MAINTENANCE GUIDE Pull the assembly towards you Remove the ceramic fibre. Remove the four screws and pull the burner toward you. Always replace the burner gasket (*). 4 6 (*) Remove the two screws and remove the electrode Verify and replace the other gaskets if they are damaged or showing signs of deterioration 4.3 Fan 4 Tools TIME 15 min Remove the silencer (see 4.3 - 1) Isolate the gas supply. Disconnect the gas pipe (see 4.3 - 2) 1 5 62 /

MAINTENANCE GUIDE Remove the three screws to free the fan. 4.4 Gas Valve Tools TIME 15 min Remove the two screws under the boiler and disconnect the gas pipe on the top of the gas valve 2 1 Remove the three nuts. Verify and replace the gasket if it’s damaged or showing signs of deterioration Remove the gas valve 3 2 2 3 Legend: 1 - Fan 2 - Venturi 3 - Gasket 1 GAS OUTLET Fan & mixer venturi according to the model Power Fan Venturi diameter 30 kW EBM 118 85W Ø 18,7 38 kW EBM 118 85W Ø 21,6 Legend: 1 - Inlet test point 1 / 63