CASE STUDY Image by rawpixel.com on Freepik Canopy Housing LEEDS IMS Heat Pumps Pos. Description 1 Buffer tank 4 attacks with T probe 2 Radiators 3 Circulator generic - 3 wires 4 HE kit below odu + drain pan 5 DHW tank hhp 1-coil with T probe and anode 6 System interface 7 Light gateway 8 Heating-dhw 3-way valve 9 External unit hhp - Monobloc 1 -ph or 3-ph 10 Kit valves and filter 11 Kit anti-freeze 12 Kit he idu fs 2 kw 13 Lightbox 14 Safety group 15 Expansion vessel - DHW 16 Expansion vessel - heating 17 Thermostatic mixing valve 18 External probe - This schematic has to be considered as example of the system functionality only and does not replace design by a qualified technician; - The final schematic must be prepared respecting all the laws, norms and decrees in force, in order to facilitate a correct installation in compliance with the rule of the art; - For the proper functioning of all system components, follow the instructions in the design, installation and user manuals provided by the manufacturer; - This outline may be amended by the Ariston Group at any time without prior notice. 4 9 11 10 18 16 A AB B 8 13 T 1 5 T 12 System Schematic 15 14 6 3 17 A AB B 7 LIGHT GATEWAY 2 RADS Designed by macrovector: www.freepik.com Ambitious, sustainable retrofit housing project sees Ariston NIMBUS heat pump installed. An Ariston NIMBUS Pocket air source heat pump has been supplied and fitted in a recently completed retrofit project in Leeds managed by IMS Heat Pumps and Canopy Housing. Project overview Canopy Housing is a grassroots, community retrofit and homelessness charity eco-renovating Victorian terraces in Leeds. It runs a volunteering programme that offers opportunities for the local community to learn retrofit skills and build professional relationships with a diverse group of people also living in the community. ‘Self-help’ is a key principle of the organisation, whereby those who are homeless, or at risk of homelessness, are given the opportunity to renovate their new home. IMS Heat Pumps is a specialist installer of both ground and air source heat pumps, covering Scotland, the North and the Midlands. Working together on sustainable heating options for the 3 bed, mid-terrace property, the Ariston NIMBUS Pocket 5kW ASHP was picked by IMS and Canopy Housing as the heat pump of choice against a series of considerations. KEY DATA Client: Sector: Project: Canopy Housing Housing Year: 2024 Technology: Product: Comment “ Replace existing gas heating system Air source heat pumps NIMBUS Pocket M NET R32 The Ariston Nimbus range has a very favourable Seasonal Coefficient of Performance (SCOP) of 4.08 with a predicted heat output of 4.08kWH from 1kWH of electricity to run the heat pump. The system installation cost was also a key factor and the Ariston range is competitive when compared to many other options available. ” Dave Richards, Technical Consultant, IMS Heat Pumps Ltd Sustainability and cost As a charitable organisation working with people who are often living in fuel poverty, Matilda Wallis at Canopy Housing said, “Staff have to balance sustainable heating options with eventual running costs. Currently, electricity tariffs are more costly than gas but ASHPs run on electricity meaning the most sustainable option isn’t always the cheapest to run.” Dave Richards, Technical Consultant with IMS explained why Canopy Housing and IMS agreed that NIMBUS was a good choice in this respect: “The Ariston Nimbus range has a very favourable Seasonal Coefficient of Performance (SCOP) of 4.08 with a predicted heat output of 4.08kWH from 1kWH of electricity to run the heat pump. This level of efficiency matched well with other heat pumps available which was an important consideration for Canopy Housing where a key consideration is in ensuring running costs are as low as possible for customers. The system installation cost was also a key factor and the Ariston range is competitive when compared to many other options available.” Featured product: NIMBUS Pocket M NET R32 The Ariston Nimbus Pocket ASHP was selected based on heat loss calculations and design parameters. It was installed alongside a 200 litre hot water cylinder for the provision of domestic hot water. This new heat pump is a cutting-edge solution for heating and cooling with high efficiency and low environmental footprint. Its design is the result of thorough consultation with professionals and is characterised by a number of innovative features that will make installation, set-up and maintenance easier than ever. Nimbus NET R32 is available in a large choice of configurations and sizes to meet diverse installation needs. / Eco Refrigerant R32 / COP up to 5.1 / Low noise levels up to 53 dB(A) / Power range between 1.7 to 17.7kW / Modern and innovative design / Sensys NET HD system interface and external heat regulation sensor included as standard / Remote management with the Ariston NET app / Completely installable outdoor / PV function | 1 | 2
Loading...
Loading...
CATALOGUE
PRODUCT BROCHURES
DATASHEETS
MANUALS
MANUALS (DISCONTINUED)
PLANNER MANUALS
CASE STUDIES