1 1 installation Electrical diagram For increased safety, ask a qualified technician to perform a thorough check of the electrical system. The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply. GENUS PREMIUM EVOHP 45/65 Peripheral unit T B BUS TA2 SE TNK SOL TA1 CN1 CN19 N L 1 LV connections CN14 CN13 CN6 CN8 1 1 1 CN9 FLAME N L 1 HV connections CN11 HV connection Gr Detection electrode CN19 FLAME N N L L LV connection Fan Ignitor Display C.H. Return temp. probe C.H. Flow temp. probe Flue thermostat Bl Bl Rd Rd Br Br 1 1 CN14 CN3 CN9 1 1 CN2 1 CN11 Wh Rd Bk Bk Br Bk Bk Bk Bk Bl Gas valve Diverter valve 1 CN25 1 Minimum water pressure switch Bk Br CN8 Circulation Pump 20
1 1 1 installation GENUS PREMIUM EVO HP 85/100 Peripheral unit T B BUS TA2 SE TNK SOL TA1 CN1 CN19 N L 1 LV connections CN14 CN13 CN6 CN8 1 1 1 CN9 FLAME N L 1 HV connections CN11 HV connection Gr Detection electrode CN19 FLAME N N L L LV connection Fan Display C.H. Return temp. probe C.H. Flow temp. probe Bl Bl Rd Rd 1 1 CN14 CN3 1 1 CN2 CN11 Wh Rd Bk Bk Br Bl Ignitor Gas valve Fume thermostat Thermal fuse Minimum water pressure switch Br Br Or Or Bk Bl Rd Wh Bk Bl CN9 CN25 1 1 CN8 CN6 1 CN11 CN18 Bk Bk Bk Bk Diverter valve Modulating Circulation Pump KIT Circulation Pump Two speed KIT 21
Loading...
Loading...
1 1 installation Electrical diagram For increased safety, ask a qualified technician to perform a thorough check of the electrical system. The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply. GENUS PREMIUM EVOHP 45/65 Peripheral unit T B BUS TA2 SE TNK SOL TA1 CN1 CN19 N L 1 LV connections CN14 CN13 CN6 CN8 1 1 1 CN9 FLAME N L 1 HV connections CN11 HV connection Gr Detection electrode CN19 FLAME N N L L LV connection Fan Ignitor Display C.H. Return temp. probe C.H. Flow temp. probe Flue thermostat Bl Bl Rd Rd Br Br 1 1 CN14 CN3 CN9 1 1 CN2 1 CN11 Wh Rd Bk Bk Br Bk Bk Bk Bk Bl Gas valve Diverter valve 1 CN25 1 Minimum water pressure switch Bk Br CN8 Circulation Pump 20
1 1 1 installation GENUS PREMIUM EVO HP 85/100 Peripheral unit T B BUS TA2 SE TNK SOL TA1 CN1 CN19 N L 1 LV connections CN14 CN13 CN6 CN8 1 1 1 CN9 FLAME N L 1 HV connections CN11 HV connection Gr Detection electrode CN19 FLAME N N L L LV connection Fan Display C.H. Return temp. probe C.H. Flow temp. probe Bl Bl Rd Rd 1 1 CN14 CN3 1 1 CN2 CN11 Wh Rd Bk Bk Br Bl Ignitor Gas valve Fume thermostat Thermal fuse Minimum water pressure switch Br Br Or Or Bk Bl Rd Wh Bk Bl CN9 CN25 1 1 CN8 CN6 1 CN11 CN18 Bk Bk Bk Bk Diverter valve Modulating Circulation Pump KIT Circulation Pump Two speed KIT 21
Loading...
Loading...