installation Electrical diagram For increased safety, ask a qualified technician to perform a thorough check of the electrical system. The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply. Peripheral unit Peripheral unit connection CLAS HE EVO LV connections 1 1 CN14 CN3 1 CN25 1 CN8 CN9 1 CN6 1 T B FLOOR BUS TA2 SE TNK SOL TA1 1 CN1 CN19 FLAME N L N L CN4 1 1 HV connections BUS - Remote Control (modulating device) TA2/FLOOR - Underfloor heating thermostat Room Thermostat 2 SE - Outdoor Sensor SOL - Solar temperature probe TA1 - Room thermostat 1 CN11 T B BUS TA2 SE TNK SOL TA1 CN1 1 HV connection Gr Detection electrode CN19 FLAME N N L L Bk Bl Bk Rd Wh Modulating Fan CN4 LV connection 1 Ignitor Display C.H. Return temp. probe C.H. Flow temp. probe Bl Bl Rd Rd 1 1 CN14 CN3 CN2 CN11 1 Bk Bk Br Br Bl Bk Bk Bk Bl Diverter valve Gas valve Thermal fuse Br Br CN9 1 Circulation Pump CN6 1 CN25 1 1 CN8 D.H.W. flow switch Bk Bk Switch ON/OFF Bk Br 28

installation CLAS HE EVO SYSTEM Peripheral unit Peripheral unit connection LV connections 1 1 CN14 CN3 1 CN25 1 CN8 CN9 1 CN6 1 T B FLOOR BUS TA2 SE TNK SOL TA1 1 CN1 CN19 FLAME N L N L CN4 1 1 HV connections BUS - Remote Control (modulating device) TA2/FLOOR - Underfloor heating thermostat Room Thermostat 2 SE - Outdoor Sensor SOL - Solar temperature probe TA1 - Room thermostat 1 CN11 T B BUS TA2 SE TNK SOL TA1 CN1 1 HV connection Gr Detection electrode CN19 FLAME N N L L Bk Bl Bk Rd Wh Modulating Fan CN4 LV connection 1 Ignitor Display C.H. Return temp. probe C.H. Flow temp. probe Bl Bl Rd Rd 1 1 CN14 CN3 CN2 CN11 1 Bk Bk Bk Bk Br Bl Gas valve Thermal fuse Br Br CN9 1 Circulation Pump CN6 1 CN25 1 1 CN8 Switch ON/OFF Bk Br 29

Views
3 years ago

CLAS HE Evo & CLAS HE System Evo - Installation & Servicing Manual

  • View more details
  • Wwwaristoncom
  • Manual
  • Servicing
  • Clas
  • Domestic
  • Maintenance
  • Maximum
  • Parameter
  • Valve
  • Installation
  • Appliance
  • Flue
  • Heating
  • Boiler

installation Electrical

installation Electrical diagram For increased safety, ask a qualified technician to perform a thorough check of the electrical system. The manufacturer is not responsible for any damage caused by the lack of a suitable earthing system or by the malfunctioning of the electricity mains supply. Peripheral unit Peripheral unit connection CLAS HE EVO LV connections 1 1 CN14 CN3 1 CN25 1 CN8 CN9 1 CN6 1 T B FLOOR BUS TA2 SE TNK SOL TA1 1 CN1 CN19 FLAME N L N L CN4 1 1 HV connections BUS - Remote Control (modulating device) TA2/FLOOR - Underfloor heating thermostat Room Thermostat 2 SE - Outdoor Sensor SOL - Solar temperature probe TA1 - Room thermostat 1 CN11 T B BUS TA2 SE TNK SOL TA1 CN1 1 HV connection Gr Detection electrode CN19 FLAME N N L L Bk Bl Bk Rd Wh Modulating Fan CN4 LV connection 1 Ignitor Display C.H. Return temp. probe C.H. Flow temp. probe Bl Bl Rd Rd 1 1 CN14 CN3 CN2 CN11 1 Bk Bk Br Br Bl Bk Bk Bk Bl Diverter valve Gas valve Thermal fuse Br Br CN9 1 Circulation Pump CN6 1 CN25 1 1 CN8 D.H.W. flow switch Bk Bk Switch ON/OFF Bk Br 28

installation CLAS HE EVO SYSTEM Peripheral unit Peripheral unit connection LV connections 1 1 CN14 CN3 1 CN25 1 CN8 CN9 1 CN6 1 T B FLOOR BUS TA2 SE TNK SOL TA1 1 CN1 CN19 FLAME N L N L CN4 1 1 HV connections BUS - Remote Control (modulating device) TA2/FLOOR - Underfloor heating thermostat Room Thermostat 2 SE - Outdoor Sensor SOL - Solar temperature probe TA1 - Room thermostat 1 CN11 T B BUS TA2 SE TNK SOL TA1 CN1 1 HV connection Gr Detection electrode CN19 FLAME N N L L Bk Bl Bk Rd Wh Modulating Fan CN4 LV connection 1 Ignitor Display C.H. Return temp. probe C.H. Flow temp. probe Bl Bl Rd Rd 1 1 CN14 CN3 CN2 CN11 1 Bk Bk Bk Bk Br Bl Gas valve Thermal fuse Br Br CN9 1 Circulation Pump CN6 1 CN25 1 1 CN8 Switch ON/OFF Bk Br 29