Views
2 years ago

Eureka - Manual

  • Text
  • Water
  • Water heater
  • Wwwaristoncom
  • Electrical
  • Manual
  • Valve
  • Appliance
  • Heater
  • Spout
  • Eureka
  • Heating

GB Thank you for

GB Thank you for choosing this Eureka Open Outlet Water Heater. This Manual will provide you with all the information required to install and maintain your Eureka Open Outlet Water Heater and also provides suggestions which will help you to obtain the best performance from your appliance. The Eureka Open Outlet Water Heater is: SAFE All of its components are completely waterproof (IP 25D Certified). EASY TO USE Due to its ceramic disc mixer. ENVIRONMENTALLY FRIENDLY The appliance and all of its packaging is fully recyclable. RELIABLE AND DURABLE It is made with the highest quality materials and the tank is made of a special plastic. PLEASE ENSURE YOU READ THE GUARANTEE Legend (fig. 1) 1) Heating warning light 9) Waterpipe 2) Illuminated on/off switch 10) Waterpipe support 3) Water inlet connection 11) Electrical supply cable 4) Water outlet connection 12) Outlet spout 5) Cover 13) Safety valve 6) Lever for mixing valve 14) Nonreturn valve (only if supplied 7) Mounting Bracket with the appliance) 8) Integral fixing hook IMPORTANT INSTRUCTIONS The installation of the appliance is at the expense of the purchaser. The manufacturer declines any liability from damage caused by improper installation or failure to comply with the instructions contained in this manual. In particular you should ensure: 1. That the electrical and water connections are made with the instructions provided in this manual and also all relevant IEE and Water Bylaw regulations. 2. Only original spares are used. Location of the Eureka Open Outlet Water Heater The Eureka can be installed both indoors and outdoors and should be installed to the relevant Bylaws. 23

GB The Eureka has a degree of protection against penetration of liquids of IP 25 D and can be installed anywhere provided that: a) It is not installed in a bathtub or prefabricated shower cubical. b) It is connected by means of the cable to a protected socket with a differential circuit breaker placed at more than 1.2 m from the appliance. INSTALLATION INSTRUCTIONS 1. Wall Mounting (Fig. 2) a) Fix the support bracket (7) to the wall using the screws supplied as shown in fig. 2. b) Fit the hook on the back of the Eureka (8) into the guide of the bracket (7). c) Pull the Eureka downwards fully unit it fits correctly into place. 2. Water Connections (Fig. 3) WARNING - This appliance is of the Open Outlet type. Therefore only the spout and safety valve (13) (counter clockwise) supplied must be used. The outlet spout is used to dischare any expanded water, consequently no restrictive device must be connected to it. N.B. If the mains water pressure is over 3 bar then a suitable pressure reducing valve must be fitted. a) Connect mains water supply to inlet pipe (3) using pipe manufactured of a suitable material. (I.E. copper). b) Connect the spout to the outlet connection. 3. Electrical Connections a) Ensure that the mains voltage complies with the valve shown on the data badge of the appliance i.e. 230/240 volts. b) Connect via the cable supplied to a switched spur (dual pole 3 mm contacts fused at 13 amp) as follows: L - Brown N - Blue E - Green/Yellow N. B. If your Eureka has been supplied with a continental style moulded plug it must be removed. 4. Commissioning (Fig. 1) a) Turn on water supply to the appliance. 24

MANUALS

Views
2 years ago

Eureka - Manual

  • Text
  • Water
  • Water heater
  • Wwwaristoncom
  • Electrical
  • Manual
  • Valve
  • Appliance
  • Heater
  • Spout
  • Eureka
  • Heating

GB Thank you for

GB Thank you for choosing this Eureka Open Outlet Water Heater. This Manual will provide you with all the information required to install and maintain your Eureka Open Outlet Water Heater and also provides suggestions which will help you to obtain the best performance from your appliance. The Eureka Open Outlet Water Heater is: SAFE All of its components are completely waterproof (IP 25D Certified). EASY TO USE Due to its ceramic disc mixer. ENVIRONMENTALLY FRIENDLY The appliance and all of its packaging is fully recyclable. RELIABLE AND DURABLE It is made with the highest quality materials and the tank is made of a special plastic. PLEASE ENSURE YOU READ THE GUARANTEE Legend (fig. 1) 1) Heating warning light 9) Waterpipe 2) Illuminated on/off switch 10) Waterpipe support 3) Water inlet connection 11) Electrical supply cable 4) Water outlet connection 12) Outlet spout 5) Cover 13) Safety valve 6) Lever for mixing valve 14) Nonreturn valve (only if supplied 7) Mounting Bracket with the appliance) 8) Integral fixing hook IMPORTANT INSTRUCTIONS The installation of the appliance is at the expense of the purchaser. The manufacturer declines any liability from damage caused by improper installation or failure to comply with the instructions contained in this manual. In particular you should ensure: 1. That the electrical and water connections are made with the instructions provided in this manual and also all relevant IEE and Water Bylaw regulations. 2. Only original spares are used. Location of the Eureka Open Outlet Water Heater The Eureka can be installed both indoors and outdoors and should be installed to the relevant Bylaws. 23

GB The Eureka has a degree of protection against penetration of liquids of IP 25 D and can be installed anywhere provided that: a) It is not installed in a bathtub or prefabricated shower cubical. b) It is connected by means of the cable to a protected socket with a differential circuit breaker placed at more than 1.2 m from the appliance. INSTALLATION INSTRUCTIONS 1. Wall Mounting (Fig. 2) a) Fix the support bracket (7) to the wall using the screws supplied as shown in fig. 2. b) Fit the hook on the back of the Eureka (8) into the guide of the bracket (7). c) Pull the Eureka downwards fully unit it fits correctly into place. 2. Water Connections (Fig. 3) WARNING - This appliance is of the Open Outlet type. Therefore only the spout and safety valve (13) (counter clockwise) supplied must be used. The outlet spout is used to dischare any expanded water, consequently no restrictive device must be connected to it. N.B. If the mains water pressure is over 3 bar then a suitable pressure reducing valve must be fitted. a) Connect mains water supply to inlet pipe (3) using pipe manufactured of a suitable material. (I.E. copper). b) Connect the spout to the outlet connection. 3. Electrical Connections a) Ensure that the mains voltage complies with the valve shown on the data badge of the appliance i.e. 230/240 volts. b) Connect via the cable supplied to a switched spur (dual pole 3 mm contacts fused at 13 amp) as follows: L - Brown N - Blue E - Green/Yellow N. B. If your Eureka has been supplied with a continental style moulded plug it must be removed. 4. Commissioning (Fig. 1) a) Turn on water supply to the appliance. 24