installation The installation and first ignition of the boiler must be performed by qualified personnel in compliance with current national regulations regarding installation, and in conformity with any requirements established by local authorities and public health organisations. Minimum clearances In order to allow easy access for boiler maintenance operations, installation distance must be suitable. Position the boiler according to the established technical rules, using a spirit level. Genus Premium EVO HP is designed to work individually or in cascade (max 8 devices). Is necessary that all requirements are met by the rules and regulations for equipment equivalent to the total installed power generators. In particular, the local installation, security devices and flue exhausts evacuation system should be adjusted to the total potential of the cascade. The requirements for installation in this manual concerning the installation of a single device. To install the cascade read the installation manual included in Kit. GENUS PREMIUM EVO HP 45/65 350 50 50 Before installing the appliance The boiler heats water to a temperature below boiling. It should be connected to a heating system and to a domestic water mains supply, both of which must correspond in size to the performance and its power of the appliance. Before connecting the boiler, it is first necessary to perform the following operations: - Carefully wash the system piping in order to remove any screw thread or welding residues, or any dirt which might prevent the boiler from operating correctly. - Make sure that the boiler is set up for operation with the type of gas available (read the information on the packaging label and on the boiler data plate). - Make sure that there are no obstacles inside flue exhaust and that it does not contain any discharge from other appliances, unless the flue is meant to serve more than one user (in accordance with current legal requirements). - Where there is already a connection to existing flue exhausts, check that these exhausts have been perfectly cleaned and are without residues, because any disconnection could obstruct the passage of fumes and create potentially dangerous situations. - Make sure that, where unsuitable flue exhausts are attached, they have been ducted. - In areas with particularly hard water, limescale may build up on the components inside the boiler and reduce its overall efficiency. C-type boilers, with combustion chambers and air supply circuits which are completely sealed from the air outside, do not have any limitations concerning the ventilation and size of the room in which they are installed. So that the normal operation of the boiler is not compromised, the place in which it is installed must be suitable with regard to the operating limit temperature value and the appliance should be protected so that it does not come into direct contact with atmospheric agents. 450 GENUS PREMIUM EVO HP 85/100/115/150 450 350 30 0 50 50 400 WARNING No inflammable items should be left in the vicinity of the boiler. Make sure the installation site and any systems to which the appliance must be connected are fully compliant with the current applicable legislation. If dust and/or aggressive vapours are present in the room in which it is to be installed, the appliance must operate independently of the air inside the room. 12
installation Gas connection The boiler was designed to use gases belonging to the categories as shown in the following table. COUNTRY MODEL CATEGORIES GENUS PREMIUM EVO HP 45 GENUS PREMIUM EVO HP 65 GENUS PREMIUM EVO HP 85 GENUS PREMIUM EVO HP 100 GENUS PREMIUM EVO HP 115 GENUS PREMIUM EVO HP 150 Make sure, using the labels on the packaging and the data plate on the appliance itself, that the boiler is in the correct country and that the gas category for which the boiler was designed corresponds to one of the categories available in the country where it will be used. The gas supply piping must be created and measured out in compliance with specific legal requirements and in accordance with the maximum power of the boiler; you should also make sure that the shut-off valve is the right size and that it is connected correctly. Before carrying out the installation, it is recommended that the fuel pipes are cleaned thoroughly in order to remove any residues which could prevent the boiler from operating correctly. Check that the supplied gas corresponds to the type of gas for which the boiler was designed (see the data plate located on the appliance itself). It is also important to check that the pressure of the gas (methane or LPG) you will be using to feed the boiler is suitable, because if it is insufficient the power of the generator may be reduced, causing inconvenience for the user. Water connection The illustration shows the connections for the water and gas attachments of the boiler. View of the Boiler Connections A. Central heating Flow 1” M C. Gas Inlet 3/4”M E. Central Heating Return 1” M F. Drain condensate GENUS PREMIUM EVOHP 45/65 A C E F GENUS PREMIUM EVO HP 85/100 A F C E A. Central heating Flow 1” ¼ M C. Gas Inlet 1” M E. Central Heating Return 1” ¼ M G. Drain condensate GENUS PREMIUM EVO HP 115/150 A F C E A. Central heating Flow 1” 1/2 M C. Gas Inlet 1” M E. Central Heating Return 1” 1/2 M G. Drain condensate 13
Loading...
Loading...
installation The installation and first ignition of the boiler must be performed by qualified personnel in compliance with current national regulations regarding installation, and in conformity with any requirements established by local authorities and public health organisations. Minimum clearances In order to allow easy access for boiler maintenance operations, installation distance must be suitable. Position the boiler according to the established technical rules, using a spirit level. Genus Premium EVO HP is designed to work individually or in cascade (max 8 devices). Is necessary that all requirements are met by the rules and regulations for equipment equivalent to the total installed power generators. In particular, the local installation, security devices and flue exhausts evacuation system should be adjusted to the total potential of the cascade. The requirements for installation in this manual concerning the installation of a single device. To install the cascade read the installation manual included in Kit. GENUS PREMIUM EVO HP 45/65 350 50 50 Before installing the appliance The boiler heats water to a temperature below boiling. It should be connected to a heating system and to a domestic water mains supply, both of which must correspond in size to the performance and its power of the appliance. Before connecting the boiler, it is first necessary to perform the following operations: - Carefully wash the system piping in order to remove any screw thread or welding residues, or any dirt which might prevent the boiler from operating correctly. - Make sure that the boiler is set up for operation with the type of gas available (read the information on the packaging label and on the boiler data plate). - Make sure that there are no obstacles inside flue exhaust and that it does not contain any discharge from other appliances, unless the flue is meant to serve more than one user (in accordance with current legal requirements). - Where there is already a connection to existing flue exhausts, check that these exhausts have been perfectly cleaned and are without residues, because any disconnection could obstruct the passage of fumes and create potentially dangerous situations. - Make sure that, where unsuitable flue exhausts are attached, they have been ducted. - In areas with particularly hard water, limescale may build up on the components inside the boiler and reduce its overall efficiency. C-type boilers, with combustion chambers and air supply circuits which are completely sealed from the air outside, do not have any limitations concerning the ventilation and size of the room in which they are installed. So that the normal operation of the boiler is not compromised, the place in which it is installed must be suitable with regard to the operating limit temperature value and the appliance should be protected so that it does not come into direct contact with atmospheric agents. 450 GENUS PREMIUM EVO HP 85/100/115/150 450 350 30 0 50 50 400 WARNING No inflammable items should be left in the vicinity of the boiler. Make sure the installation site and any systems to which the appliance must be connected are fully compliant with the current applicable legislation. If dust and/or aggressive vapours are present in the room in which it is to be installed, the appliance must operate independently of the air inside the room. 12
installation Gas connection The boiler was designed to use gases belonging to the categories as shown in the following table. COUNTRY MODEL CATEGORIES GENUS PREMIUM EVO HP 45 GENUS PREMIUM EVO HP 65 GENUS PREMIUM EVO HP 85 GENUS PREMIUM EVO HP 100 GENUS PREMIUM EVO HP 115 GENUS PREMIUM EVO HP 150 Make sure, using the labels on the packaging and the data plate on the appliance itself, that the boiler is in the correct country and that the gas category for which the boiler was designed corresponds to one of the categories available in the country where it will be used. The gas supply piping must be created and measured out in compliance with specific legal requirements and in accordance with the maximum power of the boiler; you should also make sure that the shut-off valve is the right size and that it is connected correctly. Before carrying out the installation, it is recommended that the fuel pipes are cleaned thoroughly in order to remove any residues which could prevent the boiler from operating correctly. Check that the supplied gas corresponds to the type of gas for which the boiler was designed (see the data plate located on the appliance itself). It is also important to check that the pressure of the gas (methane or LPG) you will be using to feed the boiler is suitable, because if it is insufficient the power of the generator may be reduced, causing inconvenience for the user. Water connection The illustration shows the connections for the water and gas attachments of the boiler. View of the Boiler Connections A. Central heating Flow 1” M C. Gas Inlet 3/4”M E. Central Heating Return 1” M F. Drain condensate GENUS PREMIUM EVOHP 45/65 A C E F GENUS PREMIUM EVO HP 85/100 A F C E A. Central heating Flow 1” ¼ M C. Gas Inlet 1” M E. Central Heating Return 1” ¼ M G. Drain condensate GENUS PREMIUM EVO HP 115/150 A F C E A. Central heating Flow 1” 1/2 M C. Gas Inlet 1” M E. Central Heating Return 1” 1/2 M G. Drain condensate 13
Loading...
Loading...
CATALOGUE
PRODUCT BROCHURES
DATASHEETS
MANUALS
MANUALS (DISCONTINUED)
PLANNER MANUALS
CASE STUDIES