MAINTENANCE GUIDE Remove the gas pipe Remove the clip on th return pipe 6 9 Remove the screws on the side panel and open it. Bring down the return pipe and Rotate forward. Remove the return pipe. 10 7 Disconnect the condensate pipe from the exchanger, and turn it to the left Remove the nuts on the return and flow pipe on the top of the boiler 11 8 48 /
MAINTENANCE GUIDE Unscrew the four screws to remove the heat exchanger. Remove the clip and remove the flow pipe 12 15 Lower and remove the main exchanger 16 13 14 / 49