commissioning AUTO function This is a function which enables the boiler to automatically adapt its operation routine (the temperature of the heating elements) in line with the outdoor conditions, in order to achieve and maintain the requested room temperature conditions. Depending on the peripheral units connected and the number of zones controlled, the boiler adjusts its flow temperature automatically. The various corresponding parameters should therefore be set (see Technical Area). To activate the function, press the AUTO button. For further information please refer to the ARISTON temperature adjustment manual. 24/01/2012 15:38 auto 44°C 38°C EXAMPLE 1: SINGLE ZONE SYSTEM (HIGH-TEMPERATURE) WITH ON/OFF ROOM THERMOSTAT: In this case the following parameters must be set: 4.2.1 - Activation of temperature adjustment using sensors - Select 04 = Basic temperature adjustment 2.4.4 - Boost Time (optional) The wait time for the flow temperature increase in steps of 4°C may be set. The value varies according to the type of system and installation. If the Boost Time value = 00 the function is not activated. EXAMPLE 2: SINGLE ZONE SYSTEM (HIGH-TEMPERATURE) WITH ON/OFF ROOM THERMOSTAT + OUTDOOR SENSOR: In this case the following parameters must be set: 4.2.1 - Activation of temperature adjustment using sensors - Select 01 = outdoor sensor only 4.2.2 - Temperature adjustment curve selection - Select the relevant curve according to the type of system, installation, heat insulation used in the building, etc. 4.2.3 - Perform a parallel curve shift if necessary, increasing or decreasing the set-point temperature (this may also be modified by the user, using the heating temperature adjustment knob, which, with the AUTO function activated, is used to shift the curve in a parallel manner). EXAMPLE 3: SINGLE ZONE SYSTEM (HIGH-TEMPERATURE) WITH SENSYS REMOTE CONTROL + OUTDOOR SENSOR In this case the following parameters must be set: 4.2.1 - Activation of temperature adjustment using sensors - select 0 = outdoor sensor + room sensor 4.2.2 - Temperature adjustment curve selection - Select the relevant curve according to the type of system, installation, heat insulation used in the building, etc 4.2.3 - Perform a parallel curve shift if necessary, increasing or decreasing the set-point temperature. (This may also be changed by the user by the encoder which, with the AUTO function activated, is used to shift the curve in a parallel manner.) 4.2.4 - Influence of room sensor - used to adjust the influence the room temperature has on the calculation of the set-point flow temperature (20 = maximum, 0 = minimum). 28
oiler protection devices The boiler is protected from malfunctions by means of internal checks performed by the electronic P.C.B., which stops the boiler from operating if necessary. In the event of the boiler being shut off in this manner, a code appears on the control panel display which refers to the type of shut-off and the reason behind it. Two types of shut-off may occur: Safety shut-off This type of error is “volatile”, which means that the boiler starts up again automatically as soon as the problem which caused the shutoff is removed. The display will visualise the error code and description. “Fault 110 - Send Probe Damaged” In fact, soon as the cause of the shut-off disappears, the boiler starts up again and continues to operate normally. If the boiler still indicates a safety shut-off, switch it off. Make sure the external electric switch is in the OFF position, shut off the gas valve and contact a qualified technician. Fault 110 Important If this shutdown occurs frequently, contact an authorised Technical Service Centre for assistance. For safety reasons, the boiler will permit a maximum of 5 resets in 15 minutes (5 presses of the RESET button); at the 6th attempt within this 15-minute period the boiler will shut down and may only be operated again after the electricity supply has been disconnected. If the shutdown is occasional or an isolated event, this is not a problem. The first figure of the error code (e.g. Errore 101) indicates within which operational assembly the error occurred. 1 - Primary Circuit 2 - Domestic Hot Water Circuit 3 - Internal Electronic Part 4 - External Electronic Part 5 - Ignition and Detection 6 - Air inlet - flue gas outlet 7 - Multizone Malfunction warning This warning is shown by the display in the following format: Warning 5P1 = 1st Ignit Failed the first figure indicating the operational assembly is followed by a P (warning) and the code relating to the specific warning. ALERT Send Probe Damaged Table summarising error codes Safety shut-off due to insufficient water pressure If the water pressure inside the heating circuit is insufficient, the boiler will perform a safety shut-off . The error code “Fault 108 - Filling Needed” appears on the display The system may be restarted, re-balancing the value, by using the filling valve. ALERT Call the technical service Fault 108 Filling Needed Check the pressure on the pressure gauge and close the valve as soon as it reaches 1 - 1.5 bar. If the re-balancing request is performed on a frequent basis, switch the boiler off, bring the external electric switch to the OFF position, shut off the gas valve and contact a qualified technician to check for any leaks of water. Operation shutdown This type of error is “non-volatile”, which means that it is not removed automatically. The display will visualise the error code and description. “Fault 501 - No flame detected - Press the Reset button” In this case the boiler does not restart automatically, but it may be reset by pressing the button. ALERT Fault 501 No flame detected Press the Reset button Central Heating circuit Display Description 101 Overheat 102 Pressure Sens Error 103 104 105 Insufficient circulation 106 107 108 Insufficient water (request filling) 110 C.H. Flow temp. probe circuit open / short circuit 112 C.H. Return temp. probe circuit open / short circuit 114 External sensor circuit open / short circuit 116 Floor Thermostat contact open 118 Heating delevery probe problem 1P1 1P2 Insufficient circulation indication 1P3 1P4 Insufficient water (request filling) D.H.W. circuit 203 Tank Probe Damaged 205 DHW In Probe Open Circuit 209 Tank Overheat Internal P.C.B.’s 301 EEPROM error 302 Comunication error 303 Main P.C.B. error 304 Too many (> 5) resets in 15 minutes 305 Main P.C.B. error 306 Main P.C.B. error 307 Main P.C.B. error 3P9 Sched.Maintanace-Call Service Reset in progress Fault solved 29
Loading...
Loading...
commissioning AUTO function This is a function which enables the boiler to automatically adapt its operation routine (the temperature of the heating elements) in line with the outdoor conditions, in order to achieve and maintain the requested room temperature conditions. Depending on the peripheral units connected and the number of zones controlled, the boiler adjusts its flow temperature automatically. The various corresponding parameters should therefore be set (see Technical Area). To activate the function, press the AUTO button. For further information please refer to the ARISTON temperature adjustment manual. 24/01/2012 15:38 auto 44°C 38°C EXAMPLE 1: SINGLE ZONE SYSTEM (HIGH-TEMPERATURE) WITH ON/OFF ROOM THERMOSTAT: In this case the following parameters must be set: 4.2.1 - Activation of temperature adjustment using sensors - Select 04 = Basic temperature adjustment 2.4.4 - Boost Time (optional) The wait time for the flow temperature increase in steps of 4°C may be set. The value varies according to the type of system and installation. If the Boost Time value = 00 the function is not activated. EXAMPLE 2: SINGLE ZONE SYSTEM (HIGH-TEMPERATURE) WITH ON/OFF ROOM THERMOSTAT + OUTDOOR SENSOR: In this case the following parameters must be set: 4.2.1 - Activation of temperature adjustment using sensors - Select 01 = outdoor sensor only 4.2.2 - Temperature adjustment curve selection - Select the relevant curve according to the type of system, installation, heat insulation used in the building, etc. 4.2.3 - Perform a parallel curve shift if necessary, increasing or decreasing the set-point temperature (this may also be modified by the user, using the heating temperature adjustment knob, which, with the AUTO function activated, is used to shift the curve in a parallel manner). EXAMPLE 3: SINGLE ZONE SYSTEM (HIGH-TEMPERATURE) WITH SENSYS REMOTE CONTROL + OUTDOOR SENSOR In this case the following parameters must be set: 4.2.1 - Activation of temperature adjustment using sensors - select 0 = outdoor sensor + room sensor 4.2.2 - Temperature adjustment curve selection - Select the relevant curve according to the type of system, installation, heat insulation used in the building, etc 4.2.3 - Perform a parallel curve shift if necessary, increasing or decreasing the set-point temperature. (This may also be changed by the user by the encoder which, with the AUTO function activated, is used to shift the curve in a parallel manner.) 4.2.4 - Influence of room sensor - used to adjust the influence the room temperature has on the calculation of the set-point flow temperature (20 = maximum, 0 = minimum). 28
oiler protection devices The boiler is protected from malfunctions by means of internal checks performed by the electronic P.C.B., which stops the boiler from operating if necessary. In the event of the boiler being shut off in this manner, a code appears on the control panel display which refers to the type of shut-off and the reason behind it. Two types of shut-off may occur: Safety shut-off This type of error is “volatile”, which means that the boiler starts up again automatically as soon as the problem which caused the shutoff is removed. The display will visualise the error code and description. “Fault 110 - Send Probe Damaged” In fact, soon as the cause of the shut-off disappears, the boiler starts up again and continues to operate normally. If the boiler still indicates a safety shut-off, switch it off. Make sure the external electric switch is in the OFF position, shut off the gas valve and contact a qualified technician. Fault 110 Important If this shutdown occurs frequently, contact an authorised Technical Service Centre for assistance. For safety reasons, the boiler will permit a maximum of 5 resets in 15 minutes (5 presses of the RESET button); at the 6th attempt within this 15-minute period the boiler will shut down and may only be operated again after the electricity supply has been disconnected. If the shutdown is occasional or an isolated event, this is not a problem. The first figure of the error code (e.g. Errore 101) indicates within which operational assembly the error occurred. 1 - Primary Circuit 2 - Domestic Hot Water Circuit 3 - Internal Electronic Part 4 - External Electronic Part 5 - Ignition and Detection 6 - Air inlet - flue gas outlet 7 - Multizone Malfunction warning This warning is shown by the display in the following format: Warning 5P1 = 1st Ignit Failed the first figure indicating the operational assembly is followed by a P (warning) and the code relating to the specific warning. ALERT Send Probe Damaged Table summarising error codes Safety shut-off due to insufficient water pressure If the water pressure inside the heating circuit is insufficient, the boiler will perform a safety shut-off . The error code “Fault 108 - Filling Needed” appears on the display The system may be restarted, re-balancing the value, by using the filling valve. ALERT Call the technical service Fault 108 Filling Needed Check the pressure on the pressure gauge and close the valve as soon as it reaches 1 - 1.5 bar. If the re-balancing request is performed on a frequent basis, switch the boiler off, bring the external electric switch to the OFF position, shut off the gas valve and contact a qualified technician to check for any leaks of water. Operation shutdown This type of error is “non-volatile”, which means that it is not removed automatically. The display will visualise the error code and description. “Fault 501 - No flame detected - Press the Reset button” In this case the boiler does not restart automatically, but it may be reset by pressing the button. ALERT Fault 501 No flame detected Press the Reset button Central Heating circuit Display Description 101 Overheat 102 Pressure Sens Error 103 104 105 Insufficient circulation 106 107 108 Insufficient water (request filling) 110 C.H. Flow temp. probe circuit open / short circuit 112 C.H. Return temp. probe circuit open / short circuit 114 External sensor circuit open / short circuit 116 Floor Thermostat contact open 118 Heating delevery probe problem 1P1 1P2 Insufficient circulation indication 1P3 1P4 Insufficient water (request filling) D.H.W. circuit 203 Tank Probe Damaged 205 DHW In Probe Open Circuit 209 Tank Overheat Internal P.C.B.’s 301 EEPROM error 302 Comunication error 303 Main P.C.B. error 304 Too many (> 5) resets in 15 minutes 305 Main P.C.B. error 306 Main P.C.B. error 307 Main P.C.B. error 3P9 Sched.Maintanace-Call Service Reset in progress Fault solved 29
Loading...
Loading...
X