INSTALLATION

INSTALLATION INSTALLATION S plan wiring diagram. REMOTE 2 CHANNEL PROGRAMMER L N HW CH ON OFF ON OFF R/STAT CYL STAT Remove Link BUS TA2 SE TNK SOL TA1 Boiler TERMINAL STRIP Note: Boiler switching on TA1 is low voltage, use a seperate cable to supply TA1. Do not use 5 core cable. 240V 3AMP L N E Earths omitted for clarity L MOTOR L N N MOTOR H/W C/H 2 PORT 2 PORT VALVE VALVE 30 /

INSTALLATION S plan wiring diagram using an outside sensor. L N REMOTE 2 CHANNEL PROGRAMMER Outside sensor R/STAT CYL STAT Remove Links ON OFF ON OFF BUS TA2 SE TNK SOL TA1 Boiler 240V 3AMP L NE Earths omitted for clarity TERMINAL STRIP Change parameter: 223 from 0 to 1 521 from 1 to 3 421 from 1 to 0 Activate Auto Function Note: Boiler switching on TA1 & TA2 is low voltage. Use a separate cable to supply TA1 & TA2. Do not mix high voltage and low voltage wires in the same cable. MOTOR C/H 2 PORT VALVE L N MOTOR L N H/W 2 PORT VALVE / 31