Views
2 years ago

Genus EVO HP - Manual

  • Text
  • Wwwaristoncom
  • Sensor
  • Installation
  • Parameter
  • Premium
  • Flue
  • Genus
  • Appliance
  • Heating
  • Boiler

INDEX Overview

INDEX Overview ..................................................................................................................3 Advice for the installer ..........................................................................................3 CE labelling ...............................................................................................................3 Safety regulations ..................................................................................................4 Product description ............................................................................................5 Control Panel............................................................................................................5 Display ........................................................................................................................5 Overall wiew 45/65 ................................................................................................6 Overall wiew 85/100..............................................................................................6 Overall wiew 115/150 ...........................................................................................7 Overall dimension 45/65 .....................................................................................8 Overall dimension 85/100 ...................................................................................8 Overall dimension 115/150 ................................................................................9 Technical Information 45/65/85/100 ............................................................ 10 Technical Information 115/150 ...................................................................... 11 Boiler protection devices .............................................................................. 29 Safety shut-off ...................................................................................................... 29 Shutdown ............................................................................................................... 29 Table summarising error codes ...................................................................... 29 Anti-freeze function ........................................................................................... 30 Thechnical area .................................................................................................. 31 Maintenance ........................................................................................................ 38 Instruction for opening the casing and performing an internal inspection ..................................................................................... 38 General comments ............................................................................................. 39 Information for the user .................................................................................... 39 Data Plate Symbol ............................................................................................... 40 Installation ........................................................................................................... 12 Before installing the appliance ....................................................................... 12 Minimum clearances ......................................................................................... 12 Gas Connection .................................................................................................... 13 Water connection ................................................................................................ 13 View of the boiler connections....................................................................... 13 Residual Head of the boiler ............................................................................. 14 Excessive pressure device ................................................................................ 14 Cleaning the heating system .......................................................................... 14 Appliances with underfloor heating ............................................................ 15 Indirect cylinder connection ........................................................................... 15 System water characteristics ........................................................................... 15 Discharge of condensation .............................................................................. 15 Water circuit diagram......................................................................................... 16 Connecting the flue ............................................................................................ 17 Types of boiler - flue exhaust connection .................................................. 17 Table of flue gas exhaust duct lengths ........................................................ 18 Type of air suction/flue gas exhaust ducting ............................................ 18 Electrical connection.......................................................................................... 19 Peripheral unit connection .............................................................................. 19 Electrical diagram 45/65 ................................................................................... 20 Electrical diagram 85/100 ................................................................................. 21 Electrical diagram 115/150 .............................................................................. 22 Commissioning .................................................................................................. 23 Start-up procedure ............................................................................................. 23 Ignition procedure .............................................................................................. 23 Initial procedures ................................................................................................. 23 Electricity supply ................................................................................................. 23 Filling the hydraulic circuit ............................................................................... 23 Gas supply .............................................................................................................. 23 First Ignition .......................................................................................................... 24 Dearation cycle .................................................................................................... 24 Cleaning function and combustion analysis ............................................. 25 Checking the gas setting .................................................................................. 25 Maximum gas flow combustion analysis .................................................... 25 Minimum gas flow combustion analysis .................................................... 25 Adjustment the Maximum Heating power ................................................ 26 Soft Light adjustment ........................................................................................ 27 Ignition Delay adjustment ............................................................................... 27 Table summarising changes ............................................................................ 27 Gas changeover ................................................................................................... 27 AUTO function ...................................................................................................... 28

overview Advice for the installer The installation and first ignition of the boiler must be performed by qualified personnel in compliance with current national regulations regarding installation, and in conformity with any requirements established by local authorities and public health organisations. After the boiler has been installed, the installer must ensure that the end user receives the declaration of conformity and the operating manual, and should provide all necessary information as to how the boiler and the safety devices should be handled. CE labelling The CE mark guarantees that the appliance conforms to the following directives: - 2009/142/CE relating to gas appliances - 2004/108/CEE relating to electromagnetic compatibility - 92/42/CEE relating to energy efficiency - 2006/95/CEE relating to electrical safety This appliance is designed to produce hot water for domestic use. It should be connected to a heating system and a distribution network for domestic hot water, both of which must be compatible with its performance and power levels. Genus Premium EVO HP is designed to work individually or in cascade (max 8 devices - see Instructions manual for Cascade). The use of the appliance for purposes other than those specified is strictly forbidden. The manufacturer cannot be held responsible for any damage caused by improper, incorrect and unreasonable use of the appliance or by the failure to comply with the instructions given in this manual. Installation, maintenance and all other interventions must be carried out in full conformity with the governing legal regulations and the instructions provided by the manufacturer. Incorrect installation can harm persons, animals and possessions; the manufacturing company shall not be held responsible for any damage caused as a result. The boiler is delivered in a carton. Once you have removed all the packaging, make sure the appliance is intact and that no parts are missing. If this is not the case, please contact your supplier. Keep all packaging material (clips, plastic bags, polystyrene foam, etc.) out of reach of children as it may present a potential hazard. In the event of a fault and/or malfunction, turn the appliance off, turn off the gas cock and do not attempt to repair it yourself. Contact a qualified professional instead. Before any maintenance or repair work is performed on the boiler, make sure you have disconnected it from the electricity supply by switching the external bipolar switch to the “OFF” position. All repairs, which should only be performed using original spare parts, should be carried out by a qualified professional. Failure to comply with the above instructions could compromise the safety of the appliance and invalidate all liability on the part of the manufacturer. In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories, switch the appliance off by switching the external bipolar switch to the “OFF” position and shutting off the gas valve. When the work has been completed, ask a qualified technician to check the efficiency of the ducting and the devices. Turn the boiler off and turn the external switch “OFF” to clean the exterior parts of the appliance. Clean using a cloth dampened with soapy water. Do not use aggressive detergents, insecticides or toxic products. If the appliance is used in full compliance with current legislation, it will operate in a safe, environmentally-friendly and cost-efficient manner. If using kits or optional extras, make sure they are authentic. 3

MANUALS

Views
2 years ago

Genus EVO HP - Manual

  • Text
  • Wwwaristoncom
  • Sensor
  • Installation
  • Parameter
  • Premium
  • Flue
  • Genus
  • Appliance
  • Heating
  • Boiler

INDEX Overview

INDEX Overview ..................................................................................................................3 Advice for the installer ..........................................................................................3 CE labelling ...............................................................................................................3 Safety regulations ..................................................................................................4 Product description ............................................................................................5 Control Panel............................................................................................................5 Display ........................................................................................................................5 Overall wiew 45/65 ................................................................................................6 Overall wiew 85/100..............................................................................................6 Overall wiew 115/150 ...........................................................................................7 Overall dimension 45/65 .....................................................................................8 Overall dimension 85/100 ...................................................................................8 Overall dimension 115/150 ................................................................................9 Technical Information 45/65/85/100 ............................................................ 10 Technical Information 115/150 ...................................................................... 11 Boiler protection devices .............................................................................. 29 Safety shut-off ...................................................................................................... 29 Shutdown ............................................................................................................... 29 Table summarising error codes ...................................................................... 29 Anti-freeze function ........................................................................................... 30 Thechnical area .................................................................................................. 31 Maintenance ........................................................................................................ 38 Instruction for opening the casing and performing an internal inspection ..................................................................................... 38 General comments ............................................................................................. 39 Information for the user .................................................................................... 39 Data Plate Symbol ............................................................................................... 40 Installation ........................................................................................................... 12 Before installing the appliance ....................................................................... 12 Minimum clearances ......................................................................................... 12 Gas Connection .................................................................................................... 13 Water connection ................................................................................................ 13 View of the boiler connections....................................................................... 13 Residual Head of the boiler ............................................................................. 14 Excessive pressure device ................................................................................ 14 Cleaning the heating system .......................................................................... 14 Appliances with underfloor heating ............................................................ 15 Indirect cylinder connection ........................................................................... 15 System water characteristics ........................................................................... 15 Discharge of condensation .............................................................................. 15 Water circuit diagram......................................................................................... 16 Connecting the flue ............................................................................................ 17 Types of boiler - flue exhaust connection .................................................. 17 Table of flue gas exhaust duct lengths ........................................................ 18 Type of air suction/flue gas exhaust ducting ............................................ 18 Electrical connection.......................................................................................... 19 Peripheral unit connection .............................................................................. 19 Electrical diagram 45/65 ................................................................................... 20 Electrical diagram 85/100 ................................................................................. 21 Electrical diagram 115/150 .............................................................................. 22 Commissioning .................................................................................................. 23 Start-up procedure ............................................................................................. 23 Ignition procedure .............................................................................................. 23 Initial procedures ................................................................................................. 23 Electricity supply ................................................................................................. 23 Filling the hydraulic circuit ............................................................................... 23 Gas supply .............................................................................................................. 23 First Ignition .......................................................................................................... 24 Dearation cycle .................................................................................................... 24 Cleaning function and combustion analysis ............................................. 25 Checking the gas setting .................................................................................. 25 Maximum gas flow combustion analysis .................................................... 25 Minimum gas flow combustion analysis .................................................... 25 Adjustment the Maximum Heating power ................................................ 26 Soft Light adjustment ........................................................................................ 27 Ignition Delay adjustment ............................................................................... 27 Table summarising changes ............................................................................ 27 Gas changeover ................................................................................................... 27 AUTO function ...................................................................................................... 28

overview Advice for the installer The installation and first ignition of the boiler must be performed by qualified personnel in compliance with current national regulations regarding installation, and in conformity with any requirements established by local authorities and public health organisations. After the boiler has been installed, the installer must ensure that the end user receives the declaration of conformity and the operating manual, and should provide all necessary information as to how the boiler and the safety devices should be handled. CE labelling The CE mark guarantees that the appliance conforms to the following directives: - 2009/142/CE relating to gas appliances - 2004/108/CEE relating to electromagnetic compatibility - 92/42/CEE relating to energy efficiency - 2006/95/CEE relating to electrical safety This appliance is designed to produce hot water for domestic use. It should be connected to a heating system and a distribution network for domestic hot water, both of which must be compatible with its performance and power levels. Genus Premium EVO HP is designed to work individually or in cascade (max 8 devices - see Instructions manual for Cascade). The use of the appliance for purposes other than those specified is strictly forbidden. The manufacturer cannot be held responsible for any damage caused by improper, incorrect and unreasonable use of the appliance or by the failure to comply with the instructions given in this manual. Installation, maintenance and all other interventions must be carried out in full conformity with the governing legal regulations and the instructions provided by the manufacturer. Incorrect installation can harm persons, animals and possessions; the manufacturing company shall not be held responsible for any damage caused as a result. The boiler is delivered in a carton. Once you have removed all the packaging, make sure the appliance is intact and that no parts are missing. If this is not the case, please contact your supplier. Keep all packaging material (clips, plastic bags, polystyrene foam, etc.) out of reach of children as it may present a potential hazard. In the event of a fault and/or malfunction, turn the appliance off, turn off the gas cock and do not attempt to repair it yourself. Contact a qualified professional instead. Before any maintenance or repair work is performed on the boiler, make sure you have disconnected it from the electricity supply by switching the external bipolar switch to the “OFF” position. All repairs, which should only be performed using original spare parts, should be carried out by a qualified professional. Failure to comply with the above instructions could compromise the safety of the appliance and invalidate all liability on the part of the manufacturer. In the event of any maintenance or other structural work in the immediate vicinity of the ducts or flue gas exhaust devices and their accessories, switch the appliance off by switching the external bipolar switch to the “OFF” position and shutting off the gas valve. When the work has been completed, ask a qualified technician to check the efficiency of the ducting and the devices. Turn the boiler off and turn the external switch “OFF” to clean the exterior parts of the appliance. Clean using a cloth dampened with soapy water. Do not use aggressive detergents, insecticides or toxic products. If the appliance is used in full compliance with current legislation, it will operate in a safe, environmentally-friendly and cost-efficient manner. If using kits or optional extras, make sure they are authentic. 3