Views
3 years ago

E-Combi ONE - Installation Manual

  • Text
  • Boiler
  • Heating
  • Flue
  • Appliance
  • Efficiency
  • Valve
  • Installation
  • Parameter
  • Maintenance
  • Domestic
  • Install

INSTALLATION Table of

INSTALLATION Table of flue gas exhaust duct lengths FLUE TYPE Coaxial System Twin-pipe System Maximum Extension Exhaust-air (m) E-COMBI ONE E-SYSTEM ONE 24 30 24 30 Diameter of pipe (mm) C13 C33 8 7 8 7 ø 60/100 C43 C13 C33 C43 33 24 33 24 ø 80/125 S1 = S2 C13 24/24 26/26 24/24 26/26 C33 48/48 40/40 40/40 32/32 ø 80/80 C43 24/24 26/26 24/24 26/26 C53 S1 + S2 S1 + S2 60 50 60 50 ø 80/80 S1 = Air intake S2 = Flue gas exhaust S1 = S2 - Air intake and flue gas exhaust equal lengths S1 + S2 - Air intake and flue gas exhaust unequal lengths TYPE C13 TYPE C33 TYPE C33 TYPE C33 TYPE C53 24 /

OK T B BUS 1 2 3 4 5 6 7 INSTALLATION WARNING! BEFORE PERFORMING ANY WORK ON THE BOILER, FIRST DISCONNECT IT FROM THE ELECTRICAL POWER SUPPLY USING THE EXTERNAL BIPOLAR SWITCH AND REMOVE THE FUSE. Peripheral unit connection To access peripheral unit connections carry out the following steps: - Disconnect the boiler from the power supply - Remove the casing - Rotate the control panel while pulling it forwards - Unhook the two clips to have access to the peripherical connections and the main P.C.B. Electrical connections For increased safety, ask a qualified technician to perform a thorough check of the electrical system. The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply. Make sure that the system is able to withstand the maximum power absorbed by the boiler (this is indicated on the appliance data plate). Check that the section of the wires is suitable and is not less 0,75 mm 2 The appliance must be connected to an effiecient earthing system if it is to operate correctly. The power supply cable must be connected to a 230V-50Hz network, where the L-N poles and the earth connection are all respected. Important! In the event that the power supply cable must be changed, replace it with one with the same specifications. Power supply cable 60 mm TA2 SE TNK SOL TA1 N L H05V2V2-F Important! The appliance is supplied with a fly-lead already connected, this must be connected to a 240V supply fused at 3 Amp and must facilitate completed electrical isolation of the appliance, by use of a fused double pole isolator having a contact separation of at least 3mm in all poles or alternatively by means of a 3A fused three pin plug and unswitched shuttered socket outlet both complying with BS1363. The use of multiplugs, extension leads or adaptors is strictly prohibited. It is strictly forbidden to use the piping from the hydraulic, heating and gas systems for the appliance earthing connection. The boiler is not protected against the effects caused by lightning. If the mains fuses need to be replaced, use 2A rapid fuses. Peripheral connections: BUS = Remote control connection FLOOR/TA2 = the underfloor heating thermostat or the room thermostat 2 (selected via parameter 223) SE = the external sensor. SOL = Solar temperature probe TA1 = the room thermostat 1 SENSYS Remote Control (option) Outdoor Sensor Room Thermostat1 (option) T B FLOOR BUS TA2 SE TNK SOL TA1 CN1 / 25

MANUALS