Views
3 years ago

Andris R - User & Installation Manual

  • Text
  • Valve
  • Discharge
  • Heater
  • Fitted
  • Mains
  • Tundish
  • Appliance
  • Electrical
  • Reducing
  • Anode
  • Andris
  • Manual

LEGIONELLA BACTERIA

LEGIONELLA BACTERIA FUNCTION Legionella are small rod shaped bacteria which are a natural constituent of all fresh waters. Legionaries’ disease is a pneumonia infection caused by inhaling of Legionella species. Long periods of water stagnation should be avoided; it means the water heater should be used or flushed at least weekly. The European standard CEN/TR 16355 gives recommendations for good practice concerning the prevention of Legionella growth in drinking water installations but existing national regulations remain in force. This electro-mechanical storage water heater is sold with a thermostat set at a temperature higher than 60°C; it means it is enabled to carry out a “thermal disinfection cycle” to restrict the Legionella growth inside the tank. Warning: water temperature in the tank can cause severe burns instantly. Children, disabled and elderly are at highest risk of being scalded. Feel water before bathing or showering. DESCRIPTION OF WATER HEATER 1) Hot water outlet (1/2” male BSP) 2) Temperature and pressure relief valve (30 litre only) 3) Cold water inlet (1/2” male BSP) 4) Control Immagini cover pagina 8 5) Regulation knob 6) Heating Immagini neon pagina 8 6

TECHNICAL SPECIFICATIONS For the technical specifications, refer to the nameplate (the nameplate is located next to the water intake/outlet pipes). Product information Product range 10 15 30 Weight (kg) 6,6 7,4 12,8 Installation Oversink Undersink Oversink Undersink Oversink Model Refer to the nameplate Qelec (kWh) 2,442 2,691 2,462 2,675 2,775 Load profile XXS S L wa wh 35,5% 32,9% 35,3% 33,0% 32,1% Capacity (l) 10 15 30 Heat loss 0,46 0,71 0,61 0,85 0,77 Heat up times (10-60°C) 20’ (*) 15’ (**) 20’ (*) 15’ (**) 26’ (*) 20’ (**) 26’ (*) 20’ (**) 35’ (**) Weights when full (kg) 17 17 23 23 43 Maximum inlet pressure Maximum operating pressure (*) 2000W (**) 3000W 15 dB 3,5 bar 6,5 bar The power consumption data in the table and the other information given in the Product Data Sheet (Enclosure A to this manual) are defined in relation to EU Directives 812/2013 and 814/2013. Products equipped with regulator knobs have the thermostat positioned in the setting condition at its set position shown in the Data Sheet (Enclosure A), used by the manufacturer to declare the appliance’s energy class. This appliance is conforming with the international electrical safety standards IEC 60335-1 and IEC 60335- 2-21. The CE marking of the appliances attests its conformity to the following EC Directives, of which it satisfies the essential requisites: - LVD Low Voltage Directive: EN 60335-1, EN 60335-2-21, EN 60529, EN 62233, EN 50106. - EMC Electro-Magnetic Compatibility: EN 55014-1, EN 55014-2, EN 61000-3-2, EN 61000-3-3. - RoHS2 Risk of Hazardous Substances: EN 50581. - ErP Energy related Products: EN 50440. - EN 12897:2016 7

MANUALS