Ariston Vertical Flue Positions

  • Text
  • Ariston
  • Vertical
  • Flue
  • Positions
  • Www.ariston.com

Ariston Vertical Flue Positions

Reference: TB 105 09/22 Technical Bulletin ARISTON VERTICAL TERMINAL POSITIONS: Ariston Vertical Flue Positions Vertical Flue Termination The terminal must be at least 1,500mm from the opening or vent when sited below the window or 600mm when sited to either side or above. A = 600mm B = 1,500mm 500mm clearance measured horizontally from a vertical flue to a vertical structure. =500mm 665mm measured vertically to the closest intersection with the roof =665mm TECHNICAL HELPDESK techhelpdesk@aristonthermo.com Phone: 0333 240 7777 At the time of this bulletin being issued all information was correct and aligned with Ariston Group and Ariston UK. This technical bulletin is only to be circulated within British Gas. This technical bulletin applies to the below GC numbers: Clas One Net 24 Clas one Net 30 Clas One Net 38 Clas One 24 Clas One 30 Clas One 38 Clas One System 18 Clas One System 24 47-116-88 47-116-89 47-116-90 47-116-85 47-116-86 47-116-87 41-116-49 41-116-50 Genus One 30 Clas One R 24 Clas One System 30 E-Combi One 24 E-Combi One 30 E-System One 24 E- System One 30 47-116-94 41-116-52 41-116-51 47-116-83 47-116-84 41-116-47 41-116-48 Alteas One Net 30 Alteas One Net 35 Genus One 24 Genus One 35 47-116-91 47-116-92 47-116-93 47-116-95 Version Date of issue Date of revision Author 1.0 02/09/2022 26/08/2023 Adam Perry