SETTINGS - ADJUSTMENT -

SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS Accessing the settings - adjustment - problem identification menus The boiler can be used to manage the heating and domestic hot water production system in its entirety. Navigation within the menus enables the boiler system + connected peripheral units to be customised, optimising operation for maximum comfort and maximum saving. It also provides important information relating to the efficient operation of the boiler. Before access to the menus, the display show some “quick settings” to have direct access to the parameters. To see all available parameters and menu access to view FULL MENU. GAS - Direct access to the parameters: 220 - 231- 232- 233 - 234 - 270 SET - Direct access to the parameters: 220 - 231- 223 - 245 - 246 PCB - Direct access to the parameters: 220 - 228 - 229 - 231- 232- 233 - 234 - 247 - 250 - 253 VIS - Direct access to the parameters: 821 - 822 - 824 - 825 - 827 - 830 - 831 - 832 - 833- 840 - 835 ZONE - Direct access to the parameters: 402 - 502 - 602 - 420 - 520 - 620 -434 - 534 - 634 - 830 FULL MENU - see table on following pages 0 NETWORK 0 4 User Interface 2 Boiler Parameter 2 0 General setting 2 2 Boiler parameter 2 2 General setting 2 3 C.H. Parameters - Part 1 2 4 C.H. Parameters - Part 2 2 5 Domestic Hot Water 2 6 Boiler manual settings 2 7 Test & Utilities 2 8 Menù 2 Reset to factory setting 4 Zone 1 Parameters 4 0 Set-point Zone1 4 2 Zone 1 Setting 4 3 Diagnostics 5 Parametri Zona 2 5 0 Set-point Zone2 5 2 Zone 2 Setting 5 3 Diagnostics 6 Parametri Zona 3 6 0 Set-point Zone3 6 2 Zone 3 Setting 6 3 Diagnostics 8 Service Parameter 8 0 Statistics-1 8 1 Statistics-2 8 2 Boiler 8 3 Boiler Temperature 8 4 Solar & Storage 8 5 Service 8 6 Error History 8 7 Free parameter The parameters relating to each individual menu are listed in the following pages. The various parameters can be accessed and modified using the “+” and“-” , “+” OK and “-” buttons. (see fig. below). The description of the menus and of each individual parameter will be shown on the display. 2 8 2. “+” and “-” buttons to access and modify the parameters. 8. “+” OK button to store the adjustments of various parameters. “-” (ESC) button to exit from the parameters. The menus and parameters number is shown by the figures of the display. CAUTION! THE MENUS RESERVED FOR QUALIFIED TECHNICIANS MAY ONLY BE ACCESSED AFTER SETTING THE ACCESS CODE. To access the Menus, open the cover and proceed as follows (for example: 231 1. Simultaneously press the 2 “+” and “-” buttons for 5 seconds. Insert the service code, the display shows 222 2. Press the “+” button to select 234. 3. Press the “+” OK button. the display shows the first “quick setting” GAS 4. Press the “+” button to select MENU (Complete MENU) 3. Press the “+” OK button.The display shows menu 0 4. Press the “+” button to select menu 2. 5. Press the “+” OK button to access to the menu. The display shows the sub-menu 20. 4. Press the “+” button to select the sub-menu 23. 3. Press the “+” OK button to access to the submenu. The display shows the parameter 230. 4. Press the “+” button to select the parameter 231. 5. Press the “+” OK button to access to the parameter. The display shows the value “ex: 70” . 6. Press the 2 “+” or “-” button to select the new value “ex: 75” 7. Press the “+” OK button pto save the change or press “-” (ESC) button to exit without saving. Press the “-” (ESC) button until the normal display screen is restored. 40 /

SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS menu sub-menu Parameter Description value default setting SERVICE CODE 0 NETWORK Press the button “+” 0 4 DISPLAY SETTING to select code 234 and press Ok. Turn the encoder to select MENU and press OK button 0 4 0 Zone to be set by display 1 = 1 Zone 1 2 = 2 Zone 3 = 3 Zone 0 4 1 Backlight timing from 0 to 10 (minutes) or 24 24 (hour) 0 4 2 Thermoregulation button deactivation 0 = OFF 0 1 = ON 2 BOILER PARAMETER SETTING 2 0 GENERAL 2 0 0 DHW Setpoint Temperature from 36 to 60 (°C) Setting by DHW button 2 2 0 1 DHW Pre-heating 0 = OFF 1 = ON RESERVED FOR TECHNICAL ASSISTANCE Only if the PCB is changed 2 1 BOILER PARAMETERS 2 0 0 Boiler circulator type (NOT ACTIVE) 2 2 BOILER GENERAL SETTINGS 2 2 0 Soft ignition from 0 to 90 60 See parag. Gas settings 2 2 3 Underfloor thermostat or zone 2 ambient 0 = Floor safety thermostat 0 thermostat selection 1 = Zone 2 ambient thermostat 2 2 4 Thermoregulation 0 = Absent 0 1 = Present 2 2 5 Heating ignition delay 0 = Deactivated 1 = 10 seconds 2 = 90 seconds 3 = 210 seconds 0 2 2 8 Boiler Version - E-COMBI ONE CANNOT BE MODIFIED Boiler Version - E-SYSTEM ONE CANNOT BE MODIFIED 2 2 9 Set boiler heat power from 0 to 5 0 from 0 to 5 2 RESERVED FOR TECHNICAL ASSISTANCE Only if the PCB is changed 2 3 BOILER PARAMETER - PART 1 2 3 1 Maximum heating power setting from 0 to 99 60 see the “Gas setting” table, information on Starting 2 3 2 Domestic hot water maximum percentage CANNOT BE MODIFIED from 0 to 99 2 3 3 Minimum percentage CANNOT BE MODIFIED 2 3 4 Heating maximum percentage CANNOT BE MODIFIED 2 3 5 Selection of ignition delay type when heating from 0 to 99 from 0 to 99 0 = Manual 1 = Automatic 2 3 6 Ignition delay when heating timer setting from 0 to 7 (minutes) 3 2 3 7 Post-circulation when heating from 0 to 15 minutes or OC (AC) 3 2 3 8 2 3 9 1 RESERVED FOR TECHNICAL ASSISTANCE Only if the gas or PCB is changed see “gas setting” table / 41

MANUALS