product description Overall Dimensions 200 200 120 120 96,5 70,7 52 122 25 665 595 135 162 44.5 161 292 (12-18-24 kW) 362 (30 kW) 450 250 5 5 Minimum clearances In order to allow easy access to the boiler for maintenance operations, the boiler must be installed in accordance with the clearances stated. 300
Technical Data product description GENERAL NOTE POWER SPECIFICATIONS EMISSIONS HEATING CIRCUIT ELECTRICAL Model CLAS HE R 12 18 CE Certification (pin) 0085BR0347 Boiler type B23-B23p-B33-C13-C33- C43-C53-C83 Max/min nominal calorific flow rate (Pci) Qn kW 12.0/3.0 18.0/4.5 Max/min nominal calorific flow rate (Pcs) Qn kW 13.3/3.3 20.0/5.0 Max/min power output (80°C-60°C) Pn kW 11.7/2.8 17.6/4.3 Max/min power output (50°C-30°C) Pn kW 12.9/3.2 19.1/4.7 Combustion efficiency (of flue gas) % 97.8 97.6 Nominal calorific flow rate efficiency (60/80°C) Hi/Hs % 97.6/87.9 97.7/88.0 Nominal calorific flow rate efficiency (30/50°C) (condensation) Hi/Hs % 107.1/96.4 106.2/95.6 Efficiency at 30% at 30°C (condensation) Hi/Hs % 108.7/97.9 107.8/97.1 Efficiency at 30% at 47°C Hi/Hs % 99.2/89.3 101.9/91.8 Minimum calorific flow rate efficiency (60/80°C) Hi/Hs % 94.3/84.9 94.7/85.3 Efficiency rating (dir. 92/42/EEC) stars **** **** Sedbuk Band Rating band/% A / 90.1 A / 90.1 Loss when stopped (∆T = 50°C) % 0.3 0.2 Loss of burner gas when operating % 2.2 2.4 Available air pressure Pa 53 91 NoX class (less than 70mg/kWh) class 5 5 Flue gas temperature (G20) (80°C-60°C) °C 65 69 CO2 content (G20) (80°C-60°C) % 9.0 9.2 CO content (0%O2) (80°C-60°C) ppm < 80 < 170 O2 content (G20) (80°C-60°C) % 4.5 4.2 Maximum flue gas flow (G20) (80°C-60°C) Kg/h 19.8 29.1 Excess air (80°C-60°C) % 27 25 Minimum/Maximum heating pressure bar 0,2/3 0,2/3 Min/max heating temperature (high temperature range) °C 35/82 35/82 Min/max heating temperature (low temperature range) °C 20/45 20/45 Power supply frequency/voltage V/Hz 230/50 230/50 Total electrical power absorbed W 135 142 Minimum ambient temperature for use °C +5 +5 Protection level for the electrical appliance IP X5D X5D Weight kg 23 23
MAINTENANCE GUIDE 4.5 GAS VALVE Too
GAS BOILER SYSTEM COMMISSIONING CHE
SHORT LIST 173 110 SHORT LIST 171 8
Loading...
Loading...
product description Overall Dimensions 200 200 120 120 96,5 70,7 52 122 25 665 595 135 162 44.5 161 292 (12-18-24 kW) 362 (30 kW) 450 250 5 5 Minimum clearances In order to allow easy access to the boiler for maintenance operations, the boiler must be installed in accordance with the clearances stated. 300
Technical Data product description GENERAL NOTE POWER SPECIFICATIONS EMISSIONS HEATING CIRCUIT ELECTRICAL Model CLAS HE R 12 18 CE Certification (pin) 0085BR0347 Boiler type B23-B23p-B33-C13-C33- C43-C53-C83 Max/min nominal calorific flow rate (Pci) Qn kW 12.0/3.0 18.0/4.5 Max/min nominal calorific flow rate (Pcs) Qn kW 13.3/3.3 20.0/5.0 Max/min power output (80°C-60°C) Pn kW 11.7/2.8 17.6/4.3 Max/min power output (50°C-30°C) Pn kW 12.9/3.2 19.1/4.7 Combustion efficiency (of flue gas) % 97.8 97.6 Nominal calorific flow rate efficiency (60/80°C) Hi/Hs % 97.6/87.9 97.7/88.0 Nominal calorific flow rate efficiency (30/50°C) (condensation) Hi/Hs % 107.1/96.4 106.2/95.6 Efficiency at 30% at 30°C (condensation) Hi/Hs % 108.7/97.9 107.8/97.1 Efficiency at 30% at 47°C Hi/Hs % 99.2/89.3 101.9/91.8 Minimum calorific flow rate efficiency (60/80°C) Hi/Hs % 94.3/84.9 94.7/85.3 Efficiency rating (dir. 92/42/EEC) stars **** **** Sedbuk Band Rating band/% A / 90.1 A / 90.1 Loss when stopped (∆T = 50°C) % 0.3 0.2 Loss of burner gas when operating % 2.2 2.4 Available air pressure Pa 53 91 NoX class (less than 70mg/kWh) class 5 5 Flue gas temperature (G20) (80°C-60°C) °C 65 69 CO2 content (G20) (80°C-60°C) % 9.0 9.2 CO content (0%O2) (80°C-60°C) ppm < 80 < 170 O2 content (G20) (80°C-60°C) % 4.5 4.2 Maximum flue gas flow (G20) (80°C-60°C) Kg/h 19.8 29.1 Excess air (80°C-60°C) % 27 25 Minimum/Maximum heating pressure bar 0,2/3 0,2/3 Min/max heating temperature (high temperature range) °C 35/82 35/82 Min/max heating temperature (low temperature range) °C 20/45 20/45 Power supply frequency/voltage V/Hz 230/50 230/50 Total electrical power absorbed W 135 142 Minimum ambient temperature for use °C +5 +5 Protection level for the electrical appliance IP X5D X5D Weight kg 23 23
MAINTENANCE GUIDE 4.5 GAS VALVE Too
GAS BOILER SYSTEM COMMISSIONING CHE
SHORT LIST 173 110 SHORT LIST 171 8
Loading...
Loading...
CATALOGUE
PRODUCT BROCHURES
DATASHEETS
INSTALLATION MANUALS
MANUALS (DISCONTINUED)
PLANNER MANUALS
CASE STUDIES