GB6. TURBO/SELF CLEAN

GB6. TURBO/SELF CLEAN BUTTONTURBOPress to select the fan speed: normal (the “ ” indicator light turns on) or turbo (the “ ” indicator light turns on).NOTE: the TURBO button is disabled in SUPER LAUNDRY ROOM mode and when the SELF CLEAN, AIR PURIFIER and ANTI-MOULD special functionsare enabled.SELF CLEANPressing the TURBO button for more than 3 seconds enables the SELF CLEAN function.7. PURE/ANTI-MOULD BUTTONPUREPress this button to select the AIR PURIFIER function which uses the included HEPA (High Efficiency Particulate Air) filterto reduce the dust, bacteria and allergen content in the room.ANTI-MOULDPressing the PURE button for more than 3 seconds enables the ANTI-MOULD function.CAUTIONDo not touch the selector with wet hands (risk of personal injury due to electrocution).Do not start or stop the appliance by simply plugging it into the power socket or unplugging it (risk of personal injury due toelectrocution).Avoid prolonged direct exposure to the air flow (risk of personal injury due to sensitisation of the skin).SPECIAL FUNCTIONSAUTO-RESTARTThis function enables the dehumidifier to restart, after a power failure, from the last stored settings.ANTI-FROST FUNCTIONPrevents the evaporator from frosting, thereby extending the dehumidifier’s life and enhancing energy saving. When thisfunction is active, the fan continues to run while the compressor stops and ‘P1’ appears on the display.TANK FULL STOPPAGEThe dehumidifier stops when the condensate collection tank is full or incorrectly positioned. ‘P2’ displays together with indicatorlight .NOTE: when the compressor stops, it is necessary to wait 3 minutes before it restarts.ANTI-MOULD FUNCTIONHold the PURE button down for more than 3 seconds to enable this function. It sets the fan speed and hours of operation ofthe dehumidifier (up to 4h) in relation to the measured actual humidity. This maximises occupant comfort while reducing therisk of mould and bacterial growth.To disable the function, hold the PURE button down for more than 3 seconds or select an operating mode with the MODEbutton.SELF CLEANHold the TURBO button down for more than 3 seconds to enable this function; the displays reads SC for 5 seconds and thenclears.The SELF CLEAN function initiates as soon as the dehumidifier is switched off, and runs for 15 minutes; the display reads SCwhile the function is active.The function cleans and dries the heat exchangers with ventilation/dehumidification cycles, thus keeping them in perfectworking order.To deactivate SELF CLEAN, hold down the TURBO button for 3 seconds; SC flashes on the display for 5 seconds and thenclears.AIR PURIFIER FUNCTIONThis function significantly reduces the dust, bacterial and allergencontent of the room, using the HEPA (High Efficiency Particulate Air)filter supplied with the dehumidifier.Press the PURE button to activate the AIR PURIFIER function; all othermodes and special functions are inhibited while it is running. Makesure you have fitted the HEPA filter as indicated in fig.A .Fig.ACAUTIONIncorrectly installing the filter or forcing it into place can cause thedehumidifier to malfunction, overheat and even fail.26 /

GBCONDENSATE DISCHARGEThe dehumidifier can discharge the condensate water in two differentways:Fig. A1. DISCHARGE INTO TANKThe condensate water falls directly in the tank located in the lowersection of the dehumidifier. When the tank is full, the dehumidifierautomatically shuts down and the displays shows “P2” and the logo.PROCEDURE FOR EMPTYING THE TANK:- Pull out the tank slightly using the appropriate handles on the sides(Fig. A).- Pull the tank out fully while being careful not to spill the condensatewater.- Do not place the tank on the ground as its irregular underside maycause the water to spill out.- Empty out the water.- Put the tank back into its housing. The dehumidifier will automaticallystart functioning again.WARNING:- Do not remove the float (located inside the tank) when emptyingout the water.- Make sure to put the tank properly back into its housing (afterhaving emptied it).- Incorrectly fitting the tank can stop the dehumidifier starting(make sure the “P2” has cleared from the display). Beforeremoving the tank, it is advisable to tap the top part of thedehumidifier a few times to ensure that all the water has falleninto the tank. A few drops of water may nonetheless drip downonce the tank has been pulled out.- Before undertaking any operation on the appliance, make surethat the power supply has been disconnected.Fig. B2. CONTINUOUS DRAINAGEAllows for discharging the condensate water without letting it fallinto the collection tank. This function is particularly useful when thedehumidifier must be operated for long periods, making it difficult toempty the tank continuously.Fig. CINSTRUCTIONS- Remove the rubber cap from the right-hand outlet located on therear of the appliance (Fig. B).- Connect the hose (not included) with 13,5 mm internal diameterto the outlet (Fig.C). Make sure that the other end of the hoseterminates at a water collection point lying lower than the dischargeoutlet.- Switch the appliance on.CAUTION:To restore standard draining into the tank, make sure to refit the rubbercap into the hole on the rest of the unit./ 27

MANUALS