TECHNICAL DATA 35 50 80 120 150 PERFORMANCES IN HEATING* Capacity at A-7 / W35 (Min./Nom./Max.) kW 1.04 / 3.51 / 4.52 1.04 / 5 / 5.20 1.79 / 7.41 / 8.45 2.73 / 9.51 / 11.47 2.99 / 11 / 13.79 COP nom at A-7 / W35 - 3.1 2.9 3.0 3.2 3.1 Capacity at A2 / W45 (Min./Nom./Max.) kW 1.31 / 2.55 / 5.68 1.33 / 3 / 6.33 2.3 / 4.60 / 10.21 3.37 / 6.35 / 13.01 3.43 / 7.50 / 15.99 COP nom at A2 / W45 - 3.05 3.00 3.15 3.35 3.25 Capacity at A+7 / W35 (Min./Nom./Max.) kW 1.68 / 3.5 / 6.35 1.68 / 5 / 7.57 2.74 / 8 / 11.74 4.23 / 12 / 14.37 4.08 / 15 / 17.65 COP nom at A+7 / W35 - 5.1 5.0 4.8 4.9 4.7 Operating temperature (air) Min./Max – Heating mode °C -20 / 35 -20 / 35 -20 / 35 -20 / 36 -20 / 37 Flow temperature (water) Min./Max – Heating mode °C 20 / 60 20 / 60 20 / 60 21 / 60 22 / 60 PERFORMANCES IN COOLING* Capacity at A35 / W7 (Min./Nom./Max.) kW 1.16 / 3.5 / 4.04 1.16 / 5 / 5.33 2.45 / 7 / 8.54 3.30 / 9.05 / 10.45 3.30 / 11 / 13.30 EER nom at A35 / W7 - 3.4 2.9 3.1 3.2 2.9 Capacity at A35 / W18 (Min./Nom./Max.) kW 2.16 / 4.08 / 6.50 2.16 / 4.63 / 7.86 3.31 / 7 / 11.73 4.90 / 10.74 / 15.51 4.90 / 12.5 / 17.98 EER nom at A35 / W18 - 5.3 4.6 4.7 2.9 4.7 NIMBUS PLUS M NET R32 35 50 80 120 150 ErP Energy class in heating 35°C / 55°C A+++/A++ A+++/A++ A+++/A++ A+++/A++ A+++/A+++ CODE SINGLE PHASE 3301846 3301847 3301848 3301850 3301852 CODE THREE PHASE - - 3301849 3301851 3301853 SELECTION GUIDE FOR COMBINATION WITH SANITARY TANK 1 Choose the heat pump PLUS M 2 Choose the DHW tank 3 Order the DHW kit (code 3319671) 4 Order the DHW tank probe (code 3318962) * Data according to EN 14511 TECHNICAL DATA 35 50 80 120 150 716 mm Voltage/frequency (1-ph) v/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Voltage/frequency (3-ph) v/ph/Hz - - 400/3/50 400/3/50 400/3/50 Sound power level internal unit dB(A) 35 35 35 35 35 Weight kg 29 29 29 31 31 Heating element kW 2+2 2+2 2+2 2+2+2 2+2+2 Fittings circuit heating/DHW 1"/ 3/4"M 1"/ 3/4"M 1"/ 3/4"M 1"/ 3/4"M 1"/ 3/4"M Flow rate min/nom l/h 4.10 4.10 4.10 6.10 6.10 Max absorbed power kW 480/640 650/860 1050/1400 1580/2100 1950/2600 Expansion vessel capacity l 12 12 12 12 12 Minimum water quantity l 17.5 25 40 60 75 LEGEND: 600 mm A 358 mm E F 1 / External unit 2 / Internal unit 3 / Magnetic filter 4 / System interface Sensys HD 5 / Connectivity Light Gateway 6 / External probe 7 / Antifreeze kit 8 / Valves 9 / By-pass valve 10 / Heating/cooling zone 6 3 F VE 2 5 4 250 mm 202 mm 79 mm Z1 IN B C 74 mm 237 mm 309 mm 461 mm 538 mm B A D OUT Z1 OUT 1 8 7 9 10 Nimbus Plus M Net R32/datasheet/Feb 24 | 2
Loading...
Loading...
TECHNICAL DATA 35 50 80 120 150 PERFORMANCES IN HEATING* Capacity at A-7 / W35 (Min./Nom./Max.) kW 1.04 / 3.51 / 4.52 1.04 / 5 / 5.20 1.79 / 7.41 / 8.45 2.73 / 9.51 / 11.47 2.99 / 11 / 13.79 COP nom at A-7 / W35 - 3.1 2.9 3.0 3.2 3.1 Capacity at A2 / W45 (Min./Nom./Max.) kW 1.31 / 2.55 / 5.68 1.33 / 3 / 6.33 2.3 / 4.60 / 10.21 3.37 / 6.35 / 13.01 3.43 / 7.50 / 15.99 COP nom at A2 / W45 - 3.05 3.00 3.15 3.35 3.25 Capacity at A+7 / W35 (Min./Nom./Max.) kW 1.68 / 3.5 / 6.35 1.68 / 5 / 7.57 2.74 / 8 / 11.74 4.23 / 12 / 14.37 4.08 / 15 / 17.65 COP nom at A+7 / W35 - 5.1 5.0 4.8 4.9 4.7 Operating temperature (air) Min./Max – Heating mode °C -20 / 35 -20 / 35 -20 / 35 -20 / 36 -20 / 37 Flow temperature (water) Min./Max – Heating mode °C 20 / 60 20 / 60 20 / 60 21 / 60 22 / 60 PERFORMANCES IN COOLING* Capacity at A35 / W7 (Min./Nom./Max.) kW 1.16 / 3.5 / 4.04 1.16 / 5 / 5.33 2.45 / 7 / 8.54 3.30 / 9.05 / 10.45 3.30 / 11 / 13.30 EER nom at A35 / W7 - 3.4 2.9 3.1 3.2 2.9 Capacity at A35 / W18 (Min./Nom./Max.) kW 2.16 / 4.08 / 6.50 2.16 / 4.63 / 7.86 3.31 / 7 / 11.73 4.90 / 10.74 / 15.51 4.90 / 12.5 / 17.98 EER nom at A35 / W18 - 5.3 4.6 4.7 2.9 4.7 NIMBUS PLUS M NET R32 35 50 80 120 150 ErP Energy class in heating 35°C / 55°C A+++/A++ A+++/A++ A+++/A++ A+++/A++ A+++/A+++ CODE SINGLE PHASE 3301846 3301847 3301848 3301850 3301852 CODE THREE PHASE - - 3301849 3301851 3301853 SELECTION GUIDE FOR COMBINATION WITH SANITARY TANK 1 Choose the heat pump PLUS M 2 Choose the DHW tank 3 Order the DHW kit (code 3319671) 4 Order the DHW tank probe (code 3318962) * Data according to EN 14511 TECHNICAL DATA 35 50 80 120 150 716 mm Voltage/frequency (1-ph) v/ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Voltage/frequency (3-ph) v/ph/Hz - - 400/3/50 400/3/50 400/3/50 Sound power level internal unit dB(A) 35 35 35 35 35 Weight kg 29 29 29 31 31 Heating element kW 2+2 2+2 2+2 2+2+2 2+2+2 Fittings circuit heating/DHW 1"/ 3/4"M 1"/ 3/4"M 1"/ 3/4"M 1"/ 3/4"M 1"/ 3/4"M Flow rate min/nom l/h 4.10 4.10 4.10 6.10 6.10 Max absorbed power kW 480/640 650/860 1050/1400 1580/2100 1950/2600 Expansion vessel capacity l 12 12 12 12 12 Minimum water quantity l 17.5 25 40 60 75 LEGEND: 600 mm A 358 mm E F 1 / External unit 2 / Internal unit 3 / Magnetic filter 4 / System interface Sensys HD 5 / Connectivity Light Gateway 6 / External probe 7 / Antifreeze kit 8 / Valves 9 / By-pass valve 10 / Heating/cooling zone 6 3 F VE 2 5 4 250 mm 202 mm 79 mm Z1 IN B C 74 mm 237 mm 309 mm 461 mm 538 mm B A D OUT Z1 OUT 1 8 7 9 10 Nimbus Plus M Net R32/datasheet/Feb 24 | 2
Loading...
Loading...
CATALOGUE
PRODUCT BROCHURES
DATASHEETS
MANUALS
MANUALS (DISCONTINUED)
PLANNER MANUALS
CASE STUDIES