Views
2 years ago

CLAS HE R - Installation & Servicing Manual

  • Text
  • Wwwaristoncom
  • Manual
  • Servicing
  • Clas
  • Terminal
  • Installation
  • Appliance
  • Heating
  • Boiler
  • Flue

settings - adjustment -

settings - adjustment - problem identification menus menu sub-menu parameter description value 5 ZONE 2 PARAMETER 5 0 ZONE 2 TEMPERATURE SETTING 5 0 0 NOT PRESENT 5 0 1 NOT PRESENT 5 0 2 NOT PRESENT 5 1 Entering access code 222 press the programming "+" button to select 234 and press the Menu button 5 2 CYLINDER SETTING 5 2 0 Heating appliance temperature value setting 0 = from 20 to 45°C (low temperature) 1 = from 35 to 85°C (high temperature) 5 2 1 Basic heating control type selection 0 = fixed flow temperature type depending on the peripheral 1 = device On/Off devices connected 2 = ambient sensor only 3 = external sensor only 4 = ambient sensor + external sensor 5 2 2 NOT PRESENT 5 2 3 NOT PRESENT 5 2 4 NOT PRESENT 5 2 5 Zone 2 heating maximum temperature setting 5 2 6 Zone 2 heating minimum temperature setting 5 3 DIAGNOSTICS 5 3 0 NOT PRESENT 5 3 1 NOT PRESENT 5 3 2 NOT PRESENT 5 3 3 Zone 2 set temperature 5 3 4 Zone 2 heat request 0=OFF 1=ON 5 3 5 Zone 2 Pump status 0=OFF 1=ON 5 4 ZONE DEVICE MANAGEMENT 5 4 0 NOT PRESENT 5 4 1 NOT PRESENT 5 4 2 NOT PRESENT 5 5 MULTIZONE 5 5 0 NOT PRESENT 5 5 1 NOT PRESENT default setting 1 select in the appliance type base 0 To activate heating control, press the AUTO button. The Auto light is illuminate 35 to + 82°C 82 if parameter 420 = 1 20 to + 45°C 45 if parameter 420 = 0 35 to + 82°C 35 if parameter 420 = 1 20 to + 45°C 20 if parameter 420 = 0 46

settings - adjustment - problem identification menus menu sub-menu parameter description 7 TEST & UTILITIES 7 0 0 Function test - Cleaning turn the encoder to select the operating mode 7 0 1 Bleed cycle press Menu 8 PARAMETER FOR TECHNICAL ASSISTANCE value default setting t-- = funct. at Max heating power t-- activation can also be obtained by pressing the Reset button for 10 seconds. The function is deactivated after 10 minutes or by pressing Reset 8 1 Entering access code 222 press the programming "+" button to select 234 and press the Menu button 8 2 BOILER 8 2 0 NOT PRESENT 8 2 1 Fan status ON or OFF 8 2 2 Fan speed (x100) rpm 8 2 3 NOT PRESENT 8 2 4 NOT PRESENT 8 2 5 NOT PRESENT 8 2 6 NOT PRESENT 8 3 BOILER TEMPERATURE 8 3 0 Heating adjustment temperature (°C) 8 3 1 Heating flow temperature (in °C) 8 3 2 Heating backflow temperature (in °C) 8 3 3 NOT PRESENT 8 4 SOLAR APPLIANCE AND TANK 8 4 0 NOT PRESENT 8 4 1 NOT PRESENT 8 4 2 NOT PRESENT 8 4 3 NOT PRESENT 8 4 4 NOT PRESENT 8 4 5 NOT PRESENT 8 4 6 NOT PRESENT 8 5 SERVICE - TECHNICAL ASSISTANCE 8 5 0 NOT PRESENT 8 5 1 NOT PRESENT 8 5 2 NOT PRESENT 8 5 3 NOT PRESENT 8 5 4 PCB hardware version 8 5 5 PCB software version 8 5 6 NOT PRESENT 47

INSTALLATION MANUALS

Views
2 years ago

CLAS HE R - Installation & Servicing Manual

  • Text
  • Wwwaristoncom
  • Manual
  • Servicing
  • Clas
  • Terminal
  • Installation
  • Appliance
  • Heating
  • Boiler
  • Flue

settings - adjustment -

settings - adjustment - problem identification menus menu sub-menu parameter description value 5 ZONE 2 PARAMETER 5 0 ZONE 2 TEMPERATURE SETTING 5 0 0 NOT PRESENT 5 0 1 NOT PRESENT 5 0 2 NOT PRESENT 5 1 Entering access code 222 press the programming "+" button to select 234 and press the Menu button 5 2 CYLINDER SETTING 5 2 0 Heating appliance temperature value setting 0 = from 20 to 45°C (low temperature) 1 = from 35 to 85°C (high temperature) 5 2 1 Basic heating control type selection 0 = fixed flow temperature type depending on the peripheral 1 = device On/Off devices connected 2 = ambient sensor only 3 = external sensor only 4 = ambient sensor + external sensor 5 2 2 NOT PRESENT 5 2 3 NOT PRESENT 5 2 4 NOT PRESENT 5 2 5 Zone 2 heating maximum temperature setting 5 2 6 Zone 2 heating minimum temperature setting 5 3 DIAGNOSTICS 5 3 0 NOT PRESENT 5 3 1 NOT PRESENT 5 3 2 NOT PRESENT 5 3 3 Zone 2 set temperature 5 3 4 Zone 2 heat request 0=OFF 1=ON 5 3 5 Zone 2 Pump status 0=OFF 1=ON 5 4 ZONE DEVICE MANAGEMENT 5 4 0 NOT PRESENT 5 4 1 NOT PRESENT 5 4 2 NOT PRESENT 5 5 MULTIZONE 5 5 0 NOT PRESENT 5 5 1 NOT PRESENT default setting 1 select in the appliance type base 0 To activate heating control, press the AUTO button. The Auto light is illuminate 35 to + 82°C 82 if parameter 420 = 1 20 to + 45°C 45 if parameter 420 = 0 35 to + 82°C 35 if parameter 420 = 1 20 to + 45°C 20 if parameter 420 = 0 46

settings - adjustment - problem identification menus menu sub-menu parameter description 7 TEST & UTILITIES 7 0 0 Function test - Cleaning turn the encoder to select the operating mode 7 0 1 Bleed cycle press Menu 8 PARAMETER FOR TECHNICAL ASSISTANCE value default setting t-- = funct. at Max heating power t-- activation can also be obtained by pressing the Reset button for 10 seconds. The function is deactivated after 10 minutes or by pressing Reset 8 1 Entering access code 222 press the programming "+" button to select 234 and press the Menu button 8 2 BOILER 8 2 0 NOT PRESENT 8 2 1 Fan status ON or OFF 8 2 2 Fan speed (x100) rpm 8 2 3 NOT PRESENT 8 2 4 NOT PRESENT 8 2 5 NOT PRESENT 8 2 6 NOT PRESENT 8 3 BOILER TEMPERATURE 8 3 0 Heating adjustment temperature (°C) 8 3 1 Heating flow temperature (in °C) 8 3 2 Heating backflow temperature (in °C) 8 3 3 NOT PRESENT 8 4 SOLAR APPLIANCE AND TANK 8 4 0 NOT PRESENT 8 4 1 NOT PRESENT 8 4 2 NOT PRESENT 8 4 3 NOT PRESENT 8 4 4 NOT PRESENT 8 4 5 NOT PRESENT 8 4 6 NOT PRESENT 8 5 SERVICE - TECHNICAL ASSISTANCE 8 5 0 NOT PRESENT 8 5 1 NOT PRESENT 8 5 2 NOT PRESENT 8 5 3 NOT PRESENT 8 5 4 PCB hardware version 8 5 5 PCB software version 8 5 6 NOT PRESENT 47