Views
3 years ago

Genus HE 35 Plus Manual

SERVICE INTERVAL RECORD

SERVICE INTERVAL RECORD It is recommended that your heating system is serviced regularly and that you complete the appropriate Service Interval Record Below. Service Provider. Before completing the appropriate Service Interval Record below, please ensure you have carried out the service as described in the boiler manufacturer’s instructions. Always use the manufacturer’s specified spare part when replacing all controls SERVICE 1 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 2 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 3 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 4 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SERVICE 5 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SERVICE 6 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 7 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 8 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SERVICE 9 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 10 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE ✂

21. TECHNICAL INFORMATION Model GENUS HE 35 Plus CE certificate 1312-BP-4082 Performance category **** NoX class 5 Category II2H3P Heating output 80°C/60°C Kw 6 to 30 Heating output 50°C/30°C Kw 7 to 32 Variable hot water power Pn max Kw 35 Nominal gas flow rate (15 °C-1013 mbar) min max Central Heating & DHW flow rate Qn kW 7 31 G 20 (NG H -Lacq) 34,02 MJ/m 3 under 20 mbar Vr m 3 /h 0,74 3,28 G 31 (Propane) 46,4 MJ/kg 37 under mbar Vr kg/h 0,54 2,41 Membrane Diameter (mm)/marking G 20 mm without G 31 (propane) mm 5 Adjustable heating outlet temperature: °C 25 to 75 or 42 to 82 Central heating minimum flow rate I/h 300 Central heating circuit maximum pressure Pw max bar 3 Central heating expansion vessel capacity L 7,1 Expansion vessel inflation pressure bar 0,7 Adjustable hot water temperature °C 40 to 70 Stored D.H.W. cylinder capacity L 42 DHW ignition flow rate l/min. 2 DHW specific flow rate (ΔT: 30 K) D I/min. 21,0 DHW start minimum pressure Pw min bar 0,3 Maximum pressure of DHW circuit Pw max bar 7 DHW expansion vessel L 4 Electric voltage 230 volt, single phase - 50 Hz Electrical input power W 150 Electrical protection IP44 Fresh air flow rate required for combustion V m 3 h. 40 Mass flow rate for combustion products 15,5 Fume temperature (60-80) °C 67 Fume temperature (30-50) °C 60 CO2 G20 % 9 CO2 G31 % 10 Dimensions Height / Width / Depth (mm) 950 / 595 / 470 Weight kg 59 Flue duct type C13 C33 C43 C53 B23 SEDBUK Band A This appliance is suitable for Natural gas or LPG. A gas conversion must be made by a competent person. 67

Views
3 years ago

Genus HE 35 Plus Manual

SERVICE INTERVAL RECORD

SERVICE INTERVAL RECORD It is recommended that your heating system is serviced regularly and that you complete the appropriate Service Interval Record Below. Service Provider. Before completing the appropriate Service Interval Record below, please ensure you have carried out the service as described in the boiler manufacturer’s instructions. Always use the manufacturer’s specified spare part when replacing all controls SERVICE 1 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 2 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 3 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 4 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SERVICE 5 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SERVICE 6 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 7 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SERVICE 8 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SERVICE 9 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE SIGNATURE SERVICE 10 DATE ENGINEER NAME COMPANY NAME TEL No. CORGI ID CARD SERIAL No. COMMENTS SIGNATURE ✂

21. TECHNICAL INFORMATION Model GENUS HE 35 Plus CE certificate 1312-BP-4082 Performance category **** NoX class 5 Category II2H3P Heating output 80°C/60°C Kw 6 to 30 Heating output 50°C/30°C Kw 7 to 32 Variable hot water power Pn max Kw 35 Nominal gas flow rate (15 °C-1013 mbar) min max Central Heating & DHW flow rate Qn kW 7 31 G 20 (NG H -Lacq) 34,02 MJ/m 3 under 20 mbar Vr m 3 /h 0,74 3,28 G 31 (Propane) 46,4 MJ/kg 37 under mbar Vr kg/h 0,54 2,41 Membrane Diameter (mm)/marking G 20 mm without G 31 (propane) mm 5 Adjustable heating outlet temperature: °C 25 to 75 or 42 to 82 Central heating minimum flow rate I/h 300 Central heating circuit maximum pressure Pw max bar 3 Central heating expansion vessel capacity L 7,1 Expansion vessel inflation pressure bar 0,7 Adjustable hot water temperature °C 40 to 70 Stored D.H.W. cylinder capacity L 42 DHW ignition flow rate l/min. 2 DHW specific flow rate (ΔT: 30 K) D I/min. 21,0 DHW start minimum pressure Pw min bar 0,3 Maximum pressure of DHW circuit Pw max bar 7 DHW expansion vessel L 4 Electric voltage 230 volt, single phase - 50 Hz Electrical input power W 150 Electrical protection IP44 Fresh air flow rate required for combustion V m 3 h. 40 Mass flow rate for combustion products 15,5 Fume temperature (60-80) °C 67 Fume temperature (30-50) °C 60 CO2 G20 % 9 CO2 G31 % 10 Dimensions Height / Width / Depth (mm) 950 / 595 / 470 Weight kg 59 Flue duct type C13 C33 C43 C53 B23 SEDBUK Band A This appliance is suitable for Natural gas or LPG. A gas conversion must be made by a competent person. 67