8. Dimensions All dimensions in mm I J K L M N Safety valve C/H and condensate Heating flow D.H.W. outlet Gas supply Cold water inlet Heating return Weight with packaging : 24 kW : 37 kg 30 kW : 40 kg Minimum space 450 mini required pour entretien 450mm 296 (24 kW) 360 (30 kW) Fig. 9 390 440mm NOTE: THE CLEARANCES STATED ABOVE ARE REQUIRED FOR SERVICING PURPOSES 12
9. Hydraulic data The boiler is fitted with an automatic by-pass as standard. The graphs (Fig. 10) show the development of the pressure available in relation to flow (on exit from the boiler). To ensure correct operation, the minimum flow of the appliance must be 300 l/h. (Thermostatic taps closed). Capacity of the installation. The water heater is fitted with a pressurised expansion vessel. Maximum volume of expansion vessel: 6 litres. Pressure: 1 bar. The volume of the expansion vessel in a pressurised appliance varies according to: - the average operating temperature in °C - the static height, which is the difference in metres between the highest point of the appliance and the expansion vessel axis. The minimum cold filling pressure of the appliance is 0.8 bar (recommended pressure between 1.0 and 1.5 bar). The pressure of the expansion vessel should always be greater than the static height (in metres) divided by 10. Pump Head Graph (15/50) 0.45 0.4 0.35 0.3 Pressure (bar) 0.25 0.2 0.15 0.1 0.05 0 0 200 400 600 800 1000 1200 1400 flow rate (l/hr) Pump Head Graph (15/60) Pressure (bar) flow rate (l/hr) Fig. 10 System capacity chart Central heating initial pressure when cold (in bar) 2.0 1.9 1,8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 80°C 70°C 60°C 50°C 40°C 20 40 60 80 100 120 140 160 180 200 220 240 System capacity (litres) 260 280 Fig. 11 13
63
Loading...
Loading...
8. Dimensions All dimensions in mm I J K L M N Safety valve C/H and condensate Heating flow D.H.W. outlet Gas supply Cold water inlet Heating return Weight with packaging : 24 kW : 37 kg 30 kW : 40 kg Minimum space 450 mini required pour entretien 450mm 296 (24 kW) 360 (30 kW) Fig. 9 390 440mm NOTE: THE CLEARANCES STATED ABOVE ARE REQUIRED FOR SERVICING PURPOSES 12
9. Hydraulic data The boiler is fitted with an automatic by-pass as standard. The graphs (Fig. 10) show the development of the pressure available in relation to flow (on exit from the boiler). To ensure correct operation, the minimum flow of the appliance must be 300 l/h. (Thermostatic taps closed). Capacity of the installation. The water heater is fitted with a pressurised expansion vessel. Maximum volume of expansion vessel: 6 litres. Pressure: 1 bar. The volume of the expansion vessel in a pressurised appliance varies according to: - the average operating temperature in °C - the static height, which is the difference in metres between the highest point of the appliance and the expansion vessel axis. The minimum cold filling pressure of the appliance is 0.8 bar (recommended pressure between 1.0 and 1.5 bar). The pressure of the expansion vessel should always be greater than the static height (in metres) divided by 10. Pump Head Graph (15/50) 0.45 0.4 0.35 0.3 Pressure (bar) 0.25 0.2 0.15 0.1 0.05 0 0 200 400 600 800 1000 1200 1400 flow rate (l/hr) Pump Head Graph (15/60) Pressure (bar) flow rate (l/hr) Fig. 10 System capacity chart Central heating initial pressure when cold (in bar) 2.0 1.9 1,8 1.7 1.6 1.5 1.4 1.3 1.2 1.1 1.0 80°C 70°C 60°C 50°C 40°C 20 40 60 80 100 120 140 160 180 200 220 240 System capacity (litres) 260 280 Fig. 11 13
63
Loading...
Loading...
CATALOGUE
PRODUCT BROCHURES
DATASHEETS
MANUALS
MANUALS (DISCONTINUED)
PLANNER MANUALS
CASE STUDIES