clean the burner. 5. Following the inspection detailed in point “3”, disassemble and clean the combustion chamber, if necessary. 6. Following the inspection detailed in point “4”, disassemble and clean the burner, if necessary. 7. Cleaning the primary heat exchanger 8. Make sure the following heating safety devices are operating correctly: - temperature limit safety device. 9. Make sure that the following gas part safety devices are operating correctly: - absence of gas or flame safety device (ionisation). 10. Check the efficiency of the domestic hot water production process (test the flow rate and temperature). 11. Perform a general inspection of the boiler operation. 12. Remove oxide from the detection electrode using an emery cloth. 13. These checks are not exhaustive. Further mechanical, electrical and combustion maintenance checks may be required. WARNING!! THE AUTOMATIC CALIBRATION MUST BE DONE IN CASE OF: - REPLACEMENT OF: FAN, GAS VALVE, AIR/GAS MIXER, BURNER, ELECTRODE. - REPLACEMENT OF P.C.B. - GAS CHANGEOVER - ANY MODIFICATION TO THE FOLLOWING PARAMETERS 220 - SOFT IGNITION 231 - MAX CH ADJUSTABLE 232 - MAX DHW PERCENTAGE 233 - MIN PERCENTAGE 234 - MAX CH PERCENTAGE Operational test After having carried out the maintenance operations, fill the heating circuit at a pressure of approximately 1.5 bar and release the air from the system. Fill the domestic hot water system at the same time. - Begin operating the boiler. - If necessary, release the air from the heating system again. - Check the settings and make sure all the command, adjustment and monitoring parts are working correctly. - Check the flue system is sealed and operating correctly. Draining procedures The heating system must be drained using the following procedure: - Switch off the boiler, make sure the external bipolar switch is in the OFF position and shut off the gas valve; - Loosen the automatic air relief valve; - Open the system drain off cock and collect the escaping water in a container; - Empty the water from the lowest points of the system (where applicable). If the system is to be left inactive in areas where the room temperature may fall below 0°C during winter, we recommend that anti-freeze liquid is added to the water in the heating system in order to avoid the need for repeated draining; when this liquid is used make sure it is compatible with the stainless steel used for the bodywork of the boiler. We recommend the use of anti-freeze products which contain PROPYLENE GLYCOLS as these inhibit corrosion and that they are used in conjunction with the anti-scaling and anti-corrosion function, in the quantities suggested by the manufacturer, at the mimimum temperature. Regularly check the pH level of the water/anti-freeze mix in the boiler circuit and replace it when the value measured is lower than the limit prescribed by the manufacturer. DO NOT MIX DIFFERENT TYPES OF ANTI-FREEZE. The manufacturer will not be held liable for any damage caused by the appliance or the system due to the use of inappropriate anti-freeze substances or additives. Draining the domestic hot water system and indirect cylinder Every time there is a danger of freezing, the domestic hot water system must be drained as follows: - Shut off the water mains inlet valve; - Open all the hot and cold water taps; - Empty the water from the lowest points of the system (where applicable). WARNING Before handling, empty all components which may contain hot water, performing bleeding where necessary. Descale the components in accordance with the instructions provided on the safety data leaflet supplied with the product used, make sure the room is well ventilated, wear protective clothing, avoid mixing different products, and protect the appliance and surrounding objects. Seal all openings used to take a gas pressure reading or to make any gas adjustments. If a smell of burning is detected or smoke is seen leaking from the appliance, or there is a smell of gas, disconnect it from the electricity supply, shut off the gas valve, open the windows and call for technical assistance. Cleaning the primary exchanger Cleaning the combustion side The inside of the primary exchanger is accessed by removing the burner. Wash with water and detergent using a non-metallic rifle-type brush, rinse with water. / 45

MANUALS