Ariston Plume Terminal Siting

Ariston Plume Terminal

Reference: TB 103 08/22 Technical Bulletin ARISTON PLUME TERMINAL SITING: Ariston Plume Terminal Siting Minimum siting dimensions for plume kit termination Minimum air inlet termination Directly below an opening, air brick or opening window Directly above an opening, air brick or opening window Horizontally to an opening, air brick or opening window Minimum outlet termination Directly below an opening, air brick or opening window Directly above an opening, air brick or opening window Horizontally to an opening, air brick or opening window 150mm 300mm 150mm 300mm 300mm 300mm Plume Kit Reductions Reduction to maximum plume length for each 45 degree bend is: 0.5m Maximum plume length is: 3.0m Minimum plume length is: 0.5m TECHNICAL HELPDESK techhelpdesk@aristonthermo.com Phone: 0333 240 7777 At the time of this bulletin being issued all information was correct and aligned with Ariston Group and Ariston UK. This technical bulletin is only to be circulated within British Gas. Version Date of issue Date of revision Author 1.0 26/08/2022 26/08/2023 Adam Perry