Views
1 year ago

Ariston Thermo - Hot Water

  • Text
  • Heater
  • X
  • Fi
  • Evo
  • Multi
  • Lux
  • Aures
  • Andris
  • Slim
  • Ariston
  • Velis

NEXT EVO X ITALIAN

NEXT EVO X ITALIAN DESIGN FLAT ENERGY EFFICIENT LED DISPLAY ELECTRONIC TEMPERATURE MANAGEMENT TYPICAL APPLICATIONS / Kitchens & bathrooms / Loft conversions / Utility rooms Next Evo X is a gas instantaneous water heater featuring a premium Italian design and LED display with easy user interface. / Oxygen free copper heat exchanger / Built-in temperature stabilisation / Ultra compact – from 165mm in depth / Low NOx emissions with lean-rich burner / Energy-saving ECO function / Post ventilation system & overheat sensor for safety / Available in 11L LPG & 16L Natural Gas models* / Low minimum water pressure at 0.2 bar / Low minimum working flow rate at 2.5l/min / Conversion kits available for both models *Gas conversion kits available ENERGY RATING 40 39 40 17 39 36 A 17 570 36 570 570 570 A A A A M & XL 42 129 Ø100 Ø60 85 130 180 Ø100 Ø60 32 138 129 42 129 85 130 180 345 Ø100 Ø60 32 138 129 345 85 130 Ø100 180 Ø60 85 130 180 345 345 D 156 D 156 C C C C 600 46 600 600 46 616 600 616 616 616 71 79 71 79 165 187 165 187 NEXT EVO X - 11 650 658 A B C D 658 40 40 39 39 17 36 36 187 570 17 570 93 570 187 570 87 87 A NEXT EVO X - 16 650 93 A A A 42 129 Ø100 Ø60 85 130 Ø100 180 Ø60 32 138 129 345 85 Ø100 130 Ø60 180 345 D 156 B156 C A A Ø100 C 32 Ø60 B 138 129 A A 42 129 85 130 180 345 85 130 180 345 B B C C D D C D 58 600 600 58 46 46 C 67 77 600 67 616 77 600 616 90 NEXT EVO X 1/2" domestic hot water outlet C 90 616 616 1/2" gas inlet 1/2" cold water inlet Drain valve WATER CIRCUIT DIAGRAM 71 71 79 79 165 165 187 187 650 658 658 650 187 187 93 93 87 87 A A A A B TECHNICAL DATA 11 16 Efficiency ERP Rating Load Profile C Gas Type B Weight (kg) Maximum Nominal Heat Input (kW) Minimum Nominal Heat Input (kW) C Minimum Working Pressure (bar) B Minimum Operating Flow Rate (l/min) Nominal Flow Rate with ∆T@25°C (l/min) Power Supply Voltage/Frequency (V/Hz) Nominal Noise Level (dB) IPX Protection Level Max Outlet Water Temperature (°C) Min Outlet Water Temperature (°C) Ambient Minimum Working Temperature (°C) 58 Overall D Dimensions (H x W x D) (mm) D 58 C 67 67 77 77 Product Code 90 Table of flue gas exhaust duct lengths C B Maximum Extension Exhaust-air (m) 90 Type MIN NEXT EVO X 11/16 MAX Diameter of pipe (mm) C13 0.6 8 60/100 Flues and accessories A M LPG 13.0 22.0 8.0 0.2 2.5 11.0 230 / 50 58.0 IPX2 65.0 35.0 5.0 570x345x165 Code Description 3318000 Horizontal Flue Kit 60/100 (SE) 3319050 Vertical Starter with Horizontal Terminal Kit 60/100 (SE) 3318003 90° Coaxial Elbow (SE) 3318004 45° Coaxial Elbow (Pack of 2) (SE) 3318005 Coaxial Extension - 1000mm (SE) 3318006 Coaxial Extension - 500mm (SE) 3318007 Coaxial Extension - 250mm (SE) 3318008 Vertical Starter (SE) 3318855 Vertical Flue with Black Terminal 60/100 (SE) 3632495 Conversion Kit from LPG to NG (For 11 Model) 3632498 Conversion Kit from NG to LPG (For 16 Model) 3318009 Black Lead Flashing Base Cap 18-44° 3318011 Black Vent Cap Base for Flat Roof 3318015 Wall Bracket Kit (80 - 125mm) (Pack of 3) 3024085 Thermostatic Mixing Valve 3/4" 35-60°C A XL Natural Gas 15.0 30.0 9.5 0.2 2.5 16.0 230 / 50 63.0 IPX2 65.0 35.0 5.0 570x345x187 3632535 3632533 Electrical connections 50 1 2 3 4 5 6 A B C 11 10 9 8 7 Legend 1 Heat exchanger 2 Detection electrode 3 Burner 4 Fan 5 Outgoing water temperature sensor 6 Overheat thermostat 7 Cold water inlet filter 8 Inlet water temperature probe 9 Water flow switch 10 Gas valve 11 Ignition electrode The power supply cable must be connected to a 230V-50Hz network, where the L-N poles and the earth connection are all respected. 140 Rear spacer installation Orientation 1 - To achieve 80mm standoff 200 120 H05VV-F 3G 80 40 Orientation 2 - To achieve 40mm standoff 200 40 80

CONTACTS

Social Media