MAINTENANCE menu

MAINTENANCE menu sub-menu Parameter Description value default setting 6 ZONE 3 PARAMETER 6 0 ZONE 3 TEMPERATURE SETTING 6 0 2 Heating fixed temperature setting “Heating fixed temp” from 35 to 82 °C (high temperature - para. 420 =1) from 20 to 45 °C (high temperature - para. 420 =0) 6 2 ZONE 3 SETTING 6 2 0 Heating appliance temperature value setting 0 = from 20 to 45°C (low temper ature) 1 = from 35 to 85°C (high temperature) 6 2 1 Basic heating control type selection type depending on the peripheral devices connected 0 = fixed flow temperature 1 = device On/Off 2 = NOT PRESENT 3 = external sensor only 4 = NOT PRESENT 70 Activated only with temperature control and fixed temperature (see 621) 20 1 select in the appliance type base 1 To activate heating control, press the AUTO button. The display lights up the AUTO symbol 6 2 2 Slope from 0_2 to 0_8 (low temperature) from 1_0 to 3_5 1_5 (high temperature) - see graph on page 42 If the external sensor is used, the boiler calculates the most suitable heating flow temperature taking the external temperature and the type of appliance into account. The type of curve must be chosen according to the type of appliance radiator and the heat losses present in the building. 6 2 3 Parallel curve shift Zone 2 Offset from - 7 to + 7 (low temperature) 0 from - 14 to + 14 (high temperature) To adapt the thermal curve to the appliance requirements, it is possible to perform a parallel shift of the curve in order to alter the calculated flow temperature and therefore the ambient temperature. By accessing this parameter or pressing the buttons 12 the curve can be shifted in a parallel manner as indicated in the figure shown below. The value is indicated on the display: - from -7 to +7 (low temperature) - from -14 to +14 (high temperature) Each step represents a flow temperature increase/decrease of 1°C in relation to the set-point value. 6 2 4 Compensation from 0 to 20 20 if setting = 0, the temperature taken from the ambient sensor does not affect the calculation of the setting. If setting = 20, the temperature taken has maximum influence on the setting. 6 2 5 Zone 3 heating MAXIMUM temperature from 35 to 85 °C 82 if parameter 620 = 1 setting from 20 to 45 °C 45 if parameter 620 = 0 6 2 6 Zone 3 heating MINIMUM temperature setting 6 3 DIAGNOSTICS 6 3 4 Zone 3 heat request 0 = OFF 1 = ON from 35 to 85 °C 35 if parameter 620 = 1 from 20 to 45 °C 25 if parameter 620 = 0 40 /

MAINTENANCE menu sub-menu Parameter Description value default setting 8 SERVICE PARAMETERS 8 0 BOILER STATISTICS-1 8 0 0 Number of diverter valve cycles (n x10) NOT ACTIVE 8 0 1 Time of circulator on (h x 10) 8 0 2 Number of boiler circulator cycles (n x10) 8 0 3 Boiler Life Time (h x 10) 8 0 4 Time of fan ON (h x 10) 8 0 5 Number of fan cycles (n x10) 8 0 6 Number of flame detection in CH (n x10) 8 0 7 Number of flame detection in DHW (n x10) 8 1 BOILER STATISTICS-2 8 1 0 Number of hours burner operating in heater mode (xxh/10) 8 1 1 Number of hours burner operating in hot water mode (xxh/10) NOT ACTIVE 8 1 2 Number of flame separations (nr/10) 8 1 3 Number of ignition cycles (nr/10) 8 1 4 Average length of heating request (minutes) 8 2 BOILER 8 2 1 Fan Status 0 = OFF 1 = ON 8 2 2 Fan speed (x100) rpm 8 2 4 Diverter valve position NOT ACTIVE 8 2 7 Modulating Pump (%) NOT ACTIVE 8 2 8 Gas Power (kW) 8 3 BOILER TEMPERTURE 8 3 1 Heating flow temperature (in °C) 8 3 2 Heating backflow temperature (in °C) 8 4 SOLAR & STORAGE 8 4 2 Solar appliance water input temperature activated only with the solar kit connected 8 5 SERVICE 8 5 0 Months to next maintenance from 0 to 60 (month) 24 If setted the boiler will display that is time to call the installer for maintenance 8 5 1 Enable Maintenance advice 0 = OFF 0 1 = ON 8 5 2 Maintenance Warning Reset Reset? OK= Yes Esc = No to erase the advice for maintenance 8 5 3 2nd Heat Exchanger Clogging State 0 = DHW Exchanger OK 1 = Partially Clogged 2 = Very Clogged Please Replace 8 5 4 PCB hardware version 8 5 5 PCB software version 8 6 ERROR LIST 8 6 0 10 last errors from ERROR 0 to ERROR 9 This parameter allows the last 10 boiler errors flagged to be displayed, indicating the day, month and year. When the parameter is accessed, the errors are displayed listed from ERROR 0 to ERROR 9. For each error, the following sequence is displayed: E00 - error number 108 - error code 8 6 1 Error list reset Reset OK = yes ESC = no / 41

MANUALS